Comparison of the standards for absorbed dose to water of the NMIJ and the BIPM for 60Co γ-ray beams

被引:4
|
作者
Kessler, C. [1 ]
Allisy-Roberts, P. J. [1 ]
Morishita, Y. [2 ]
Kato, M. [2 ]
Takata, N. [2 ]
Kurosawa, T. [2 ]
Tanaka, T. [2 ]
Saito, N. [2 ]
机构
[1] Bur Int Poids & Mesures, F-92312 Sevres, France
[2] AIST, Natl Metrol Inst Japan, Tsukuba, Ibaraki 3058568, Japan
关键词
D O I
10.1088/0026-1394/48/1A/06008
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A comparison of the standards for absorbed dose to water of the National Metrology Institute of Japan (NMIJ) and of the Bureau International des Poids et Mesures (BIPM) was carried out in the Co-60 gamma-ray reference beam of the BIPM in November to December 2009 under the auspices of the key comparison BIPM.RI(I)-K4. The comparison result, based on the calibration coefficients for two transfer standards and expressed as a ratio of the NMIJ and the BIPM standards for absorbed dose to water, is 0.9960 (46). The degrees of equivalence between the NMIJ and the other participants in this comparison have been calculated and the results are given in the form of a matrix for the ten national metrology institutes (NMIs) that have participated. A graphical presentation is also given.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Key comparison BIPM.RI(I)-K1 of the air-kerma standards of the NMIJ, Japan, and the BIPM in 60Co gamma radiation
    Bureau International des Poids et Mesures, Sèvres
    F-92312 Cedex, France
    不详
    305-8568, Japan
    [J]. Metrologia, 1 A
  • [32] Comparison of the standards for air kerma of the KRISS and the BIPM for 60Co gamma radiation
    Kessler, C.
    Yi, Chul-Young
    Chung, Jae-Pil
    Roger, P.
    Allisy-Roberts, P. J.
    [J]. METROLOGIA, 2010, 47
  • [33] Entrance Skin Dose by DAP Meter Calibrated Based on 60Co Absorbed Dose to Water for Diagnostic X-Ray Beams
    Umeno, S.
    Araki, F.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E596 - E597
  • [34] Bilateral comparison of the absorbed dose to water in high energy X-ray beams between the KRISS and the NMIJ
    Kim, In Jung
    Kim, Byoung Chul
    Yi, Chul-Young
    Shimizu, Morihito
    Morishita, Yuichiro
    Saito, Norio
    [J]. NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (07) : 1511 - 1516
  • [35] Comparison of the standards for air kerma of the VNIIM and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Oborin, A. V.
    Villevalde, A. Y.
    [J]. METROLOGIA, 2011, 48
  • [36] Comparison of the standards for air kerma of the NRC and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    McCaffrey, J. P.
    Ross, C. K.
    [J]. METROLOGIA, 2010, 47
  • [37] Comparison of the standards for air kerma of the ARPANSA and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Lye, J.
    Oliver, C.
    [J]. METROLOGIA, 2011, 48
  • [38] Comparison of the standards for air kerma of the NIST and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Minniti, Ronaldo
    [J]. METROLOGIA, 2013, 50
  • [39] Comparison of the standards for air kerma of the VSL and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    de Prez, L. A.
    van Dijk, E.
    [J]. METROLOGIA, 2010, 47
  • [40] Comparison of the standards for air kerma of the BEV and the BIPM for 60Co gamma radiation
    Kessler, C.
    Allisy-Roberts, P. J.
    Steurer, A.
    Baumgartner, A.
    Tiefenboeck, W.
    Gabris, F.
    [J]. METROLOGIA, 2010, 47