Correlations Between Digital Planimetry and Optical Coherence Tomography, Confocal Scanning Laser Ophthalmoscopy in Assessment of Optic Disc Parameters

被引:3
|
作者
Buteikiene, Dovile [1 ]
Paunksnis, Alvydas
Barzdziukas, Valerijus [1 ]
Zaliuniene, Dalia
Balciuniene, Iurate Vilma
Jegelevicius, Darius [2 ]
机构
[1] Lithuanian Univ Hlth Sci, Med Acad, Neurosci Inst, Dept Ophthalmol, Kaunas, Lithuania
[2] Kaunas Univ Technol, Inst Biomed Engn, Kaunas, Lithuania
来源
MEDICINA-LITHUANIA | 2012年 / 48卷 / 03期
关键词
optic disc; digital planimetry; optical coherence tomography; confocal scanning laser ophthalmoscopy; HEIDELBERG RETINA TOMOGRAPH; NERVE-FIBER LAYER; CUP/DISC RATIO; SIZE; AGREEMENT; GLAUCOMA; HEAD; INTRAOBSERVER; PHOTOGRAPHS; AREA;
D O I
10.3390/medicina48030021
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective and Aim. In routine clinical practice, laser methods for the evaluation of optic disc parameters are expensive and not accessible for all ophthalmologists; therefore, there is a need for less expensive technique. The aim of this study was to assess correlations between the parameters of the optic disc measured by digital planimetry (DP), optical coherence tomography (OCT), and con focal scanning laser ophthalmoscopy (CSLO) in healthy and glaucoma patients with the normal biometric parameters of the eye. Material and Methods. This case-control study enrolled 40 patients with glaucoma and 32 healthy patients with the normal biometric parameters of the eye. All subjects underwent full ophthalmologic examination, digital color optic disc photography, OCT, and CSLO at the same visit. The optic disc was morphometrically analyzed by DP. OCT, and CSLO. Seven optic disc parameters were evaluated. Results. In the glaucoma group, the optic disc and cup areas (r=0.7-0.8, P<0.001) and cup-to-optic disc and rim-to-optic disc area ratios (r=0.7, P<0.001) measured by DP were strongly correlated with those measured by OCT and CSLO, while the horizontal and vertical cup-to-optic disc diameter ratios were found to be moderately correlated (r=0.6-0.7, P<0.001). In healthy patients, the optic disc and cup areas were strongly correlated (r=0.7-8.0, P<0.001). Significant differences in all optic disc parameters, except for the optic disc area, measured by DP, OCT, and CSLO were found between glaucoma and healthy patients. Conclusions. Strong correlations between the parameters of the optic disc measured by DP, OCT, and CSLO were found. There were significant differences in the parameters between healthy and glaucoma eyes measured using DP; therefore, this technique may be used for diagnosis, management, and screening of glaucoma.
引用
收藏
页码:150 / 158
页数:9
相关论文
共 50 条
  • [21] Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage
    Kanamori, A
    Nagai-Kusuhara, A
    Escaño, MFT
    Maeda, H
    Nakamura, M
    Negi, A
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 244 (01) : 58 - 68
  • [22] Inter-observer variability of optic disc parameters measured by confocal scanning laser tomography
    Iester, MM
    Mikelberg, FS
    Courtright, P
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S72 - S72
  • [23] Comparison of confocal scanning laser ophthalmoscopy, scanning laser polarimetry and optical coherence tomography to discriminate ocular hypertension and glaucoma at an early stage
    Akiyasu Kanamori
    Azusa Nagai-Kusuhara
    Michael F. T. Escaño
    Hidetaka Maeda
    Makoto Nakamura
    Akira Negi
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2006, 244 : 58 - 68
  • [24] IOP fluctuation effects on scanning laser polarimetry with Variable Corneal Compensator, optical coherence tomography and confocal scanning laser ophthalmoscopy.
    Ajdelsztajn, T
    Tavares, IM
    Mello, PAA
    Galhardo, R
    Tanimoto, S
    Lottenberg, CL
    Paranhos, A
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U112 - U112
  • [25] Optic disc topographic parameters measured in the normal cynomolgus monkey by confocal scanning laser tomography
    Taniguchi, T
    Shimazawa, M
    Araie, M
    Tomita, G
    Sasaoka, M
    Kitazawa, Y
    Hara, H
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2005, 89 (08) : 1058 - 1062
  • [26] Optical Coherence Tomography, Scanning Laser Polarimetry and Confocal Scanning Laser Ophthalmoscopy in Retinal Nerve Fiber Layer Measurements of Glaucoma Patients
    Fanihagh, Farsad
    Kremmer, Stephan
    Anastassiou, Gerasimos
    Schallenberg, Maurice
    Steuhl, Klaus-Peter
    Selbach, Michael
    [J]. OPEN OPHTHALMOLOGY JOURNAL, 2015, 9 : 41 - 48
  • [27] Handheld simultaneous scanning laser ophthalmoscopy and optical coherence tomography system
    LaRocca, Francesco
    Nankivil, Derek
    Farsiu, Sina
    Izatt, Joseph A.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (11): : 2307 - 2321
  • [28] COMPARISON OF A NOVEL CONFOCAL SCANNING LASER OPHTHALMOSCOPY ALGORITHM WITH OPTICAL COHERENCE TOMOGRAPHY IN MEASUREMENT OF MACULAR THICKNESS AND VOLUME
    Lee, Byung Ro
    Bartsch, Dirk-Uwe
    Kozak, Igor
    Cheng, Lingyun
    Freeman, William R.
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2009, 29 (09): : 1328 - 1334
  • [29] A COMPARISON OF OPHTHALMOSCOPIC BIOMETRY, PHOTOGRAPHIC PLANIMETRY AND SCANNING LASER TOMOGRAPHY IN MEASUREMENT OF THE OPTIC DISC
    MONTGOMERY, DM
    KONIGSREUTHER, KA
    JONAS, JB
    KIRKNESS, CM
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1344 - 1344
  • [30] Detection of glaucomatous optic disc hemorrhages by confocal scanning laser tomography
    Dichtl, A
    Jonas, JB
    Mardin, CY
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1997, 115 (06) : 800 - 801