Flexural Properties of Native and Tissue-Engineered Human Septal Cartilage

被引:9
|
作者
Caffrey, Jason P. [1 ]
Kushnaryov, Anton M. [2 ,3 ]
Reuther, Marsha S. [2 ,3 ]
Wong, Van W. [1 ,4 ]
Briggs, Kristen K. [1 ,4 ]
Masuda, Koichi [5 ]
Sah, Robert L. [1 ,6 ]
Watson, Deborah [2 ,3 ]
机构
[1] Univ Calif San Diego, Dept Bioengn, La Jolla, CA 92093 USA
[2] VA San Diego Healthcare Syst, Head & Neck Surg Sect, San Diego, CA USA
[3] Univ Calif San Diego, Div Otolaryngol Head & Neck Surg, La Jolla, CA 92093 USA
[4] VA San Diego Healthcare Syst, Res Serv, San Diego, CA USA
[5] Univ Calif San Diego, Dept Orthoped Surg, La Jolla, CA 92093 USA
[6] Univ Calif San Diego, Inst Engn Med, La Jolla, CA 92093 USA
关键词
bending modulus; septal cartilage; tissue engineering; BIOMECHANICAL PROPERTIES; RHINOPLASTY; BEHAVIOR;
D O I
10.1177/0194599812474228
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective. To determine and compare the bending moduli of native and engineered human septal cartilage. Study Design. Prospective, basic science. Setting. Research laboratory. Subjects and Methods. Neocartilage constructs were fabricated from expanded human septal chondrocytes cultured in differentiation medium for 10 weeks. Constructs (n = 10) and native septal cartilage (n = 5) were tested in a 3-point bending apparatus, and the bending moduli were calculated using Euler-Bernoulli beam theory. Results. All samples were tested successfully and returned to their initial shape after unloading. The bending modulus of engineered constructs (0.32 +/- 0.25 MPa, mean +/- SD) was 16% of that of native septal cartilage (1.97 +/- 1.25 MPa). Conclusion. Human septal constructs, fabricated from cultured human septal chondrocytes, are more compliant in bending than native human septal tissue. The bending modulus of engineered septal cartilage can be measured, and this modulus provides a useful measure of construct rigidity while undergoing maturation relative to native tissue.
引用
收藏
页码:576 / 581
页数:6
相关论文
共 50 条
  • [41] Usefulness of photoacoustic measurements for evaluation of biomechanical properties of tissue-engineered cartilage
    Ishihara, M
    Sato, M
    Sato, S
    Kikuchi, T
    Mochida, J
    Kikuchi, M
    TISSUE ENGINEERING, 2005, 11 (7-8): : 1234 - 1243
  • [42] Hyaluronic Acid Enhances the Mechanical Properties of Tissue-Engineered Cartilage Constructs
    Levett, Peter A.
    Hutmacher, Dietmar W.
    Malda, Jos
    Klein, Travis J.
    PLOS ONE, 2014, 9 (12):
  • [43] Comments on: "Quantitative Evaluation of Mechanical Properties in Tissue-Engineered Auricular Cartilage"
    Hong, Paul
    Gratzer, Paul F.
    Bezuhly, Michael
    TISSUE ENGINEERING PART B-REVIEWS, 2015, 21 (02) : 242 - 243
  • [44] Digoxin and Adenosine Triphosphate Enhance the Functional Properties of Tissue-Engineered Cartilage
    Makris, Eleftherios A.
    Huang, Brian J.
    Hu, Jerry C.
    Chen-Izu, Ye
    Athanasiou, Kyriacos A.
    TISSUE ENGINEERING PART A, 2015, 21 (5-6) : 884 - 894
  • [45] Behavior of tissue-engineered human cartilage after transplantation into nude mice
    Rotter, N
    Aigner, J
    Naumann, A
    Hammer, C
    Sittinger, M
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1999, 10 (10-11) : 689 - 693
  • [46] Behavior of tissue-engineered human cartilage after transplantation into nude mice
    N. Rotter
    J. Aigner
    A. Naumann
    C. Hammer
    M. Sittinger
    Journal of Materials Science: Materials in Medicine, 1999, 10 : 689 - 693
  • [47] Development of Bone and Cartilage in Tissue-Engineered Human Middle Phalanx Models
    Wada, Yoshitaka
    Enjo, Mitsuhiro
    Isogai, Noritaka
    Jacquet, Robin
    Lowder, Elizabeth
    Landis, William J.
    TISSUE ENGINEERING PART A, 2009, 15 (12) : 3765 - 3778
  • [48] Subcutaneous Implants Coated with Tissue-Engineered Cartilage
    Kim, Soo Whan
    Dobratz, Eric J.
    Ballert, John A.
    Voglewede, Andrew T.
    Park, Stephen S.
    LARYNGOSCOPE, 2009, 119 (01): : 62 - 66
  • [49] FORMATION OF TISSUE-ENGINEERED CONSTRUCT OF CARTILAGE IN VITRO
    Surguchenko, V. A.
    Ponomareva, A. S.
    Kirsanova, L. A.
    Bubentsova, G. N.
    Skaletskij, N. N.
    Sevastianov, V. I.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2013, 15 (03): : 66 - 72
  • [50] TISSUE-ENGINEERED CARTILAGE REPAIR IN AN EXPERIMENTAL MODEL
    Robla Costales, D.
    Meana Infiesta, A.
    Alvarez Garcia, R.
    Robla Costales, J.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 17 - 18