An ion Doppler spectrometer instrument for ion temperature and flow measurements on SSPX

被引:10
|
作者
King, J. D. [1 ]
McLean, H. S. [1 ]
Wood, R. D. [1 ]
Romero-Talamas, C. A. [1 ]
Moller, J. M. [1 ]
Morse, E. C. [2 ]
机构
[1] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[2] Univ Calif Berkeley, Berkeley, CA 94720 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2008年 / 79卷 / 10期
关键词
discharges (electric); Doppler broadening; flow measurement; helium; hydrogen; optical fibres; photomultipliers; plasma diagnostics; plasma flow; plasma temperature;
D O I
10.1063/1.2957842
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-resolution ion Doppler spectrometer (IDS) has been installed on the sustained spheromak plasma experiment to measure ion temperatures and plasma flow. The system is composed of a 1 m focal length Czerny-Turner spectrometer with a diffraction grating line density of 2400 lines/mm, which allows for first order spectra between 300 and 600 nm. A 16-channel photomultiplier tube detection assembly combined with output coupling optics provides a spectral resolution of 0.0126 nm/channel. We calculate in some detail the mapping of curved slit images onto the linear detector array elements. This is important in determining the wavelength resolution and setting the optimum vertical extent of the slit. Also, because of the small wavelength window of the IDS, a miniature fiber-optic survey spectrometer sensitive to a wavelength range 200-1100 nm and having a resolution of 0.2 nm is used to obtain a time-integrated spectrum for each shot to verify specific impurity line radiation. Several measurements validate the systems operation. Doppler broadening of C III 464.72 nm line in the plasma shows time-resolved ion temperatures up to 250 eV for hydrogen discharges, which is consistent with neutral particle energy analyzer measurements. Flow measurements show a sub-Alfvenic plasma flow ranging from 5 to 45 km/s for helium discharges.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Measurements of ion temperature and flow velocity in a plasma with a linear magnetic field configuration
    Jensen, O
    CONTRIBUTIONS TO PLASMA PHYSICS, 2002, 42 (05) : 526 - 536
  • [22] Simultaneous measurements of plasma flow and ion temperature using the asymmetric double probe
    Maeda, M
    Uehara, K
    Amemiya, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 1997, 36 (11): : 6992 - 6993
  • [23] Simultaneous measurements of plasma flow and ion temperature using the asymmetric double probe
    Japan Science and Technology Corp, Saitama, Japan
    Japanese Journal of Applied Physics, Part 1: Regular Papers & Short Notes & Review Papers, 1997, 36 (11): : 6992 - 6993
  • [24] Enabling Isotope Ratio Measurements on an Ion Trap Mass Spectrometer
    Vazquez, Timothy
    Taylor, Colette
    Knowlton, Maverick
    Williams, Sean
    Evans-Nguyen, Theresa
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2020, 31 (08) : 1722 - 1729
  • [25] A multipurpose electron-ion spectrometer for measurements with synchrotron radiation
    Huttula, M
    Harkoma, M
    Nommiste, E
    Aksela, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 (PART II): : 1514 - 1518
  • [26] MASS-SPECTROMETER FOR MEASUREMENTS OF RELATIVE ION CONCENTRATIONS IN PLASMAS
    SUSZCYNSKY, DM
    DANGELO, N
    MERLINO, RL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1988, 59 (08): : 1376 - 1379
  • [27] Coherence imaging for ion temperature and flow measurements in a low-temperature helicon plasma source
    Lester, R.
    Zhai, Y.
    Corr, C.
    Howard, J.
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2016, 25 (01):
  • [28] ION SOURCES FOR HIGH-TEMPERATURE MEASUREMENTS USING THE MI-1201 MASS-SPECTROMETER
    KARASEV, NM
    MINAEVA, II
    VARKOV, MV
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1983, 26 (01) : 164 - 167
  • [29] MEASUREMENTS OF ION TEMPERATURE AND COMPOSITION WITH A PLANAR ION TRAP IN OGO 6
    SANATANI, S
    HANSON, WB
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1969, 50 (11): : 652 - &
  • [30] Electron monochromator mass spectrometer instrument for negative ion analysis of electronegative compounds
    Laramee, JA
    Mazurkiewicz, P
    Berkout, V
    Deinzer, ML
    MASS SPECTROMETRY REVIEWS, 1996, 15 (01) : 15 - 42