Experimental studies on few-view reconstruction for high-resolution micro-CT

被引:16
|
作者
Sen Sharma, Kriti [1 ]
Jin, Xin [2 ]
Holzner, Christian [3 ]
Narayanan, Shree [1 ]
Liu, Baodong [4 ]
Wang, Dong [5 ]
Agah, Masoud [1 ]
Wang, Libing [5 ]
Yu, Hengyong [4 ]
Wang, Ge [6 ]
机构
[1] Virginia Tech, Dept Elect & Comp Engn, Blacksburg, VA USA
[2] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
[3] Xradia Inc, Pleasanton, CA USA
[4] Wake Forest Univ Hlth Sci, VT WFU Sch Biomed Engn & Sci, Biomed Imaging Div, Winston Salem, NC USA
[5] Virginia Tech, Dept Civil & Environm Engn, Blacksburg, VA USA
[6] Rensselaer Polytech Inst, Biomed Imaging Ctr, Troy, NY USA
关键词
Few-view reconstruction; micro-CT; compressed sensing; TV minimization; SART-TV; COMPUTED-TOMOGRAPHY; IMAGE-RECONSTRUCTION; FAN-BEAM; ALGORITHM;
D O I
10.3233/XST-130364
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
High-resolution micro-CT offers 3D non-destructive imaging but scan times are prohibitively large in many cases. Advancements in image reconstruction offer great reduction in number of views while maintaining reconstruction accuracy; yet filtered back projection remains the de facto standard. An extensive study of few-view reconstruction using compressed-sensing based iterative techniques is carried out. Also, a novel 3D micro-CT phantom is proposed, and used for analyzing reconstruction accuracy. Numerical tests, and studies on real micro-CT data show that if measurement noise in projections is not extremely high, the number of views may be reduced to 1/8th of the typically acquired view numbers. The study motivates the adoption of advanced reconstruction techniques to allow faster scanning, lower dosage, and reduced data size in high-resolution micro-CT.
引用
收藏
页码:25 / 42
页数:18
相关论文
共 50 条
  • [31] A preliminary investigation of using prior information for potentially improving image reconstruction in few-view CT
    Cho, Seungryong
    Sidky, Emil Y.
    Bian, Junguo
    Pelizzari, Charles A.
    Pan, Xiaochuan
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [32] Image reconstruction from few-view CT data by gradient-domain dictionary learning
    Hu, Zhanli
    Liu, Qiegen
    Zhang, Na
    Zhang, Yunwan
    Peng, Xi
    Wu, Peter Z.
    Zheng, Hairong
    Liang, Dong
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2016, 24 (04) : 627 - 638
  • [33] High resolution CT and Micro-CT in Vienna's Osteology
    Resch, Heinrich
    [J]. OSTEOLOGIE, 2013, 22 (01) : 5 - 5
  • [34] Prior Image based Anisotropic Edge Guided TV Minimization for Few-View CT Reconstruction
    Rong, Junyan
    Gao, Peng
    Liu, Wenlei
    Liao, Qimei
    Jiao, Chun
    Lu, Hongbing
    [J]. 2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [35] Few-View CT Image Reconstruction via Least-Squares Methods: Assessment and Optimization
    Perez, Monica Chillaron
    Vidal, Vicente E.
    Verdu, Gumersindo J.
    Quintana-Orti, Gregorio
    [J]. NUCLEAR SCIENCE AND ENGINEERING, 2024, 198 (02) : 193 - 206
  • [36] Deep Efficient End-to-End Reconstruction (DEER) Network for Few-View Breast CT Image Reconstruction
    Xie, Huidong
    Shan, Hongming
    Cong, Wenxiang
    Liu, Chi
    Zhang, Xiaohua
    Liu, Shaohua
    Ning, Ruola
    Wang, Ge
    [J]. IEEE ACCESS, 2020, 8 : 196633 - 196646
  • [37] ANALYSIS OF PROJECTION GEOMETRY FOR FEW-VIEW RECONSTRUCTION OF SPARSE OBJECTS
    HENRI, CJ
    COLLINS, DL
    PETERS, TM
    [J]. MEDICAL PHYSICS, 1993, 20 (05) : 1537 - 1547
  • [38] Few-view image reconstruction combining total variation and a high-order norm
    Zhang, Yi
    Zhang, Wei-Hua
    Chen, Hu
    Yang, Meng-Long
    Li, Tai-Yong
    Zhou, Ji-Liu
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2013, 23 (03) : 249 - 255
  • [39] Anatomic Comparison of Contralateral Maxillary Second Molars Using High-Resolution Micro-CT
    Dandache, Ghassan
    Aksoy, Umut
    Ozel, Mehmet Birol
    Orhan, Kaan
    [J]. SYMMETRY-BASEL, 2023, 15 (02):
  • [40] Computational biomechanics of the distal tibia from high-resolution MR and micro-CT images
    Rajapakse, Chamith S.
    Magland, Jeremy F.
    Wald, Michael J.
    Liu, X. Sherry
    Zhang, X. Henry
    Guo, X. Edward
    Wehrli, Felix W.
    [J]. BONE, 2010, 47 (03) : 556 - 563