Steering an Actuated-Tip Needle in Biological Tissue: Fusing FBG-Sensor Data and Ultrasound Images

被引:0
|
作者
Shahriari, Navid [1 ,2 ]
Roesthuis, Roy J. [1 ]
van de Berg, Nick J. [3 ]
van den Dobbelsteen, John J. [3 ]
Misra, Sarthak [1 ,2 ]
机构
[1] Univ Twente, MIRA Inst Biomed Technol & Tech Med, Dept Biomech Engn, Surg Robot Lab, POB 217, NL-7500 AE Enschede, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Ctr Med Imaging North East Netherlands, NL-9700 AB Groningen, Netherlands
[3] Delft Univ Technol, Dept Biomech Engn 3mE, NL-2600 AA Delft, Netherlands
关键词
DESIGN; BIOPSY; SYSTEM;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Needle insertion procedures are commonly performed in current clinical practice for diagnostic and therapeutic purposes. Although prevailing technology allows accurate localization of lesions, they cannot yet be precisely targeted. Needle steering is a promising technique to overcome this challenge. In this paper, we describe the development of a novel steering system for an actuated-tip flexible needle. Strain measurements from an array of Fiber Bragg Grating (FBG) sensors are used for online reconstruction of the needle shape in 3D-space. FBG-sensor data is then fused with ultrasound images obtained from a clinically-approved Automated Breast Volume Scanner (ABVS) using an unscented Kalman filter. A new ultrasound-based tracking algorithm is developed for the robust tracking of the needle in biological tissue. Two experimental cases are presented to evaluate the proposed steering system. In the first case, the needle shape is reconstructed using the tracked tip position in ultrasound images and FBG-sensor measurements, separately. The reconstructed shape is then compared with the actual 3D needle shape obtained from the ABVS. In the second case, two steering experiments are performed to evaluate the overall system by fusing the FBG-sensor data and ultrasound images. Average targeting errors are 1.29 +/- 0.41 mm and 1.42 +/- 0.72 mm in gelatin phantom and biological tissue, respectively.
引用
收藏
页码:4443 / 4449
页数:7
相关论文
共 14 条
  • [1] Modeling and Steering of a Novel Actuated-Tip Needle through a Soft-Tissue Simulant using Fiber Bragg Grating Sensors
    Roesthuis, Roy J.
    van de Berg, Nick J.
    van den Dobbelsteen, John J.
    Misra, Sarthak
    2015 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2015, : 2283 - 2289
  • [2] Computed tomography (CT)-compatible remote center of motion needle steering robot: Fusing CT images and electromagnetic sensor data
    Shahriari, Navid
    Heerink, Wout
    van Katwijk, Tim
    Hekman, Edsko
    Oudkerk, Matthijs
    Misra, Sarthak
    MEDICAL ENGINEERING & PHYSICS, 2017, 45 : 71 - 77
  • [3] Needle Steering in Biological Tissue using Ultrasound-based Online Curvature Estimation
    Moreira, Pedro
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    2014 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2014, : 4368 - 4373
  • [4] 3-D Ultrasound-Guided Robotic Needle Steering in Biological Tissue
    Adebar, Troy K.
    Fletcher, Ashley E.
    Okamura, Allison M.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (12) : 2899 - 2910
  • [5] Ultrasound-guided three-dimensional needle steering in biological tissue with curved surfaces
    Abayazid, Momen
    Moreira, Pedro
    Shahriari, Navid
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    MEDICAL ENGINEERING & PHYSICS, 2015, 37 (01) : 145 - 150
  • [6] Flexible Needle Steering in Moving Biological Tissue With Motion Compensation Using Ultrasound and Force Feedback
    Chevrie, Jason
    Shahriari, Navid
    Babel, Marie
    Krupa, Alexandre
    Misra, Sarthak
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2018, 3 (03): : 2338 - 2345
  • [7] Experimental evaluation of ultrasound-guided 3D needle steering in biological tissue
    Abayazid, Momen
    Vrooijink, Gustaaf J.
    Patil, Sachin
    Alterovitz, Ron
    Misra, Sarthak
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (06) : 931 - 939
  • [8] Experimental evaluation of ultrasound-guided 3D needle steering in biological tissue
    Momen Abayazid
    Gustaaf J. Vrooijink
    Sachin Patil
    Ron Alterovitz
    Sarthak Misra
    International Journal of Computer Assisted Radiology and Surgery, 2014, 9 : 931 - 939
  • [9] Semi-Automated Needle Steering in Biological Tissue Using an Ultrasound-Based Deflection Predictor
    Mohsen Khadem
    Carlos Rossa
    Nawaid Usmani
    Ron S. Sloboda
    Mahdi Tavakoli
    Annals of Biomedical Engineering, 2017, 45 : 924 - 938
  • [10] Semi-Automated Needle Steering in Biological Tissue Using an Ultrasound-Based Deflection Predictor
    Khadem, Mohsen
    Rossa, Carlos
    Usmani, Nawaid
    Sloboda, Ron S.
    Tavakoli, Mahdi
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (04) : 924 - 938