Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray microbeam

被引:52
|
作者
Graceffa, Rita [1 ,2 ]
Nobrega, R. Paul [3 ]
Barrea, Raul A. [1 ,2 ]
Kathuria, Sagar V. [3 ]
Chakravarthy, Srinivas [1 ,2 ]
Bilsel, Osman [3 ]
Irving, Thomas C. [1 ,2 ]
机构
[1] IIT, CSRRI, BioCAT, Chicago, IL 60616 USA
[2] IIT, Dept BCS, Chicago, IL 60616 USA
[3] Univ Massachusetts, Sch Med, Dept Biochem & Mol Pharmacol, Worcester, MA 01605 USA
基金
美国国家卫生研究院;
关键词
micro-SAXS; time-resolved; protein folding; PROTEIN-FOLDING KINETICS; CYTOCHROME-C; EARLY EVENTS; MICROSECOND; SCATTERING; SPECTROSCOPY; LANDSCAPE;
D O I
10.1107/S0909049513021833
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Small-angle X-ray scattering (SAXS) is a well established technique to probe the nanoscale structure and interactions in soft matter. It allows one to study the structure of native particles in near physiological environments and to analyze structural changes in response to variations in external conditions. The combination of microfluidics and SAXS provides a powerful tool to investigate dynamic processes on a molecular level with sub-millisecond time resolution. Reaction kinetics in the sub-millisecond time range has been achieved using continuous-flow mixers manufactured using micromachining techniques. The time resolution of these devices has previously been limited, in part, by the X-ray beam sizes delivered by typical SAXS beamlines. These limitations can be overcome using optics to focus X-rays to the micrometer size range providing that beam divergence and photon flux suitable for performing SAXS experiments can be maintained. Such micro-SAXS in combination with microfluidic devices would be an attractive probe for time-resolved studies. Here, the development of a high-duty-cycle scanning microsecond-time-resolution SAXS capability, built around the Kirkpatrick-Baez mirror-based microbeam system at the Biophysics Collaborative Access Team (BioCAT) beamline 18ID at the Advanced Photon Source, Argonne National Laboratory, is reported. A detailed description of the microbeam small-angle-scattering instrument, the turbulent flow mixer, as well as the data acquisition and control and analysis software is provided. Results are presented where this apparatus was used to study the folding of cytochrome c. Future prospects for this technique are discussed.
引用
收藏
页码:820 / 825
页数:6
相关论文
共 50 条
  • [21] Mapping Enzyme Motions in Real Time Using Time-Resolved Temperature-Jump X-Ray Crystallography and SAXS/WAXS
    Thompson, Michael
    Wolff, Alexander
    Barad, Benjamin
    Nango, Eriko
    Kubo, Minoru
    Sugahara, Michihiro
    Cho, Hynu Sun
    Brewster, Aaron
    Young, Iris
    Schotte, Friedrich
    Tanaka, Rie
    Tono, Kensuke
    Iwata, So
    Sauter, Nicholas
    Anfinrud, Philip
    Fraser, James
    PROTEIN SCIENCE, 2018, 27 : 71 - 71
  • [22] An X-ray Chopper for Time-resolved Crystallography
    Husheer, Shamus
    Bowes, Katharine
    Cole, Jacqueline
    Rayment, Trevor
    Teat, Simon
    Warren, John
    Bushnell-Wye, Graham
    Raithby, Paul
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2005, 61 : C136 - C136
  • [23] On the theory of time-resolved X-ray diffraction
    Henriksen, Niels E.
    Moller, Klaus B.
    JOURNAL OF PHYSICAL CHEMISTRY B, 2008, 112 (02): : 558 - 567
  • [24] Hemoprotein time-resolved X-ray crystallography
    Milani, Mario
    Nardini, Marco
    Pesce, Alessandra
    Mastrangelo, Eloise
    Bolognesi, Martino
    IUBMB LIFE, 2008, 60 (03) : 154 - 158
  • [25] Ultrafast time-resolved X-ray diffraction
    Sokolowski-Tinten, K
    Blome, C
    Blums, J
    Cavalleri, A
    Dietrich, C
    Tarasevitch, A
    von der Linde, D
    SCIENCE OF SUPERSTRONG FIELD INTERACTIONS, 2002, 634 : 11 - 18
  • [26] Time-resolved X-ray absorption spectroscopy
    Bressler, Christian
    Chergui, Majed
    ACTUALITE CHIMIQUE, 2008, (317): : 59 - 61
  • [27] Time-resolved nanocrystallography with X-ray lasers
    Spence, John C. H.
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2011, 67 : C5 - C5
  • [28] Time-resolved fluorescent X-ray interference
    Sasaki, YC
    Suzuki, Y
    Yamanashi, H
    Arai, A
    Yanagihara, M
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1075 - 1078
  • [29] Development of time-resolved X-ray spectrometer
    Miura, E.
    Shinbo, M.
    Owadano, Y.
    Denshi Gijutsu Sogo Kenkyusho Iho/Bulletin of the Electrotechnical Laboratory, 1997, 61 (03): : 51 - 56
  • [30] Time-resolved hard x-ray spectrometer
    Moy, Kenneth
    Cuneo, Michael
    McKenna, Ian
    Keenan, Thomas
    Sanford, Thomas
    Mock, Ray
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS AND PENETRATING RADIATION SYSTEMS VIII, 2006, 6319