Efficient reconstruction from truncated data in circular cone-beam CT

被引:5
|
作者
Wang Xian-Chao [1 ]
Yan Bin [1 ]
Liu Hong-Kui [2 ]
Li Lei [1 ]
Wei Xing [1 ]
Hu Guo-En [1 ]
机构
[1] Natl Digital Switching Syst Engn & Technol Res Ct, Zhengzhou 450002, Peoples R China
[2] Dalian Univ Technol, Fac Infrastruct Engn, Dalian 116000, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
X-ray optics; CT; image reconstruction; GPU; IMAGE-RECONSTRUCTION; FILTERED-BACKPROJECTION; HILBERT TRANSFORM; MINIMUM DATA; PI-LINES; ALGORITHMS; PROJECTIONS; REGION;
D O I
10.7498/aps.62.098702
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In circular cone-beam computed tomography (CT), to solve the 3D image reconstruction from truncated projection data which has no truncation along PI-line, backprojection-filtration (BPF) algorithm is a preferred choice. However, in its performance the integral interval of backprojection is variable for different PI-line, rendering the parallelism performance of backprojection low. So it cannot satisfy the requirement of fast image reconstruction in practical CT system. In this paper, a tent BPF (T-BPF) algorithm is developed based on the data rebinning method, which was performed by first rearranging the cone-beam data to tent-like parallel-beam data, and then applying the proposed BPF-type algorithm to reconstruct images from the rearranged data. T-BPF turns the variable view-angle integral interval of backprojection into a fixed integral interval, and there are no relations in the loops of backprojection calculation, which means the parallelism performance of T-BPF is an improvement over that of the original BPF algorithm. The results of experiments show that compared with the conventional CPU implementation, the GPU accelerated method provides images of the same quality with a speedup factor 1036 for the reconstruction of 256(3) Shepp-Logan model. The speedup factor is an improvement in the original BPF algorithm. T-BPF provides a solution for the 3D fast reconstruction from truncated data.
引用
收藏
页数:7
相关论文
共 27 条
  • [1] Cho SR, 2006, IEEE NUCL SCI CONF R, P2889
  • [2] Quantitative reconstruction from truncated projections in classical tomography
    Clackdoyle, R
    Noo, F
    Guo, JY
    Roberts, JA
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2570 - 2578
  • [3] Fan-beam filtered-backprojection reconstruction without backprojection weight
    Dennerlein, Frank
    Noo, Frederic
    Hornegger, Joachim
    Lauritsch, Guenter
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (11): : 3227 - 3240
  • [4] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [5] 3D cone-beam CT reconstruction for circular trajectories
    Grass, M
    Köhler, T
    Proksa, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (02): : 329 - 347
  • [6] Algorithm-Enabled Low-Dose Micro-CT Imaging
    Han, Xiao
    Bian, Junguo
    Eaker, Diane R.
    Kline, Timothy L.
    Sidky, Emil Y.
    Ritman, Erik L.
    Pan, Xiaochuan
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (03) : 606 - 620
  • [7] Han Y, 2012, CHIN PHYS B, V21
  • [8] Jia PX, 2010, CHINESE PHYS B, V19, DOI 10.1088/1674-1056/19/8/087802
  • [9] Li L, 2008, IEEE NUCL SCI S MED
  • [10] Reduction of aliasing artifact in Micro CT
    Luo Zhao-Yang
    Yang Xiao-Quan
    Meng Yuan-Zheng
    Deng Yong
    [J]. ACTA PHYSICA SINICA, 2010, 59 (11) : 8237 - 8243