Quantifying the impact of underlying measurement error on cervical spinal cord diffusion tensor imaging at 3T

被引:11
|
作者
By, Samantha [1 ,2 ]
Smith, Alex K. [1 ,2 ]
Dethrage, Lindsey M. [2 ,3 ]
Lyttle, Bailey D. [2 ]
Landman, Bennett A. [1 ,2 ,3 ,4 ]
Creasy, Jeffrey L. [3 ]
Pawate, Siddharama [5 ]
Smith, Seth A. [1 ,2 ,3 ]
机构
[1] Vanderbilt Univ, Dept Biomed Engn, Nashville, TN 37235 USA
[2] Vanderbilt Univ, Inst Imaging Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Vanderbilt Univ, Dept Radiol & Radiol Sci, 221 Kirkland Hall, Nashville, TN 37235 USA
[4] Vanderbilt Univ, Dept Elect Engn, Nashville, TN 37235 USA
[5] Vanderbilt Univ, Dept Neurol, 221 Kirkland Hall, Nashville, TN 37235 USA
关键词
spinal cord; magnetic resonance imaging; diffusion tensor imaging; PRINCIPAL EIGENVECTOR MEASUREMENTS; FRACTIONAL ANISOTROPY; GRADIENT DIRECTIONS; MEAN DIFFUSIVITY; HUMAN BRAIN; MRI; NOISE; SCHEMES; INJURY; DTI;
D O I
10.1002/jmri.25308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo empirically characterize and quantify the impact of gradient weighting schemes on the appearance and fidelity of diffusion tensor imaging of the human spinal cord in vivo in clinically relevant scan time equivalents (STE). Materials and MethodsIn five healthy controls at 3T, we evaluated test-retest reproducibility and performed voxelwise analysis of diffusion tensor imaging (DTI)-derived indices (fractional anisotropy [FA], mean [MD], axial [AD], and radial [RD] diffusivity) in the cervical spinal cord to assess spatial dependencies of measurement error and differences across three different sampling schemes (6, 15, and 32 directions) at STE of 4.5, 9, and 18 minutes. A subjective assessment was also performed. ResultsWith six directions, column-specific errors are highest (effect size=2.9%, 4.4%, 7.2% for FA in dorsal column, lateral column, and gray matter) and different than the 15-direction scheme (P < 0.05). STE sequences with 15 and 32 directions exhibited small differences in error (P > 0.05). For FA and AD, measurement errors are prevalent in gray matter, while partial volume effects with cerebrospinal fluid heavily influence RD. Measurement errors decreased with increasing scan time (P < 0.01), albeit with diminishing returns at scan times longer than 9 minutes (P < 0.05). ConclusionA 15-direction scheme of 9 minutes yields measurements of the cervical spinal cord with low error. J. Magn. Reson. Imaging 2016;44:1608-1618.
引用
收藏
页码:1608 / 1618
页数:11
相关论文
共 50 条
  • [31] Diffusion imaging of the cervical spinal cord
    Shimony, JS
    Ojemann, JG
    Akbudak, E
    Snyder, AZ
    Lauryssen, C
    Conturo, TE
    [J]. RADIOLOGY, 1998, 209P : 393 - 393
  • [32] Quantitative assessment of cervical spinal cord by diffusion tensor tractography in 3.0 T
    Onder Turna
    Isil Fazilet Turna
    [J]. La radiologia medica, 2021, 126 : 83 - 88
  • [33] Quantitative assessment of cervical spinal cord by diffusion tensor tractography in 3.0 T
    Turna, Onder
    Turna, Isil Fazilet
    [J]. RADIOLOGIA MEDICA, 2021, 126 (01): : 83 - 88
  • [34] Diffusion tensor imaging of cervical spinal cord: A quantitative diagnostic tool in cervical spondylotic myelopathy
    Toktas, Zafer Orkun
    Tanrikulu, Bahattin
    Koban, Orkun
    Kilic, Turker
    Konya, Deniz
    [J]. JOURNAL OF CRANIOVERTEBRAL JUNCTION AND SPINE, 2016, 7 (01): : 26 - 30
  • [35] Diffusion tensor imaging in spinal cord compression
    Wang, Wei
    Qin, Wen
    Hao, Nanxin
    Wang, Yibin
    Zong, Genlin
    [J]. ACTA RADIOLOGICA, 2012, 53 (08) : 921 - 928
  • [36] Intersite Reliability of Diffusion Tensor Imaging on Two 3T Scanners
    Kamagata, Koji
    Shimoji, Keigo
    Hori, Masaaki
    Nishikori, Akira
    Tsuruta, Kohei
    Yoshida, Mariko
    Kamiya, Kouhei
    Irie, Ryusuke
    Suzuki, Michimasa
    Kyogoku, Shinsuke
    Suzuki, Yuriko
    Sato, Noriko
    Aoki, Shigeki
    [J]. MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (03) : 227 - 233
  • [37] Normal Values of Diffusion Tensor Magnetic Resonance Imaging Parameters in the Cervical Spinal Cord
    Chagawa, Kazuki
    Nishijima, Shunka
    Kanchiku, Tsukasa
    Imajo, Yasuaki
    Suzuki, Hidenori
    Yoshida, Yuichiro
    Taguchi, Toshihiko
    [J]. ASIAN SPINE JOURNAL, 2015, 9 (04) : 541 - 547
  • [38] A systematic review of repeatability and reproducibility studies of diffusion tensor imaging of cervical spinal cord
    Al-Shaari, Hussein
    Fulford, J.
    Meertens, R.
    Heales, C. J.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1151):
  • [39] A meta-analysis of the role of diffusion tensor imaging in cervical spinal cord compression
    Ouyang, Ziqiang
    Zhang, Na
    Li, Meihua
    Hong, Tao
    Ouyang, Taohui
    Meng, Wei
    [J]. JOURNAL OF NEUROIMAGING, 2023, 33 (04) : 493 - 500
  • [40] Specific microstructural changes of the cervical spinal cord in syringomyelia estimated by diffusion tensor imaging
    Weifei Wu
    Xiangxiang Li
    Zong Yang
    Neng Ru
    Fan Zhang
    Jie Liang
    Ke Zhang
    [J]. Scientific Reports, 11