Thermodynamic analysis of three ejector based organic flash cycles for low grade waste heat recovery

被引:30
|
作者
Chen, Long Xiang [1 ]
Hu, Peng [2 ]
Sheng, Chun Chen [3 ]
Zhang, Nan [2 ]
Xie, Mei Na [1 ]
Wang, Feng Xiang [1 ]
机构
[1] Chinese Acad Sci, Quanzhou Inst Equipment Mfg, Haixi Inst, Jinjiang 362200, Peoples R China
[2] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230027, Anhui, Peoples R China
[3] 16th Inst China Elect Technol Grp Corp, Hefei 230043, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
OFC; Ejector; Waste heat recovery; Energy analysis; Exergy analysis; ENERGY-STORAGE SYSTEM; RANKINE-CYCLE; WORKING FLUID; POWER PRODUCTION; KALINA CYCLE; PERFORMANCE; DESIGN; DRIVEN; OPTIMIZATION; EXPANDER;
D O I
10.1016/j.enconman.2019.02.016
中图分类号
O414.1 [热力学];
学科分类号
摘要
Systems based on Organic Flash Cycle (OFC) are promising technologies for waste heat recovery application due to a better match of the hot and cold heat transfer curves. However, the large amount of exergy lost during the throttling process, results in a low thermal efficiency for OFC. In this work, ejectors are introduced in basic OFC to replace the low pressure throttle valve, high pressure throttle valve and both two throttle valves, which namely Single Ejector and Single Flash evaporator based OFC (SESF-OFC), Single Ejector and Double Flash evaporators based OFC (SEDF-OFC) and Double Ejectors and Double Flash evaporators based OFC (DEDF-OFC), respectively. The thermodynamic analysis including energy analysis, exergy analysis, the parametric analysis and comparison analysis are evaluated by using steady-state mathematical model and thermodynamic laws. The ejector allows a high pressure fluid to entrain and compress a low pressure fluid to a medium pressure. Hence, the mass flow rate or expansion ratio of turbine can be enhanced, results in all of three ejector based OFCs are more efficient than the basic OFC. When the high temperature fluid with temperature of 453.15 K is set as heat source, the maximum global second law efficiency (eta(II,G)) of 38.95% belongs to DEDF-OFC followed SEDF-OFC (37.92%), SESF-OFC (33.68%) and basic OFC (31.43%). The SEDF-OFC is more efficient than SESF-OFC, which indicates that the high pressure throttle valve replaced by ejector is a more effective method than the low pressure throttle valve done. Moreover, the four OFCs have been compared with conventional Organic Rankine Cycle (ORC), and the comparison results show that the eta(II,G) of basic OFC and SESF-OFC are lower than that of ORC, while SEDF-OFC and DEDF-OFC are more efficient than ORC, and the average increment of SEDF-OFC and DEDF-OFC are 10.37% and 15.01%, respectively. Hence, the ejector based OFCs are alternative methods for waste heat recovery application with a high efficiency.
引用
收藏
页码:384 / 395
页数:12
相关论文
共 50 条
  • [41] Thermodynamic analysis of a low-temperature waste heat recovery system based on the concept of solar chimney
    Chen, Kai
    Wang, Jiangfeng
    Dai, Yiping
    Liu, Yuqi
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2014, 80 : 78 - 86
  • [42] Thermodynamic Analysis on the Combined Supercritical CO2/Organic Flash Cycle for Waste Heat Recovery from Shipborne Gas Turbine
    Wang, Xijun
    Wang, Shunsen
    Wu, Chuang
    Liu, Yuting
    Sun, Xingye
    Chen, Da
    [J]. Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2019, 53 (11): : 71 - 78
  • [43] Volumetric expanders for low grade heat and waste heat recovery applications
    Imran, Muhammad
    Usman, Muhammad
    Park, Byung-Sik
    Lee, Dong-Hyun
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2016, 57 : 1090 - 1109
  • [44] Thermodynamic analysis of the combined organic flash and ejector refrigeration cycle using zeotropic mixtures
    Zhao, Dongpeng
    Xu, Weicong
    Zhao, Ruikai
    Deng, Shuai
    Zhao, Li
    [J]. APPLIED THERMAL ENGINEERING, 2023, 219 (0B)
  • [45] Thermodynamic analysis of an organic Rankine cycle for waste heat recovery from gas turbines
    Carcasci, Carlo
    Ferraro, Riccardo
    Miliotti, Edoardo
    [J]. ENERGY, 2014, 65 : 91 - 100
  • [46] Exergy analysis of industrial waste heat recovery based ejector vapour compression refrigeration system
    Kumar, R.
    Khaliq, A.
    [J]. JOURNAL OF THE ENERGY INSTITUTE, 2011, 84 (04) : 192 - 199
  • [47] Thermodynamic and thermo-economic analysis, performance comparison and parameter optimization of basic and regenerative organic Rankine cycles for waste heat recovery
    Feng, Junsheng
    Cheng, Xinni
    Yan, Yaru
    Zhao, Liang
    Dong, Hui
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2023, 52
  • [48] Low grade thermal recovery based on trilateral flash cycles using recent pure fluids and mixtures
    Cipollone, Roberto
    Bianchi, Giuseppe
    Di Bartolomeo, Marco
    Di Battista, Davide
    Fatigati, Fabio
    [J]. PROCEEDINGS OF 1ST INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND RESOURCE USE IN FOOD CHAINS (ICFES 2017), INCLUDING SYMPOSIUM ON HEAT RECOVERY AND EFFICIENT CONVERSION AND UTILISATION OF WASTE HEAT, 2017, 123 : 289 - 296
  • [49] Considerations on alternative organic Rankine Cycle congurations for low-grade waste heat recovery
    Woodland, Brandon J.
    Ziviani, Davide
    Braun, James E.
    Groll, Eckhard A.
    [J]. ENERGY, 2020, 193 : 1134 - 1150
  • [50] Thermodynamic analysis of a combined supercritical CO2 and ejector expansion refrigeration cycle for engine waste heat recovery
    Pan, Mingzhang
    Bian, Xingyan
    Zhu, Yan
    Liang, Youcai
    Lu, Fulu
    Xiao, Gang