Development of the prism-coupler model for the design of a biosensor based on SPR technology for fast diagnostics

被引:1
|
作者
Mazzeo, A. [1 ]
Canal, G. P. [2 ]
Alayo, M. I. [1 ]
机构
[1] Univ Sao Paulo, Polytechn Sch, Sao Paulo, SP, Brazil
[2] Univ Sao Paulo, Inst Phys, Sao Paulo, Brazil
关键词
biosensor; SPR; metallic film; prism-coupler;
D O I
10.1109/SBMICRO55822.2022.9881033
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Biosensors are considered the tools of the future in medicine. With the pandemic caused by the new corona-virus (SARS-COV-2), the development of biosensors with fast diagnostics has become a public health need. Optical biosensors, in particular, have gained strength in the market due to their high sensitivity and detection capability. In this category, sensors based on surface plasmon resonance technology have gained prominence. In this work, a prism-coupler set using the Ktreschamnn configuration was designed and built. The prism-coupler smodel consists of an automated optical-mechanical system and a triangular prism. Thin films of 50 nm of gold and 5 nm of titanium were deposited on glass slices and coupled to a commercial prism (refractive index 1.50). The movement of the optical-mechanical system and the data acquisition are carried out by 2 microcontrollers that are configured using a Labview software. A simulation program using MatLab software was also developed in this work to determine the SPR curves at different refractive index solutions. At first, measurement in air was carried out obtaining a resonance angle in 35 degrees. Afterwards, sucrose solutions were measured using our system at concentrations of 10, 20, 30, 40 and 50%. Finally, experimental and simulated results were compared and analyzed in this work.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Design considerations for development of a magnetic bead based biosensor
    Electronic Engineering Department, Chung Yuan Christian University, Zhong Li, Taiwan
    不详
    不详
    不详
    不详
    Sensors Transducers, 2013, 2 (94-101):
  • [22] Development of a Technique of Fast Timing Analysis for the Design of Standard Cells Based on finfet Technology
    Korshunov, Andrey
    Khvatov, Vasiliy
    Maksimov, Dmitry
    Frolov, Dmitry
    PROCEEDINGS OF THE 2018 IEEE CONFERENCE OF RUSSIAN YOUNG RESEARCHERS IN ELECTRICAL AND ELECTRONIC ENGINEERING (EICONRUS), 2018, : 1383 - 1386
  • [23] Design and analysis of birefringent SPR based PCF biosensor with ultra-high sensitivity and low loss
    Islam, Mohammad Rakibul
    Abu Jamil, Md
    Zaman, Md Siraz-Uz
    Ahsan, Syed Asir Hamim
    Pulak, Mahfuz Kabir
    Mehjabin, Fariha
    Khan, Md Moinul Islam
    Chowdhury, Jubair Alam
    Islam, Mohibul
    OPTIK, 2020, 221
  • [24] Design and analysis of birefringent SPR based PCF biosensor with ultra-high sensitivity and low loss
    Islam, Mohammad Rakibul
    Jamil, Md. Abu
    Zaman, Md. Siraz-Uz
    Ahsan, Syed Asir Hamim
    Pulak, Mahfuz Kabir
    Mehjabin, Fariha
    Khan, Md Moinul Islam
    Chowdhury, Jubair Alam
    Islam, Mohibul
    Optik, 2020, 221
  • [25] Development of DNA biosensor for detection of 3-nitrobenzanthrone (3-NBA) and its metabolites by SPR and QCM technology
    不详
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2005, 34 (06): : 772 - 772
  • [26] Design & Analysis of D-Shaped SPR-Based PCF Biosensor for Detecting Glucose in Urine
    Chakrabortty, Ahan
    Islam, Md. Muhsiul
    Sarker, Md. Abdullah
    Nayan, Md. Faysal
    PLASMONICS, 2025,
  • [27] On the Design of a New 4x4 Coupler for C Band based on a 180° Coupler at Microstrip Technology
    Haro-Baez, Raul
    Benitez, Diego S.
    Romero, David
    2019 IEEE COLOMBIAN CONFERENCE ON COMMUNICATIONS AND COMPUTING (COLCOM 2019), 2019,
  • [28] Performance Evaluation of Prism-Based SPR Biosensor for Detection of Colorectal Cancer Under Radiation Damping: Seeking High Figure-of-Merit
    Singh, Kajal
    Mishra, Adarsh Chandra
    Shukla, Sudhir
    Lohia, Pooja
    Dwivedi, D. K.
    Eldesoky, Gaber E.
    Hossain, M. Khalid
    PLASMONICS, 2025,
  • [29] Bridging basic science and applied diagnostics: Comprehensive viral diagnostics enabled by graphene-based electronic biosensor technology advancements
    Herdina, Anna Nele
    Bozdogan, Anil
    Aspermair, Patrik
    Dostalek, Jakub
    Klausberger, Miriam
    Lingg, Nico
    Cserjan-Puschmann, Monika
    Aguilar, Patricia Pereira
    Auer, Simone
    Demirtas, Halil
    Andersson, Jakob
    Loetsch, Felix
    Holzer, Barbara
    Steinrigl, Adi
    Thalhammer, Florian
    Schellnegger, Julia
    Breuer, Monika
    Knoll, Wolfgang
    Strassl, Robert
    BIOSENSORS & BIOELECTRONICS, 2025, 267
  • [30] Design and analysis of a highly sensitive SPR based PCF biosensor with double step dual peak shift sensitivity
    Islam, Mohammad Rakibul
    Khan, Md Moinul Islam
    Yeasir, Ahmad Jarif
    Mehjabin, Fariha
    Mim, Jannat Ara
    Chowdhury, Jubair Alam
    Nahid, Tajuddin Ahmed
    Islam, Mohibul
    HELIYON, 2023, 9 (08)