Minimally invasive cortical bone trajectory screws placement via pedicle or pedicle rib unit in the lower thoracic spine: a cadaveric and radiographic study

被引:8
|
作者
Xuan, Jun [1 ]
Zhang, Di [1 ]
Jin, Hai-Ming [1 ]
Chen, Jiao-Xiang [1 ]
Xu, Dao-Liang [1 ]
Xu, Hong-Ming [2 ]
Wu, Yao-Sen [1 ]
Wang, Xiang-Yang [1 ]
机构
[1] Wenzhou Med Univ, Affiliated Hosp 2, Dept Orthopaed Surg, 109 Xueyuanxi Rd, Wenzhou 325027, Peoples R China
[2] Wenzhou Med Univ, Affiliated Cixi Hosp, Dept Orthopaed Surg, Ningbo 315300, Peoples R China
关键词
Minimally invasive; Cortical bone trajectory screws; Thoracic pedicle screws; Rescue failed screws; Pedicle rib unit; MORPHOMETRIC MEASUREMENT; TRANSPEDICULAR SCREWS; IDIOPATHIC SCOLIOSIS; MORPHOLOGY; FIXATION; CT;
D O I
10.1007/s00586-016-4730-y
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To evaluate the feasibility of cortical bone trajectory (CBT) screws fixation via pedicle or pedicle rib unit in the cadaveric thoracic spine (T9-T12). Computed tomography (CT) images of 100 patients are analyzed by multiplanar reconstruction. Ten cadaveric thoracic spines are used to insert 4.5 x 35.0 mm CBT screws at all levels from T9 to T12. Maximal screw length obtained by CT has a tendency to gradually increase from T9 (29.64 mm) to T12 (32.84 mm), and the difference reaches significant level at all levels except T9 versus T10 (P < 0.01). Maximal screw diameter increases from T9 (4.92 mm) to T12 (7.47 mm) and the difference reaches significant level among all levels (P < 0.01). Lateral angle increases from T9 (7.37A degrees) to T12 (10.47A degrees), and the difference reaches significant level among all levels except T11 versus T12. Cephalad angle from T9 to T12 are 19.03A degrees, 22.10A degrees, 25.62A degrees and 27.50A degrees (P < 0.01), respectively. The percentage of the inner and outer pedicle breakage are 2.5 and 22.5 %, respectively. The violation of lateral pedicle wall occurs at T9 and T10, especially for women at T9. Both radiographic and cadaveric studies establish the feasibility of CBT screws placement via pedicle or pedicle rib unit in the lower thoracic spine (T9-T12). Furthermore, our measurements are also useful for application of this technique.
引用
收藏
页码:4199 / 4207
页数:9
相关论文
共 50 条
  • [1] Minimally invasive cortical bone trajectory screws placement via pedicle or pedicle rib unit in the lower thoracic spine: a cadaveric and radiographic study
    Jun Xuan
    Di Zhang
    Hai-Ming Jin
    Jiao-Xiang Chen
    Dao-Liang Xu
    Hong-Ming Xu
    Yao-Sen Wu
    Xiang-Yang Wang
    European Spine Journal, 2016, 25 : 4199 - 4207
  • [2] Pedicle instrumentation in the thoracic spine - A morphometric and cadaveric study for placement of screws
    Cinotti, G
    Gumina, S
    Ripani, M
    Postacchini, F
    SPINE, 1999, 24 (02) : 114 - 119
  • [3] Cortical bone trajectory screws placement via pedicle or pedicle rib unit in the pediatric thoracic spine (T9-T12) A 2-dimensional multiplanar reconstruction study using computed tomography
    Xuan, Jun
    Chen, Jian
    He, Hui
    Jin, Hai-Ming
    Zhang, Di
    Wu, Yao-Sen
    Tian, Nai-Feng
    Wang, Xiang-Yang
    MEDICINE, 2017, 96 (05)
  • [4] Novel Placement of Cortical Bone Trajectory Screws in the Lumbar Spine A Radiographic and Cadaveric Study
    Gao, Hai
    Zhang, Renjie
    Jia, Chongyu
    Xing, Tao
    Zhang, Jianxiang
    Dong, Fulong
    Ge, Peng
    Song, Peiwen
    Xu, Peng
    Zhang, Huaqing
    Li, Huimin
    Shen, Cailiang
    CLINICAL SPINE SURGERY, 2018, 31 (06): : E329 - E336
  • [5] Minimally invasive PLIF with divergent, cortical trajectory pedicle screws
    Pedro Berjano
    Marco Damilano
    Maryem Ismael
    Carlo Formica
    Diego Garbosa
    European Spine Journal, 2015, 24 : 654 - 655
  • [6] Minimally invasive PLIF with divergent, cortical trajectory pedicle screws
    Berjano, Pedro
    Damilano, Marco
    Ismael, Maryem
    Formica, Carlo
    Garbosa, Diego
    EUROPEAN SPINE JOURNAL, 2015, 24 : S654 - S655
  • [7] Cortical Bone Trajectory for Thoracic Pedicle Screws A Technical Note
    Matsukawa, Keitaro
    Yato, Yoshiyuki
    Hynes, Richard A.
    Imabayashi, Hideaki
    Hosogane, Naobumi
    Asazuma, Takashi
    Matsui, Toshiyasu
    Kobayashi, Yasushi
    Nemoto, Koichi
    CLINICAL SPINE SURGERY, 2017, 30 (05): : E497 - E504
  • [8] Erratum to: Minimally invasive PLIF with divergent, cortical trajectory pedicle screws
    Pedro Berjano
    Marco Damilano
    Maryem Ismael
    Carlo Formica
    Diego Garbossa
    European Spine Journal, 2015, 24 : 2096 - 2096
  • [9] PLACEMENT OF PEDICLE SCREWS IN THE THORACIC SPINE .2. AN ANATOMICAL AND RADIOGRAPHIC ASSESSMENT
    VACCARO, AR
    RIZZOLO, SJ
    BALDERSTON, RA
    ALLARDYCE, TJ
    GARFIN, SR
    DOLINSKAS, C
    AN, HS
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77A (08): : 1200 - 1206
  • [10] Pullout strength of thoracic pedicle screws improved with cortical bone ratio: a cadaveric study
    Chou, Wen-Kai
    Chien, Andy
    Wang, Jaw-Lin
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2014, 19 (06) : 900 - 906