Effect of UPFC on protection of transmission lines with infeed current

被引:14
|
作者
Pazoki, Mohammad [1 ]
Moravej, Zahra [1 ]
Khederzadeh, Mojtaba [2 ]
Nair, Nirmal-Kumar C. [3 ]
机构
[1] Semnan Univ, Elect & Comp Engn Fac, Semnan, Iran
[2] Shahid Beheshti Univ, Elect & Comp Engn Dept, Tehran, AC, Iran
[3] Univ Auckland, Dept Elect & Comp Engn, Auckland, New Zealand
关键词
distance protection; infeed current; UPFC; real-time simulation; REAL-TIME IMPLEMENTATION; DISTANCE PROTECTION; PERFORMANCE; RELAY; SHUNT; SYSTEMS; SSSC;
D O I
10.1002/etep.2212
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The increasing penetration of flexible AC transmission system devices and renewable generation resources within existing conventional power system networks has necessitated the relook into protective relaying schemes for ensuring grid security and integrity. This paper investigates the impact of a unified power flow controller (UPFC) on Zones 1 and 2 (with infeed current) of the conventional distance relay and pilot protection schemes. Using both analytical and detailed simulation techniques, these schemes have been very thoroughly assessed. The protection impacts for four functions of UPFC are compared with each other comprehensively. The infeed current effect for existing distance relay, as represented by standard MHO characteristics, has been adapted to factor the effect of source and line impedances. In addition, a proposed modification procedure highlights the main reasons for the impedance trajectory changes during faults at Zones 1 and 2 resulting due to the presence of the UPFC. A detailed model of UPFC and six measuring units of distance protection have been developed in the MATLAB/Simulink environment. The accuracy of compensated network and impedance measuring units are verified using Opal-RT's RT-LAB real-time engineering emulator. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:2385 / 2401
页数:17
相关论文
共 50 条
  • [1] Three-Terminal Transmission Line Protection By Considering Effect of Infeed Current
    Desai J.P.
    Journal of The Institution of Engineers (India): Series B, 2022, 103 (06) : 2165 - 2175
  • [2] Analysis by Traveling Waves for a Protection Scheme of Transmission Lines with a UPFC
    Rodriguez-Herrejon, Javier
    Reyes-Archundia, Enrique
    Gutierrez-Gnecchi, Jose A.
    Olivares-Rojas, Juan
    Mendez-Patino, Arturo
    IEEE LATIN AMERICA TRANSACTIONS, 2024, 22 (01) : 46 - 54
  • [3] SUPERIMPOSED MOVING SUM Approach for Protection of Transmission Lines Possessing UPFC
    Kumar, Prakash
    Kumar, Shubhankar
    Kumar, Ravi
    2018 INTERNATIONAL CONFERENCE ON COMPUTING, POWER AND COMMUNICATION TECHNOLOGIES (GUCON), 2018, : 1107 - 1110
  • [4] Adaptive ground distance protection for UPFC compensated transmission lines: A formulation considering the fault resistance effect
    Rodriguez Paz, Martin Cruz
    Leborgne, Roberto Chouhy
    Bretas, Arturo Suman
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2015, 73 : 124 - 131
  • [5] Fault analysis and main protection scheme of parallel lines transmission system considering weak-infeed effect
    Zeng, Geng-Hui
    Cai, Ze-Xiang
    Li, Yi-Quan
    Cao, Jian-Dong
    Chen, Qiao-Ping
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2011, 39 (18): : 62 - 66
  • [6] Superimposed Component-Based Protection Scheme for UPFC Compensated Transmission Lines
    Biswas, Sauvik
    Nayak, Paresh Kumar
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [7] Improvement of Distance Protection with SVM on PV-Fed Transmission Lines in Infeed Conditions
    Yoldas, Yasar Beyazit
    Yumurtaci, Recep
    ENERGIES, 2023, 16 (06)
  • [8] CURRENT PROTECTION DEVICES FOR TRANSMISSION LINES.
    Nudel'man, G.S.
    Malyi, A.P.
    Shamis, M.A.
    Soviet electrical engineering, 1985, 56 (03): : 25 - 29
  • [9] A New Cross-Differential Protection Scheme for Parallel Transmission Lines Including UPFC
    Samantaray, Subhransur
    Tripathy, Lokanath
    Dash, Pradipta
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [10] A New Cross-Differential Protection Scheme for Parallel Transmission Lines Including UPFC
    Tripathy, L. N.
    Dash, P. K.
    Samantaray, S. R.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (04) : 1822 - 1830