Optimization of a flow injection system with amperometric detection for arsenic determination

被引:12
|
作者
Lolic, Aleksandar [1 ]
Nikolic, Snezana [1 ]
Mutic, Jelena [1 ]
机构
[1] Univ Belgrade, Fac Chem, Belgrade 11000, Serbia
关键词
D O I
10.2116/analsci.24.877
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A selective and sensitive analytical procedure for rapid arsenic determination by gas-diffusion flow injection analysis with amperometric detection was developed. The method is based on the arsenite reduction by NaBH4. Derived arsine diffuses through a PTF membrane into the acceptor flow stream and is amperometrically determined on a platinum working electrode. The limit of detection (3 a) at room temperature was 5 gg/dm(3) of As(III). The relative standard deviation for a 1 mg/dm(3) As(III) standard was 1.96% for six repetitive injections. Arsenic(V) was determined after its prereduction with potassium iodide. Arsenic determination was not interferred with by 1 mg/dm(3) Sb(III), 5 mg/dm(3) Sn(II), 10 mg/dm(3) Se(IV), 1 mg/dm(3) As(V), 1 mg/dm(3) hydrasine, 1 mg/dm(3) Fe(II) or 0.5 mg/dm(3) Fe(III) solution. The throughput of this method was 60 analyses per hour. This method was successfully applied to arsenic determination in some power plant waste water samples.
引用
收藏
页码:877 / 880
页数:4
相关论文
共 50 条
  • [1] Optimization of a Flow Injection System with Amperometric Detection for Arsenic Determination
    Aleksandar Lolic
    Snezana Nikolic
    Jelena Mutic
    Analytical Sciences, 2008, 24 : 877 - 880
  • [2] Determination of arsenic in industrial samples by pervaporation flow injection with amperometric detection
    Rupasinghe, Thusitha W. T.
    Cardwell, Terence J.
    Cattrall, Robert W.
    Kolev, Spas D.
    ANALYTICA CHIMICA ACTA, 2009, 652 (1-2) : 266 - 271
  • [3] INDIRECT DETERMINATION OF IRON IN A FLOW-INJECTION SYSTEM WITH AMPEROMETRIC DETECTION
    SILVA, L
    LEON, LE
    CALVO, A
    ANALYTICA CHIMICA ACTA, 1987, 192 (02) : 349 - 353
  • [4] Flow Injection System with Amperometric Detection for Determination of Iodine Value of Vegetable Oils
    Kruatian, Thidarat
    Jitmanee, Kritsana
    Jakmunee, Jaroon
    CHIANG MAI JOURNAL OF SCIENCE, 2021, 48 (02): : 557 - 567
  • [5] A flow-injection system with amperometric detection for selective determination of antioxidants in foodstuffs and drinks
    Yashin, A. Ya.
    RUSSIAN JOURNAL OF GENERAL CHEMISTRY, 2008, 78 (12) : 2566 - 2571
  • [6] An automatic determination of caffeine in soft drinks using flow injection system with amperometric detection
    Lima, JLFC
    Delerue-Matos, C
    Nouws, HPA
    Vaz, MCVF
    FOOD ADDITIVES AND CONTAMINANTS, 1998, 15 (03): : 265 - 269
  • [7] Determination of chlorine ions in raw milk by pulsed amperometric detection in a flow injection system
    Chen, Xingguang
    Chu, Beibei
    Xi, Huiting
    Xu, Junjun
    Lai, Lizhi
    Peng, Huifeng
    Deng, Danwen
    Huang, Ganhui
    JOURNAL OF DAIRY SCIENCE, 2018, 101 (11) : 9647 - 9658
  • [8] A flow-injection system with amperometric detection for selective determination of antioxidants in foodstuffs and drinks
    A. Ya. Yashin
    Russian Journal of General Chemistry, 2008, 78
  • [9] Flow injection determination of sialic acid based on amperometric detection
    Marzouk, Sayed A. M.
    Haddow, Jody D.
    Amin, Amr
    SENSORS AND ACTUATORS B-CHEMICAL, 2011, 157 (02) : 647 - 653
  • [10] Determination of esterase activity by flow injection analysis with amperometric detection
    Takamura, K