Label-free high-throughput imaging flow cytometry

被引:3
|
作者
Mahjoubfar, A. [1 ,2 ]
Chen, C. [1 ,2 ]
Niazi, K. R. [2 ,3 ,4 ]
Rabizadeh, S. [2 ,3 ,4 ]
Jalali, B. [1 ,2 ,3 ,5 ]
机构
[1] Univ Calif Los Angeles, Dept Elect Engn, Los Angeles, CA 90095 USA
[2] California NanoSystems Inst, Los Angeles, CA USA
[3] Univ Calif Los Angeles, Dept Bioengn, Los Angeles, CA USA
[4] NantWorks LLC, Culver City, CA USA
[5] Univ Calif Los Angeles, David Geffen Sch Med, Dept Surg, Los Angeles, CA 90095 USA
关键词
Ultrafast imaging; Serial time-encoded amplified microscopy (STEAM); Phase contrast microscopy; Flow cytometry; Cell analysis; Medical optics; Label-free; Protein concentration; DENSITY-GRADIENT CENTRIFUGATION; REFRACTIVE-INDEX; TUMOR-CELLS; LIVING CELLS; MICROSCOPY; SEPARATION; VOLUME;
D O I
10.1117/12.2040881
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Flow cytometry is an optical method for studying cells based on their individual physical and chemical characteristics. It is widely used in clinical diagnosis, medical research, and biotechnology for analysis of blood cells and other cells in suspension. Conventional flow cytometers aim a laser beam at a stream of cells and measure the elastic scattering of light at forward and side angles. They also perform single-point measurements of fluorescent emissions from labeled cells. However, many reagents used in cell labeling reduce cellular viability or change the behavior of the target cells through the activation of undesired cellular processes or inhibition of normal cellular activity. Therefore, labeled cells are not completely representative of their unaltered form nor are they fully reliable for downstream studies. To remove the requirement of cell labeling in flow cytometry, while still meeting the classification sensitivity and specificity goals, measurement of additional biophysical parameters is essential. Here, we introduce an interferometric imaging flow cytometer based on the world's fastest continuous-time camera. Our system simultaneously measures cellular size, scattering, and protein concentration as supplementary biophysical parameters for label-free cell classification. It exploits the wide bandwidth of ultrafast laser pulses to perform blur-free quantitative phase and intensity imaging at flow speeds as high as 10 meters per second and achieves nanometer-scale optical path length resolution for precise measurements of cellular protein concentration.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] High-Throughput Metabolite Analysis of Unicellular Microalgae by Orthogonal Hybrid Ionization Label-Free Mass Cytometry
    Yao, Huan
    Yang, Jinlei
    Wang, Zhengmao
    Pan, Xingyu
    Pan, Junmin
    Li, Hongmei
    Zhang, Sichun
    ANALYTICAL CHEMISTRY, 2024, 96 (28) : 11404 - 11411
  • [32] High-throughput label-free image cytometry and image-based classification of live Euglena gracilis
    Lei, Cheng
    Ito, Takuro
    Ugawa, Masashi
    Nozawa, Taisuke
    Iwata, Osamu
    Maki, Masanori
    Okada, Genki
    Kobayashi, Hirofumi
    Sun, Xinlei
    Tiamsak, Pimsiri
    Tsumura, Norimichi
    Suzuki, Kengo
    Di Carlo, Dino
    Ozeki, Yasuyuki
    Goda, Keisuke
    BIOMEDICAL OPTICS EXPRESS, 2016, 7 (07): : 2703 - 2708
  • [33] Label-Free High-Throughput Leukemia Detection by Holographic Microscopy
    Ugele, Matthias
    Weniger, Markus
    Stanzel, Manfred
    Bassler, Michael
    Krause, Stefan W.
    Friedrich, Oliver
    Hayden, Oliver
    Richter, Lukas
    ADVANCED SCIENCE, 2018, 5 (12)
  • [34] Label-free, high-throughput, electrical detection of cells in droplets
    Kemna, Evelien W. M.
    Segerink, Loes I.
    Wolbers, Floor
    Vermes, Istvan
    van den Berg, Albert
    ANALYST, 2013, 138 (16) : 4585 - 4592
  • [35] High-Throughput Flow Cytometry
    Robinson, J. Paul
    Patsekin, Valery
    Rajwa, Bartek
    Davisson, V. Jo
    Li, Nianyu
    Narayanan, Padmakumar
    GENETIC ENGINEERING & BIOTECHNOLOGY NEWS, 2011, 31 (08): : 20 - +
  • [36] Use of Microarrays as a High-Throughput Platform for Label-Free Biosensing
    Sun, Yung-Shin
    JALA, 2015, 20 (04): : 334 - 353
  • [37] An Automated Pipeline for High-Throughput Label-Free Quantitative Proteomics
    Weisser, Hendrik
    Nahnsen, Sven
    Grossmann, Jonas
    Nilse, Lars
    Quandt, Andreas
    Brauer, Hendrik
    Sturm, Marc
    Kenar, Erhan
    Kohlbacher, Oliver
    Aebersold, Ruedi
    Malinstroemt, Lars
    JOURNAL OF PROTEOME RESEARCH, 2013, 12 (04) : 1628 - 1644
  • [38] High-Throughput, Label-Free and Slide-Free Histological Imaging by Computational Microscopy and Unsupervised Learning
    Zhang, Yan
    Kang, Lei
    Wong, Ivy H. M.
    Dai, Weixing
    Li, Xiufeng
    Chan, Ronald C. K.
    Hsin, Michael K. Y.
    Wong, Terence T. W.
    ADVANCED SCIENCE, 2022, 9 (02)
  • [39] Label-free sperm morphology assessment using imaging flow cytometry
    Vaidyanathan, S.
    Li, A.
    Didion, B. A.
    Friend, S.
    Morrissey, P.
    REPRODUCTION IN DOMESTIC ANIMALS, 2015, 50 : 128 - 128
  • [40] Label-free high-throughput photoacoustic imaging of circulating melanoma tumor cells in patients in vivo
    Hai, P.
    Shmuylovich, L.
    Qu, Y.
    Cornelius, L. A.
    Wang, L.
    JOURNAL OF INVESTIGATIVE DERMATOLOGY, 2018, 138 (05) : S204 - S204