Measurement of Tear Film Thickness Using Ultrahigh-Resolution Optical Coherence Tomography

被引:111
|
作者
Werkmeister, Rene M. [1 ]
Alex, Aneesh [1 ]
Kaya, Semira [2 ]
Unterhuber, Angelika [1 ]
Hofer, Bernd [1 ]
Riedl, Jasmin [1 ]
Bronhagl, Michael [1 ]
Vietauer, Martin [1 ]
Schmidl, Doreen [2 ]
Schmoll, Tilman [1 ]
Garhoefer, Gerhard [2 ]
Drexler, Wolfgang [1 ]
Leitgeb, Rainer A. [1 ]
Groeschl, Martin [3 ]
Schmetterer, Leopold [1 ,2 ]
机构
[1] Med Univ Vienna, Ctr Med Phys & Biomed Engn, Vienna, Austria
[2] Med Univ Vienna, Dept Clin Pharmacol, Vienna, Austria
[3] Vienna Univ Technol, Inst Appl Phys, A-1040 Vienna, Austria
关键词
optical coherence tomography; tear film thickness; dry eyes; EYE WORKSHOP 2007; INTERNATIONAL WORKSHOP; PRECORNEAL; SUBCOMMITTEE; DISEASE; PRELENS; INDEX;
D O I
10.1167/iovs.13-11920
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To visualize the precorneal tear film with ultrahigh-resolution spectral domain optical coherence tomography, enabling quantification of tear film thickness in healthy subjects. METHODS. A custom-built spectral domain optical coherence tomography system comprising a broadband titanium: sapphire laser operating at 800 nm and a high-speed charge coupled device (CCD) camera with a read-out rate of 47 kHz was used for measurement of precorneal tear film thickness. The system provides a theoretical axial resolution of 1.2 mu m in tissue. The signal-to-noise ratio close to the zero delay was measured with 94 dB. A total of 26 healthy subjects were included in this study. Measurement was started immediately after blinking and averaged over a period of 1 second. In a subset of eight healthy subjects, the reproducibility of the approach was studied by measuring the tear film thickness every 10 minutes over 1 hour. RESULTS. The average central tear film thickness of the measured population was 4.79 +/- 0.88 mu m. Reproducibility was very high, with an intraclass correlation coefficient of 0.97. A breakup of the tear film was observed in one subject after 14 seconds. CONCLUSIONS. Our data indicate that the human precorneal tear film can be measured with excellent reproducibility using ultrahigh-resolution optical coherence tomography. This technique may be a valuable tool in the management of dry eye syndrome. (ClinicalTrials.gov number, NCT01746602.)
引用
收藏
页码:5578 / 5583
页数:6
相关论文
共 50 条
  • [31] Findings of secondary corneal amyloidosis with ultrahigh-resolution optical coherence tomography
    Araki-Sasaki, Kaoru
    Osakabe, Yasuhiro
    Fukuoka, Hideki
    Ideta, Ryuichi
    Hirano, Koji
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 2115 - 2119
  • [32] Quantitative Evaluation of Caries and Calculus with Ultrahigh-Resolution Optical Coherence Tomography
    Wang, Tai-Ang
    Trung, Nguyen Hoang
    Lee, Hsiang-Chieh
    Lee, Cheng-Kuang
    Tsai, Meng-Tsan
    Wang, Yen-Li
    [J]. BIOENGINEERING-BASEL, 2023, 10 (11):
  • [33] Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction
    Zawadzki, Robert J.
    Cense, Barry
    Zhang, Yan
    Choi, Stacey S.
    Miller, Donald T.
    Werner, John S.
    [J]. OPTICS EXPRESS, 2008, 16 (11) : 8126 - 8143
  • [34] Ultrahigh-resolution optical coherence tomography of surgically closed macular holes
    Ko, Tony H.
    Witkin, Andre J.
    Fujimoto, James G.
    Chan, Annie
    Rogers, Adam H.
    Baumal, Caroline R.
    Schuman, Joel S.
    Drexler, Wolfgang
    Reichel, Elias
    Duker, Jay S.
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2006, 124 (06) : 827 - 836
  • [35] Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
    Herz, PR
    Chen, Y
    Aguirre, AD
    Schneider, K
    Hsiung, P
    Fujimoto, JG
    Madden, K
    Schmitt, J
    Goodnow, J
    Petersen, C
    [J]. OPTICS LETTERS, 2004, 29 (19) : 2261 - 2263
  • [36] Stroboscopic ultrahigh-resolution full-field optical coherence tomography
    Moneron, G
    Boccara, AC
    Dubois, A
    [J]. OPTICS LETTERS, 2005, 30 (11) : 1351 - 1353
  • [37] Photoreceptor Layer Thickness Changes During Dark Adaptation Observed With Ultrahigh-Resolution Optical Coherence Tomography
    Lu, Chen D.
    Lee, ByungKun
    Schottenhamml, Julia
    Maier, Andreas
    Pugh, Edward N., Jr.
    Fujimoto, James G.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (11) : 4632 - 4643
  • [38] The effect of water dispersion and absorption on axial resolution in ultrahigh-resolution optical coherence tomography
    Hillman, TR
    Sampson, DD
    [J]. OPTICS EXPRESS, 2005, 13 (06): : 1860 - 1874
  • [39] Quantification of photoreceptor layer thickness using ultrahigh resolution optical coherence tomography
    Hermann, B
    Unterhuber, A
    Wirtitsch, M
    Stur, M
    Ergun, E
    Scholda, C
    Ko, T
    Schuman, JS
    Fujimoto, JG
    Drexler, W
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U927 - U927
  • [40] Imaging of oocyte development using ultrahigh-resolution full-field optical coherence tomography
    Xiao, Jiaying
    Wang, Bo
    Lu, Guangyin
    Zhu, Ziqiang
    Huang, Yujiao