Differentiation of benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional shear-wave elastography

被引:104
|
作者
Lee, Su Hyun [1 ]
Chang, Jung Min [1 ]
Kim, Won Hwa [1 ]
Bae, Min Sun [1 ]
Cho, Nariya [1 ]
Yi, Ann [2 ]
Koo, Hye Ryoung [1 ]
Kim, Seung Ja [2 ]
Kim, Jin You [3 ]
Moon, Woo Kyung [1 ]
机构
[1] Seoul Natl Univ Hosp, Dept Radiol, Seoul 100744, South Korea
[2] Seoul Natl Univ, Seoul Metropolitan Govt, Dept Radiol, Boramae Med Ctr, Seoul, South Korea
[3] Pusan Natl Univ Hosp, Dept Radiol, Pusan, South Korea
关键词
Breast neoplasms; Ultrasound; Elasticity imaging techniques; Shear wave elastography; Imaging; Three-dimensional; TUMOR HETEROGENEITY; US; ULTRASONOGRAPHY;
D O I
10.1007/s00330-012-2686-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To prospectively compare the diagnostic performances of two-dimensional (2D) and three-dimensional (3D) shear-wave elastography (SWE) for differentiating benign from malignant breast masses. B-mode ultrasound and SWE were performed for 134 consecutive women with 144 breast masses before biopsy. Quantitative elasticity values (maximum and mean elasticity in the stiffest portion of mass, E-max and E-mean; lesion-to-fat elasticity ratio, E-rat) were measured with both 2D and 3D SWE. The area under the receiver operating characteristic curve (AUC), sensitivity and specificity of B-mode, 2D, 3D SWE and combined data of B-mode and SWE were compared. Sixty-seven of the 144 breast masses (47 %) were malignant. Overall, higher elasticity values of 3D SWE than 2D SWE were noted for both benign and malignant masses. The AUC for 2D and 3D SWE were not significantly different: E-mean, 0.938 vs 0.928; E-max, 0.939 vs 0.930; E-rat, 0.907 vs 0.871. Either 2D or 3D SWE significantly improved the specificity of B-mode ultrasound from 29.9 % (23 of 77) up to 71.4 % (55 of 77) and 63.6 % (49 of 77) without a significant change in sensitivity. Two-dimensional and 3D SWE performed equally in distinguishing benign from malignant masses and both techniques improved the specificity of B-mode ultrasound. aEuro cent Shear-wave elastography (SWE) is increasingly used during ultrasound of the breast aEuro cent 2D and 3D SWE performed equally in distinguishing benign from malignant masses aEuro cent Either SWE method, combined with B-mode, outperformed B-mode ultrasound alone aEuro cent Quantitative elasticity was greater for 3D than 2D SWE for all masses.
引用
收藏
页码:1015 / 1026
页数:12
相关论文
共 50 条
  • [41] Three-dimensional transient and harmonic shear-wave scattering by a soft cylinder for dynamic vascular elastography
    Laboratory of Biorheology and Medical Ultrasonics, University of Montreal Hospital Research Center, Montreal, QC H2L 2W5, Canada
    不详
    不详
    Journal of the Acoustical Society of America, 2008, 124 (04): : 2394 - 2405
  • [42] Two-dimensional shear wave elastography with two different systems for the diagnosis of breast lesions
    Yu, Ji-Feng
    Zhang, Shen
    Yin, Hao-Hao
    Zhou, Bang-Guo
    Pu, Yin-Ying
    Fang, Yan
    Du, Dou
    Zhang, Yan
    Xu, Hui-Xiong
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2022, 82 (01) : 53 - 62
  • [43] Diagnostic utility of strain and shear wave ultrasound elastography in differentiation of benign and malignant solid breast lesions
    Ahmed Tohamy Ahmed
    Egyptian Journal of Radiology and Nuclear Medicine, 51
  • [44] Diagnostic utility of strain and shear wave ultrasound elastography in differentiation of benign and malignant solid breast lesions
    Ahmed, Ahmed Tohamy
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2020, 51 (01):
  • [45] Role of supersonic shear wave imaging quantitative elastography (SSI) in differentiating benign and malignant solid breast masses
    Awad, Fatma Mohamed
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2013, 44 (03): : 681 - 685
  • [46] Intra-individual comparison of liver stiffness measurements by magnetic resonance elastography and two-dimensional shear-wave elastography in 888 patients
    Ichikawa, Hideo
    Yasuda, Eisuke
    Kumada, Takashi
    Takeshima, Kenji
    Ogawa, Sadanobu
    Tsunekawa, Akikazu
    Goto, Tatsuya
    Nakaya, Koji
    Akita, Tomoyuki
    Tanaka, Junko
    ULTRASONOGRAPHY, 2023, 42 (01) : 65 - 77
  • [47] Two-Dimensional Shear-Wave Elastography of the Thyroid in Clinically Healthy Dogs in Different Age Groups
    Ramos, Denise Jaques
    Disselli, Tamiris
    Gomes, Diego Rodrigues
    Aires, Luiz Paulo Nogueira
    Tinto, Stefany Tagliatela
    Salazar, Diana Villa Verde
    Pereira, Mariane Magno Ferreira
    de Miranda, Brenda Santos Pompeu
    de Oliveira, Ana Paula Luiz
    Lima, Bruna Bressianini
    Uscategui, Ricardo Andres Ramirez
    Feliciano, Marcus Antonio Rossi
    ANIMALS, 2024, 14 (11):
  • [48] Shear wave versus strain elastography in the differentiation of benign and malignant breast lesions
    Guruf, Aykut
    Ozturk, Mesut
    Bayrak, Ilkay Koray
    Polat, Ahmet Veysel
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2019, 49 (05) : 1509 - 1517
  • [49] Two-dimensional Shear-Wave Elastography and Conventional US: The Optimal Evaluation of Liver Fibrosis and Cirrhosis
    Zheng, Jian
    Guo, Huanyi
    Zeng, Jie
    Huang, Zeping
    Zheng, Bowen
    Ren, Jie
    Xu, Erjiao
    Li, Kai
    Zheng, Rongqin
    RADIOLOGY, 2015, 275 (01) : 290 - 300
  • [50] Comparison of point and two-dimensional shear wave elastography of the spleen in healthy subjects
    Nowotny, Friederike
    Schmidberger, Julian
    Schlingeloff, Patrycja
    Binzberger, Andreas
    Kratzer, Wolfgang
    WORLD JOURNAL OF RADIOLOGY, 2021, 13 (05): : 137 - 148