Aptamer-based label-free detection of PDGF using ruthenium(II) complex as luminescent probe

被引:21
|
作者
Babu, E. [1 ]
Singaravadivel, S. [1 ]
Manojkumar, P. [2 ]
Krishnasamy, S. [2 ]
Kumar, G. Gnana [1 ]
Rajagopal, S. [1 ]
机构
[1] Madurai Kamaraj Univ, Sch Chem, Dept Phys Chem, Madurai 625021, Tamil Nadu, India
[2] Madurai Kamaraj Univ, Sch Biotechnol, Dept Genet Engn, Madurai 625021, Tamil Nadu, India
关键词
Ru(II) complex; Aptamer; PDGF; Biosensor; Luminescence; GROWTH-FACTOR; DNA; BINDING;
D O I
10.1007/s00216-013-7118-4
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a simple, cost-effective, and label-free detection method, consisting of a platelet-derived growth factor (PDGF) binding aptamer and hydrophobic Ru(II) complex as a sensor system for PDGF. The binding of PDGF with the aptamer results in the weakening of the aptamer-Ru(II) complex, monitored by luminescence signal. A substantial enhancement in the luminescence intensity of Ru(II) complex is observed in the presence of aptamer due to the hydrophobic interaction. Upon addition of PDGF, the luminescence intensity is decreased, due to the stronger interaction between the aptamer and PDGF resulting in the displacement of Ru(II) complex to the aqueous solution. Our assay can detect a target specifically in a complex medium such as the mixture of proteins, at a concentration of 0.8 pM.
引用
收藏
页码:6891 / 6895
页数:5
相关论文
共 50 条
  • [1] Aptamer-based label-free detection of PDGF using ruthenium(II) complex as luminescent probe
    E. Babu
    S. Singaravadivel
    P. Manojkumar
    S. Krishnasamy
    G. Gnana kumar
    S. Rajagopal
    Analytical and Bioanalytical Chemistry, 2013, 405 : 6891 - 6895
  • [2] Ultrasensitive label-free aptamer-based electronic detection
    Xiang, Yun
    Xie, Mingyi
    Bash, Ralph
    Chen, Julian J. L.
    Wang, Joseph
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2007, 46 (47) : 9054 - 9056
  • [3] Label-free aptamer-based chemiluminescence detection of adenosine
    Yan, Xiluan
    Cao, Zhijuan
    Kai, Masaaki
    Lu, Jianzhong
    TALANTA, 2009, 79 (02) : 383 - 387
  • [4] Detection of Oxytetracycline Using an Electrochemical Label-Free Aptamer-Based Biosensor
    Akbarzadeh, Sanaz
    Khajehsharifi, Habibollah
    Hajihosseini, Saeedeh
    BIOSENSORS-BASEL, 2022, 12 (07):
  • [5] Aptamer-based label-free direct detection of thrombin using SERS
    Pagba, Cynthia V.
    Cho, Hansang
    Lane, Stephen
    Wachsmann-Hogiu, Sebastian
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2009, 237 : 491 - 491
  • [6] Label-Free Aptamer-Based Biosensor for Specific Detection of Chloramphenicol Using AIE Probe and Graphene Oxide
    Zhang, Song
    Ma, Lian
    Ma, Ke
    Xu, Bin
    Liu, Leijing
    Tian, Wenjing
    ACS OMEGA, 2018, 3 (10): : 12886 - 12892
  • [7] Aptamer-based biosensors for label-free voltammetric detection of lysozyme
    Cheng, Alan K. H.
    Ge, Bixia
    Yu, Hua-Zhong
    ANALYTICAL CHEMISTRY, 2007, 79 (14) : 5158 - 5164
  • [8] Aptamer-Based Microcantilever Biosensors for Label-Free PSA Detection
    Gao, Fei
    Qi Li, Zhao
    Li, Jiao Yang
    Li, Zhe Yi
    Wei, Jie
    Ding, Xumin
    Wang, Lei
    Zhai, Lei Ying
    Nan, Jing Chang
    Wang, Cong
    IEEE SENSORS JOURNAL, 2025, 25 (01) : 266 - 273
  • [9] Aptamer-Based Label-Free Impedimetric Biosensor for Detection of Progesterone
    Jimenez, Gaston Contreras
    Eissa, Shimaa
    Ng, Andy
    Alhadrami, Hani
    Zourob, Mohammed
    Siaj, Mohamed
    ANALYTICAL CHEMISTRY, 2015, 87 (02) : 1075 - 1082
  • [10] A Label-Free Aptamer-Based Fluorescent Assay for Cadmium Detection
    Luan, Yunxia
    Lu, Anxiang
    Chen, Jiayi
    Fu, Hailong
    Xu, Li
    APPLIED SCIENCES-BASEL, 2016, 6 (12):