Hyperbaric vs. isobaric bupivacaine for spinal anaesthesia for elective caesarean section: a Cochrane systematic review

被引:23
|
作者
Sng, B. L. [1 ]
Han, N. L. R. [2 ]
Leong, W. L. [1 ]
Sultana, R. [4 ]
Siddiqui, F. J. [5 ]
Assam, P. N. [6 ]
Chan, E. S. [6 ]
Tan, K. H. [3 ]
Sia, A. T. [1 ]
机构
[1] KK Womens & Childrens Hosp, Womens Anaesthesia, Singapore, Singapore
[2] KK Womens & Childrens Hosp, Div Clin Support Serv, Singapore, Singapore
[3] KK Womens & Childrens Hosp, Obstet & Gynaecol, Singapore, Singapore
[4] Duke NUS Grad Med Sch, Ctr Quantitat Med, Singapore, Singapore
[5] Sick Kids Hosp, Ctr Global Child Hlth, Toronto, ON, Canada
[6] Clin Res Inst, Singapore, Singapore
关键词
bupivacaine; hyperbaric; isobaric; spinal anaesthesia; DELIVERY; PLAIN; METAANALYSIS; 0.5-PERCENT; ANALGESIA; MORPHINE; FENTANYL; PAIN; MG;
D O I
10.1111/anae.14084
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Both isobaric and hyperbaric bupivacaine have been used for spinal anaesthesia for elective caesarean section, but it is not clear if one is better than the other. The primary objective of this systematic review was to determine the effectiveness and safety of hyperbaric bupivacaine compared with isobaric bupivacaine administered during spinal anaesthesia for elective caesarean section. We included 10 studies with 614 subjects in the analysis. There was no evidence of differences either in the risk of conversion to general anaesthesia, with a relative risk (95%CI) of 0.33 (0.09-1.17) (very low quality of evidence), or in the need for supplemental analgesia, the relative risk (95%CI) being 0.61 (0.26-1.41) (very low quality of evidence). There was also no evidence of a difference in the use of ephedrine, the amount of ephedrine used, nausea and vomiting, or headache. Hyperbaric bupivacaine took less time to reach a sensory block height of T4, with a mean difference (95%CI) of -1.06 min (-1.80 to -0.31). Due to the rarity of some outcomes, dose variability, use of adjuvant drugs and spinal technique used, future clinical trials should look into using adequate sample size to investigate the primary outcome of the need for supplemental analgesia.
引用
收藏
页码:499 / 511
页数:13
相关论文
共 50 条
  • [31] General vs. regional anaesthesia for emergency caesarean section; a retrospective chart review
    Hein, Anette
    Thalen, David
    Eriksson, Ylva
    Jakobsson, Jan
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2017, 61 (08) : 1013 - 1014
  • [32] Supplementary oxygen administration for elective Caesarean section under spinal anaesthesia
    Cogliano, MS
    Graham, AC
    Clark, VA
    ANAESTHESIA, 2002, 57 (01) : 66 - 69
  • [33] Supplementary oxygen during elective caesarean section under spinal anaesthesia
    Salwanis, Wan
    Ismail, Wan
    Lee, Choon Yee
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 : 197 - 197
  • [34] Combined spinal and epidural anaesthesia for an elective Caesarean section in a patient with achondroplasia
    Rukewe, A.
    Morhason-Bello, I. O.
    Fatiregun, A.
    Orji, M.
    SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2012, 18 (06) : 348 - 350
  • [35] A comparison of a 0.5% isobaric bupivacaine-4% hyperbaric mepivacaine mixture and 0.5% hyperbaric bupivacaine for single-dose spinal anaesthesia
    Eckert, S
    Standl, T
    ANAESTHESIST, 1997, 46 (02): : 121 - 125
  • [36] Speed of onset of spinal vs general anaesthesia for caesarean section
    Buettner, A. U.
    ANAESTHESIA, 2013, 68 (11) : 1203 - 1203
  • [37] A comparative study of low doses of isobaric or hyperbaric bupivacaine for CSE anesthesia for elective cesarean section
    Cerda, SE
    Leyton, P
    Hidalgo, GA
    Allen, C
    Escobar, JA
    Parra, VM
    Cumsille, F
    ANESTHESIOLOGY, 2005, 102 (05) : A14 - A14
  • [38] A systematic review of phenylephrine vs. noradrenaline for the management of hypotension associated with neuraxial anaesthesia in women undergoing caesarean section
    Heesen, M.
    Hilber, N.
    Rijs, K.
    Rossaint, R.
    Girard, T.
    Mercier, F. J.
    Klimek, M.
    ANAESTHESIA, 2020, 75 (06) : 800 - 808
  • [39] Comparison of three different doses (7.5mg, 8.75mg and 10mg) of 0.5% hyperbaric bupivacaine in spinal anaesthesia for elective caesarean section
    Reddy, Reddivari Nitya
    ANESTHESIA AND ANALGESIA, 2021, 133 (3S_SUPPL): : 1100 - 1100
  • [40] Effects on hypotension incidence: hyperbaric, isobaric, and combinations of bupivacaine for spinal anesthesia in cesarean section
    Yurtlu, Bulent Serhan
    Hanci, Volkan
    Okyay, Rahsan Dilek
    Bostankolu, Selime Evrim
    Kayhan, Gulay Erdogan
    Hakimoglu, Sedat
    Ayoglu, Hilal
    Arikan, Inan Ilker
    Bayar, Ulku
    Turan, Isil Ozkocak
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2012, 42 (02) : 307 - 313