KnoWind: A database-oriented approach to determine the pedestrian level wind environment around buildings

被引:0
|
作者
Visser, GT [1 ]
Folkers, CJ [1 ]
Weenk, A [1 ]
机构
[1] TNO, Inst Environm Sci Energy Res & Proc Innovat, Dept Environm Qual, Apeldoorn, Netherlands
关键词
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High buildings generally have an adverse effect on the wind conditions in their immediate vicinity, sometimes giving rise to dangerous wind conditions. So far, the whole issue is hardly considered in the design stage since there are no easy tools available for use by designers. To fill this gap, a user-friendly database-oriented computer programme has been developed, called KnoWind, with which the pedestrian level wind environment around building can be determined easily. Complex building configurations must be schematised to their main dimensions. The roughness of the environment of the building under consideration is taken into account, but not adjacent buildings. With remarkable accuracy, the programme can be used to predict the potential wind nuisance and wind danger around buildings in simple and even complex situations, provided that the building under consideration is higher than the surrounding buildings. The user-friendly set-up, the simple input and the fast calculations make the programme suitable as a tool for laymen in the field of wind engineering and for quick scans of potential wind problems.
引用
收藏
页码:805 / 811
页数:7
相关论文
共 50 条
  • [31] Traceable P2P record exchange: A database-oriented approach
    Li F.
    Iida T.
    Ishikawa Y.
    Front. Comput. Sci. China, 2008, 3 (257-267): : 257 - 267
  • [32] Integrated Impacts of Building Space Ratio and Wind Direction on Pedestrian-level Wind Environment around High-rise Buildings with Equilateral Triangle Arrangement
    Cui, H.
    Ma, M.
    Li, J.
    Yang, L.
    Han, Z.
    Liu, Q.
    JOURNAL OF APPLIED FLUID MECHANICS, 2024, 17 (09) : 2016 - 2027
  • [33] Pedestrian-level wind conditions around buildings:Review of wind-tunnel and CFD techniques and their accuracy for wind comfort assessment
    B.Blocken
    T.Stathopoulos
    J.P.A.J.van Beeck
    侯恩哲
    建筑节能, 2016, 44 (05) : 20 - 20
  • [34] Pedestrian-level wind conditions around buildings: Review of wind-tunnel and CFD techniques and their accuracy for wind comfort assessment
    Blocken, B.
    Stathopoulos, T.
    van Beeck, J. P. A. J.
    BUILDING AND ENVIRONMENT, 2016, 100 : 50 - 81
  • [35] Experimental Investigation on Pedestrian-level Wind Environment Around a High-rise Building
    Xie Z.
    Lu Y.
    Yu X.
    Tongji Daxue Xuebao/Journal of Tongji University, 2020, 48 (12): : 1726 - 1732
  • [36] Assessment of pedestrian level wind environment of a group of high-rise buildings based on numerical simulation
    Quan, Yong
    Wang, Shuo
    Gu, Ming
    Zheng, Deqian
    Zhang, Aishe
    SUSTAINABLE CITIES DEVELOPMENT AND ENVIRONMENT, PTS 1-3, 2012, 209-211 : 1553 - 1559
  • [37] Pedestrian level wind environment assessment around group of high-rise cross-shaped buildings: Effect of building shape, separation and orientation
    Iqbal, Qureshi M. Zahid
    Chan, A. L. S.
    BUILDING AND ENVIRONMENT, 2016, 101 : 45 - 63
  • [38] PIV study on characteristics of pedestrian-level fluctuating wind speeds around square buildings with different heights
    Lin, Qiang
    Yang, Qingshan
    Tamura, Yukio
    BUILDING AND ENVIRONMENT, 2025, 267
  • [39] Evaluation of pedestrian winds around tall buildings by numerical approach
    B. M. Wang
    H. Z. Liu
    K. Chen
    J. G. Sang
    G. C. Woo
    B. Y. Zhang
    Meteorology and Atmospheric Physics, 2004, 87 : 133 - 142
  • [40] Evaluation of pedestrian winds around tall buildings by numerical approach
    Wang, BM
    Liu, HZ
    Chen, K
    Sang, JG
    Woo, GC
    Zhang, BY
    METEOROLOGY AND ATMOSPHERIC PHYSICS, 2004, 87 (1-3) : 133 - 142