Efficiency evaluation of a 13C Magnetic Resonance birdcage coil: Theory and comparison of four methods

被引:5
|
作者
Giovannetti, Giulio [1 ,2 ]
Frijia, Francesca [2 ]
Hartwig, Valentina [1 ,2 ]
Menichetti, Luca [1 ,2 ]
Ardenkjaer-Larsen, Jan Henrik [3 ,4 ]
De Marchi, Daniele [2 ]
Positano, Vincenzo [2 ]
Landini, Luigi [2 ,5 ]
Lombardi, Massimo [2 ]
Santarelli, Maria Filomena [1 ,2 ]
机构
[1] CNR, Inst Clin Physiol, I-56124 Pisa, Italy
[2] Fdn G Monasterio CNR Reg Toscana, I-56124 Pisa, Italy
[3] GE Healthcare, DK-2605 Brondby, Denmark
[4] Tech Univ Denmark, Dept Elect Engn, DK-2800 Lyngby, Denmark
[5] Univ Pisa, Dept Informat Engn, I-56126 Pisa, Italy
关键词
Magnetic Resonance; Radiofrequency coils; Coil efficiency;
D O I
10.1016/j.measurement.2013.03.015
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Radiofrequency coils in Magnetic Resonance systems are used to produce a homogeneous B-1 field for exciting the nuclei and to pick up the signals emitted by the nuclei with high signal-to-noise ratio. Accordingly, coil performance affects strongly the quality of the obtained data and images. Coil efficiency, defined as the B-1 magnetic field induced at a given point on the square root of supplied power P, is an important parameter that characterizes coil performance, since by maximizing efficiency will also maximize the signal-to-noise ratio. This work describes and compares four methods for coil efficiency estimation, based on different theoretical approaches. Three methods allow efficiency measurement by using "probe techniques'' (perturbing loop, perturbing sphere and pick-up coil), which can be used both on the bench and inside the scanner, while an "NMR technique'' has been employed for comparison purpose. Methods were tested on a C-13 birdcage coil tuned at 32.13 MHz. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2201 / 2205
页数:5
相关论文
共 50 条
  • [31] Dual Tuned Switch for Dual Resonance 1H/13C MRI Coil
    Saleh, Gameel
    Abuelhaija, Ashraf
    2021 IEEE INTERNATIONAL IOT, ELECTRONICS AND MECHATRONICS CONFERENCE (IEMTRONICS), 2021, : 207 - 213
  • [32] Development of a Proton-Frequency-Transparent Birdcage Radiofrequency Coil for In Vivo 13C MRS/MRSI Study in a 3.0 T MRI System
    Yoon, Jun-Sik
    Kim, Jong-Min
    Chung, Han-Jae
    Jeong, You-Jin
    Jeong, Gwang-Woo
    Park, Ilwoo
    Kim, Gwang-Won
    Oh, Chang-Hyun
    APPLIED SCIENCES-BASEL, 2021, 11 (23):
  • [33] 13C NUCLEAR MAGNETIC RESONANCE STUDIES .13. 13C CARBONYL CARBON SHIELDINGS OF SOME BETA,GAMMA-UNSATURATED KETONES
    GURUDATA
    STOTHERS, JB
    CANADIAN JOURNAL OF CHEMISTRY, 1969, 47 (19): : 3601 - &
  • [34] Effect of Distance on Optimum Transfer Efficiency for the Four-coil Magnetic Coupled Resonance System
    Gong, Lijiao
    Li, Xinheng
    Chao, Xuewei
    Zuo, Jing
    Li, Yang
    JOURNAL OF MAGNETICS, 2017, 22 (03) : 491 - 496
  • [35] Hyperpolarized 13C magnetic resonance metabolic imaging: application to brain tumors
    Park, Ilwoo
    Larson, Peder E. Z.
    Zierhut, Matthew L.
    Hu, Simon
    Bok, Robert
    Ozawa, Tomoko
    Kurhanewicz, John
    Vigneron, Daniel B.
    VandenBerg, Scott R.
    James, C. David
    Nelson, Sarah J.
    NEURO-ONCOLOGY, 2010, 12 (02) : 133 - 144
  • [37] 13C isotopic enrichment for nuclear magnetic resonance studies of carbohydrates and glycoconjugates
    Live, D
    Silks, LAP
    Schmidt, J
    NUCLEAR MAGNETIC RESONANCE OF BIOLOGICA MACROMOLECULES, PT A, 2001, 338 : 305 - 319
  • [38] Analyses of mitochondrial metabolism in diseases: a review on 13C magnetic resonance tracers
    Sharma, Gaurav
    Duarte, Sergio
    Shen, Qingyang
    Khemtong, Chalermchai
    RSC ADVANCES, 2024, 14 (51) : 37871 - 37885
  • [39] NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY 13C SPECTRUM OF A DIMER OF CYCLOOCTATETRAENE(1)
    GROHMANN, K
    GRUTZNER, JB
    ROBERTS, JD
    TETRAHEDRON LETTERS, 1969, (12) : 917 - &
  • [40] NUCLEAR MAGNETIC DOUBLE RESONANCE APPARATUS FOR CHEMICAL SHIFT MEASUREMENTS ON 13C
    ALLEN, JH
    BECCONSALL, JK
    TURNER, DW
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1964, 41 (11): : 673 - &