An ultrasensitive streptavidin-functionalized carbon nanotubes platform for chemiluminescent immunoassay

被引:23
|
作者
Yang, Zhanjun [1 ]
Shen, Juan [1 ]
Li, Juan [1 ]
Zhu, Jing [1 ]
Hu, Xiaoya [1 ]
机构
[1] Yangzhou Univ, Coll Chem & Chem Engn, Jiangsu Key Lab Environm Engn & Monitoring, Yangzhou 225002, Peoples R China
基金
中国国家自然科学基金;
关键词
Carbon nanotubes; Streptavidin; Functionalization; Chemiluminescent; Immunoassay; Tumor marker; ALPHA-FETOPROTEIN; ELECTROCHEMICAL IMMUNOSENSOR; GLUCOSE-OXIDASE; COVALENT IMMOBILIZATION; SIGNAL AMPLIFICATION; ENZYME-IMMUNOASSAY; GOLD NANOPARTICLES; SYSTEM; ELECTRODE; PROTEINS;
D O I
10.1016/j.aca.2013.02.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An ultrasensitive chemiluminescent (CL) immunoassay system was developed for the detection of tumor marker. This sandwich CL assay method was for the first time designed based on a highly efficient streptavidin-functionalized multi-walled carbon nanotubes (MWCNTs) platform. The glass slide was firstly silylanized with 3-gycidoxypropyltrimethoxysilane (GPTMS) to generate surface epoxy group functionality. Subsequently, the MWCNTs/chitosan solution was mixed with streptavidin solution, and a certain amount of the resulting suspension was dropped on the surface of the epoxy-activated glass substrate to form a firm streptavidin-functionalized MWCNTs platform. The biofunctionalized-MWCNTs platform shows large reactive surface area and excellent biocompatibility. The capture antibody can be efficiently immobilized on the biosensing platform surface based on the highly selective recognition of streptavidin to biotinylated antibody. Using alpha-fetoprotein (AFP) as model analyte, the proposed method exhibits wide linear range of 0.001-0.1 ngmL(-1) with a low detection limit down to 0.52 pg mL(-1). The CL immunoassay system displays 7.9-fold increase in the detection sensitivity compared to the immunosensor without using MWCNTs. Moreover, the resulting immunosensor demonstrates excellent specificity, good reproducibility, and acceptable stability. This streptavidin-functionalized MWCNTs platform opens a novel and promising avenue for fabricating ultrasensitive CL immunoassay system. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:85 / 91
页数:7
相关论文
共 50 条
  • [21] Bienzyme Based Biosensing Platform Using Functionalized Carbon Nanotubes
    Jeykumari, D. R. Shobha
    Narayanan, S. Sriman
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (09) : 5411 - 5416
  • [22] Ultrasensitive detection of biomolecules using functionalized multi-walled carbon nanotubes
    Hu, PingAn
    Tanii, Takashi
    Zhang, Guo-Jun
    Hosaka, Takumi
    Ohdomari, Iwao
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (01) : 161 - 166
  • [23] A Flexible Platform of Electrochemically Functionalized Carbon Nanotubes for NADH Sensors
    Heras, Aranzazu
    Vulcano, Fabio
    Garoz-Ruiz, Jesus
    Porcelli, Nicola
    Terzi, Fabio
    Colina, Alvaro
    Seeber, Renato
    Zanardi, Chiara
    SENSORS, 2019, 19 (03)
  • [24] A dual amplification strategy for ultrasensitive electrochemiluminescence immunoassay based on a Pt nanoparticles dotted graphene-carbon nanotubes composite and carbon dots functionalized mesoporous Pt/Fe
    Deng, Wenping
    Liu, Fang
    Ge, Shenguang
    Yu, Jinghua
    Yan, Mei
    Song, Xianrang
    ANALYST, 2014, 139 (07) : 1713 - 1720
  • [25] Multilayers enzyme-coated carbon nanotubes as biolabel for ultrasensitive chemiluminescence immunoassay of cancer biomarker
    Bi, Sai
    Zhou, Hong
    Zhang, Shusheng
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (10): : 2961 - 2966
  • [26] Electrochemically functionalized single-walled carbon nanotubes for ultrasensitive detection of BTEX vapors
    Sarkar, Tapan
    Srinives, Sira
    MICROELECTRONIC ENGINEERING, 2021, 247
  • [27] Ultrasensitive detection of lead (II) based on fluorescent aptamer-functionalized carbon nanotubes
    Taghdisi, Seyed Mohammad
    Emrani, Somayeh Sarreshtehdar
    Tabrizian, Kaveh
    Ramezani, Mohammad
    Abnous, Khalil
    Emrani, Ahmad Sarreshtehdar
    ENVIRONMENTAL TOXICOLOGY AND PHARMACOLOGY, 2014, 37 (03) : 1236 - 1242
  • [28] Signal amplification of streptavidin-horseradish peroxidase functionalized carbon nanotubes for amperometric detection of attomolar DNA
    Gao, Wenchao
    Dong, Haifeng
    Lei, Jianping
    Ji, Hanxu
    Ju, Huangxian
    CHEMICAL COMMUNICATIONS, 2011, 47 (18) : 5220 - 5222
  • [29] A streptavidin functionalized graphene oxide/Au nanoparticles composite for the construction of sensitive chemiluminescent immunosensor
    Yang, Zhanjun
    Luo, Shufen
    Li, Juan
    Shen, Juan
    Yu, Suhua
    Hu, Xiaoya
    Dionysiou, Dionysios D.
    ANALYTICA CHIMICA ACTA, 2014, 839 : 67 - 73
  • [30] Plant peroxidases-catalyzed detection systems and their use in ultrasensitive chemiluminescent enzyme immunoassay
    Sakharov, Ivan Yu.
    Vdovenko, Marina M.
    LUMINESCENCE, 2012, 27 (02) : 159 - 159