Analysis of acrylamide in drinking water by SPE and GC-MS

被引:12
|
作者
Canbay, Hale Secilmis [1 ]
Dogantuerk, Mahmut [2 ]
机构
[1] Burdur Mehmet Akif Ersoy Univ, Dept Bioengn, Fac Engn & Architecture, Burdur, Turkey
[2] Burdur Mehmet Akif Ersoy Univ, Res & Practice Ctr, Burdur, Turkey
关键词
Drinking water; Acrylamide; SPE; GC-MS; CHROMATOGRAPHY; MICROEXTRACTION; DERIVATIZATION; ONCOGENICITY; INJECTION; SAMPLES; RATS;
D O I
10.1007/s13201-019-0918-8
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
The present study aimed to evaluate the levels of acrylamide in drinking water by solid phase extraction (SPE). After SPE, water extracts were analyzed using gas chromatography-mass spectrometry (GC-MS) system. Thirty drinking water samples were analyzed in the study. Acrylamide was detected in 12 samples. The levels of acrylamide in drinking water samples were less than 85ngl(-1). The limit of detection and limit of quantification were 4 and 13.20ngl(-1), respectively.