Application of common transformers faults diagnosis methods on biodegradable oil-filled transformers

被引:13
|
作者
Muhamad, N. A. [1 ]
Phung, B. T. [2 ]
Blackburn, T. R. [2 ]
机构
[1] Univ Technol Malaysia, Skudai, Johor, Malaysia
[2] Univ New S Wales, Kensington, NSW 2033, Australia
关键词
Oil-filled transformers; Biodegradable oil; Mineral oil; Transformer faults; Insulation diagnostics; Dissolved gas-in-oil analysis; Partial discharge;
D O I
10.1007/s00202-012-0232-z
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Due to environmental concerns regarding the use of mineral oil, biodegradable oil is increasingly being used as an alternative dielectric fluid. This paper presents results of experiments performed in the laboratory on the use of biodegradable oils for transformer application. The investigations cover two important diagnostic techniques for insulation assessment: (i) an investigation of partial discharge (PD) activity and characteristics in such oils and (ii) an investigation of the standard hydrocarbon dissolved gas products produced due to transformer faults. The fundamental aim of the investigation was to provide information as to whether the existing analysis techniques of PD fault pattern recognition and dissolved gas analysis methods, developed for mineral oil, are valid when used for insulation assessment with biodegradable transformer oil. The experiments were conducted on test samples to simulate three common types of transformer faults: low-energy PDs, high-energy arcing/sparking, and overheating. For the purpose of comparison, the same tests were performed using a mineral oil (Shell Diala MX) and a biodegradable oil (Envirotemp FR3). Also, each oil type was tested at three different moisture levels and with or without the presence of solid insulating materials (pressboard). PD activity was monitored using the standard IEC60270 phase-resolved analysis method. The fault gases produced were extracted and analysed by standard gas chromatography methods. Test results indicate that the PD phase resolved patterns are, in general, similar for the two oil types and thus existing PD pattern interpretations can be used to distinguish different types of PD faults, e.g. corona versus surface discharges. However, the values of various discharge quantities (PD magnitudes, repetition rate, current, etc) are very different under the same test condition. The quantities and the trend of dissolved gases for faults in biodegradable oil are substantially different compared with mineral oil. For the PD fault, biodegradable oil was found to release only a limited number of gases. For arcing and overheating faults, the main key gas produced is different between the two oils. Also, the presence of cellulosic materials such as pressboard influences the extent of hydrocarbon gases dissolved in the oil. It was found that for biodegradable oil, fewer amounts of gases are produced as the oil gets wetter.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [1] Application of common transformers faults diagnosis methods on biodegradable oil-filled transformers
    N. A. Muhamad
    B. T. Phung
    T. R. Blackburn
    Electrical Engineering, 2012, 94 : 207 - 216
  • [2] Faults Identification of Biodegradable Oil-filled Transformers Based on Polarization and Depolarization Current Measurement (PDC) Method
    Muhamad, N. A.
    Suleiman, A. A.
    Phung, B. T.
    Blackburn, T. R.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2013, 20 (06) : 2299 - 2306
  • [3] On-line diagnostics of oil-filled transformers
    Varl, A
    PROCEEDINGS OF THE 2002 IEEE 14TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS, 2002, : 253 - 257
  • [4] Rapid Assessment of the Operational Status of the Oil-filled Transformers
    Levin, Vladimir
    Kerimkulov, Nurzhan
    2016 11TH INTERNATIONAL FORUM ON STRATEGIC TECHNOLOGY (IFOST), PTS 1 AND 2, 2016,
  • [5] Model for Predictive Control of Temperature in Oil-filled Transformers
    Mastorakis, Nikos E.
    Bulucea, Cornelia Aida
    Manolea, Gheorghe
    Popescu, Marius Constantin
    Perescu-Popescu, Liliana
    PROCEEDINGS OF THE 11TH WSEAS INTERNATIONAL CONFERENCE ON AUTOMATIC CONTROL, MODELLING AND SIMULATION: CONTROLLING, MODELLING AND SIMULATION, 2009, : 157 - +
  • [6] DE-SLUDGING ENERGIZED OIL-FILLED TRANSFORMERS
    PARRISH, RH
    KELLY, JJ
    PLANT ENGINEERING, 1979, 33 (20) : 101 - 105
  • [7] Improvement for diagnosing internal abnormalities in oil-filled transformers
    Zama, Shigeyuki
    Kobayashi, Takayuki
    Ikeda, Jiro
    Eto, Atsushi
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 941 - 944
  • [8] Fault diagnosis for oil-filled transformers using voting based extreme learning machine
    Liwei Zhang
    Jian Zhai
    Cluster Computing, 2019, 22 : 8363 - 8370
  • [9] PARTICLE CONTAMINATION LEVELS IN OIL-FILLED LARGE POWER TRANSFORMERS
    OOMMEN, TV
    PETRIE, EM
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (05): : 1459 - 1465
  • [10] Fault diagnosis for oil-filled transformers using voting based extreme learning machine
    Zhang, Liwei
    Zhai, Jian
    CLUSTER COMPUTING-THE JOURNAL OF NETWORKS SOFTWARE TOOLS AND APPLICATIONS, 2019, 22 (Suppl 4): : S8363 - S8370