Calibrating the uptake kinetics of semipermeable membrane devices in water:: Impact of hydrodynamics

被引:99
|
作者
Vrana, B [1 ]
Schüürmann, G [1 ]
机构
[1] UFZ Helmholtz Ctr Environm Res, Dept Chem Ecotoxicol, D-04318 Leipzig, Germany
关键词
D O I
10.1021/es0100625
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of lipid-containing semipermeable membrane devices (SPMDs) is becoming commonplace, but the potential effects of environmental variables affecting the accumulation of contaminants into SPMDs had not been characterized sufficiently, yet. To characterize the effect of hydrodynamic conditions on the contaminant uptake kinetics, accumulation of pentachlorobenzene, hexachlorobenzene, and hexachlorocyclohexane isomers from water into SPMD was studied at various water flow rates, The accumulation kinetics of hydrophobic compounds (log K-ow > 4) are governed by the aqueous boundary layer in linear flow velocity range from 0.06 to 0.28 cm s(-1) and sensitive to slight changes in flow rate. The effect of flow velocity on the exchange kinetics increases with increasing hydrophobicity. Under faster, but still laminar flow conditions (0.28-1.14 cm s(-1)), the sensitivity to changes in flow decreases to a nonsignificant level for the substances under consideration. The results of this study confirm that the use of the laboratory-derived calibration data for estimation of analyte concentrations in the ambient environment is limited unless flow-sensitive performance reference compounds are used.
引用
收藏
页码:290 / 296
页数:7
相关论文
共 50 条
  • [21] PASSIVE SAMPLING OF WATER AND COASTAL AIR VIA SEMIPERMEABLE-MEMBRANE DEVICES
    PREST, HF
    JACOBSEN, LA
    HUCKINS, JN
    CHEMOSPHERE, 1995, 30 (07) : 1351 - 1361
  • [22] Field uptake rates of hydrophobic organic contaminants by semipermeable membrane devices: environmental monitoring considerations
    Sanchez-Hernandez, JC
    Borghini, F
    Corral, A
    Grimalt, JO
    JOURNAL OF ENVIRONMENTAL MONITORING, 2004, 6 (11): : 919 - 925
  • [23] Calibration and field verification of semipermeable membrane devices for measuring polycyclic aromatic hydrocarbons in water
    Luellen, DR
    Shea, D
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2002, 36 (08) : 1791 - 1797
  • [24] LIPID-CONTAINING SEMIPERMEABLE-MEMBRANE DEVICES FOR MONITORING ORGANIC CONTAMINANTS IN WATER
    HUCKINS, JN
    MANUWEERA, GK
    PETTY, JD
    MACKAY, D
    LEBO, JA
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1993, 27 (12) : 2489 - 2496
  • [25] An approach for assessment of water quality using semipermeable membrane devices (SPMDs) and bioindicator tests
    Petty, JD
    Jones, SB
    Huckins, JN
    Cranor, WL
    Parris, JT
    McTague, TB
    Boyle, TP
    CHEMOSPHERE, 2000, 41 (03) : 311 - 321
  • [26] Caged mussels and semipermeable membrane devices as indicators of organic contaminant uptake in Dorchester and Duxbury Bays, Massachusetts
    Peven, CS
    Uhler, AD
    Querzoli, FJ
    ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 1996, 15 (02) : 144 - 149
  • [27] Purification of triolein for use in semipermeable membrane devices (SPMDs)
    Lebo, JA
    Almeida, FV
    Cranor, WL
    Petty, JD
    Huckins, JN
    Rastall, A
    Alvarez, DA
    Mogensen, BB
    Johnson, BT
    CHEMOSPHERE, 2004, 54 (08) : 1217 - 1224
  • [28] Quality control associated with use of semipermeable membrane devices
    DeVita, WM
    Crunkilton, RL
    ENVIRONMENTAL TOXICOLOGY AND RISK ASSESSMENT: SEVENTH VOLUME, 1998, 1333 : 237 - 245
  • [29] Quality control associated with use of semipermeable membrane devices
    Environmental Task Force Program, Trace Organics Laboratory, University of Wisconsin, Stevens Point, WI 54481, United States
    不详
    ASTM Spec Tech Publ, 1333 (237-245):
  • [30] HPLC-PFD determination of priority pollutant PAHs in water, sediment, and semipermeable membrane devices
    Williamson, KS
    Petty, JD
    Huckins, JM
    Lebo, JA
    Kaiser, EA
    CHEMOSPHERE, 2002, 49 (07) : 703 - 715