Comparison of a hydrophilic and a hydrophobic apodized diffractive multifocal intraocular lens

被引:15
|
作者
van der Linden, Jan Willem
van der Meulen, Ivanka J.
Mourits, Maarten P.
Lapid-Gortzak, Ruth
机构
[1] Department of Ophthalmology, Academic Medical Center, University of Amsterdam, Meibergdreef 9
[2] Retina Total Eye Care, Driebergen
关键词
RETINAL STRAYLIGHT; IMPLANTATION; OUTCOMES;
D O I
10.1007/s10792-013-9727-5
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To compare outcomes between a new design apodized diffractive hydrophilic multifocal intraocular lens (IOL) (Seelens MF; study group), and a well-known apodized diffractive hydrophobic multifocal IOL (SN6AD1; control group). A comparative case series comparing refractive and visual outcomes at distance and near. Patient satisfaction with a validated questionnaire, dysphotopsia and straylight measurement scores were recorded at 3 months post-operatively. The study group comprised 48 eyes and the control group 37 eyes. At 3 months post-operatively the mean uncorrected distance visual acuity (UDVA) was not statistically significant different between the study group and the control group (0.02 +/- A 0.07 logMAR [SD] vs 0.04 +/- A 0.09 logMAR). Corrected distance visual acuity (CDVA) was statistically significantly better with the study lens (-0.04 +/- A 0.05 logMAR vs -0.01 +/- A 0.04 logMAR (p < 0.019). There was no clinical or statistical significant difference at the 40 cm distance (0.09 +/- A 0.12 logMAR vs 0.08 +/- A 0.09 logMAR). The study group had statistically significant better uncorrected near acuity at 50 and 60 cm distances (p < 0.03 and p < 0.007, respectively). In terms of satisfaction the lenses performed equally. Halos were seen less often with the study lens. Straylight, as a parameter for visual quality, was significantly less with the study lens. Conclusion: The Seelens MF performs equally as well as the well-known SN6AD1 for UCDA and CDVA. The Seelens MF performs better at intermediate distance, and seems to allow for better depth of focus, and increased visual quality. More study is needed to corroborate the last finding.
引用
收藏
页码:493 / 500
页数:8
相关论文
共 50 条
  • [21] Double-pass system analysis of the visual outcomes and optical performance of an apodized diffractive multifocal intraocular lens
    Moreno, Luis J.
    Pinero, David P.
    Alio, Jorge L.
    Fimia, Antonio
    Plaza, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (12): : 2048 - 2055
  • [22] Refractive lens exchange with a multifocal diffractive aspheric intraocular lens
    Ferrer-Blasco, Teresa
    Garcia-Lazaro, Santiago
    Albarran-Diego, Cesar
    Belda-Salmeron, Lurdes
    Montes-Mico, Robert
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2012, 75 (03) : 192 - 196
  • [23] Comparison of pseudoaccommodation and visual quality between a diffractive and refractive multifocal intraocular lens
    Weghaupt, H
    Pieh, S
    Skorpik, C
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1998, 24 (05): : 663 - 665
  • [24] Apodized diffractive versus refractive multifocal intraocular lenses: Optical and visual evaluation
    Zelichowska, Beata
    Rekas, Marek
    Stankiewicz, Andrzej
    Cervino, Alejandro
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (12): : 2036 - 2042
  • [25] Comparative Analysis of a New Hybrid EDOF-Multifocal Diffractive Intraocular Lens with a Trifocal Diffractive Intraocular Lens
    Ozturkmen, Cem
    Kesim, Cem
    Karadeniz, Pinar Gunel
    Sahin, Afsun
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2961 - 2966
  • [26] Clinical outcomes of a new diffractive multifocal intraocular lens
    Baha Toygar
    Ozge Yabas Kiziloglu
    Okan Toygar
    Ali Murat Hacimustafaoglu
    International Journal of Ophthalmology, 2017, (12) : 1844 - 1850
  • [27] In vitro optical quality differences between multifocal apodized diffractive intraocular lenses
    Montes-Mico, Robert
    Madrid-Costa, David
    Ruiz-Alcocer, Javier
    Ferrer-Blasco, Teresa
    Pons, Alvaro M.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (06): : 928 - 936
  • [28] Diffractive multifocal intraocular lens interferes with intraoperative view
    Yoshino, Mami
    Inoue, Makoto
    Kitamura, Nae
    Bissen-Miyajima, Hiroko
    CLINICAL OPHTHALMOLOGY, 2010, 4 : 467 - 469
  • [29] Clinical evaluation of a multifocal aspheric diffractive intraocular lens
    Schmickler, Stefanie
    Palomino Bautista, Carlos
    Goes, Frank
    Shah, Sunil
    Wolffsohn, James S.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (12) : 1560 - 1564
  • [30] DIFFRACTIVE MULTIFOCAL INTRAOCULAR-LENS IMAGE QUALITY
    SIMPSON, MJ