Electrochemical biosensor based on self-assembled monolayers modified with gold nanoparticles for detection of HER-3

被引:46
|
作者
Canbaz, Mehmet Cetin [1 ]
Simsek, Cigdem Sayikli [1 ]
Sezginturk, Mustafa Kemal [1 ]
机构
[1] Namik Kemal Univ, Fac Sci & Arts, Dept Chem, Div Biochem, Tekirdag, Turkey
关键词
Cancer biomarkers; HER-3; Anti-HER-3; Single frequency impedance; Biosensor; GROWTH-FACTOR RECEPTOR; BREAST-CANCER; EXPRESSION; DISPERSION; ANTIBODY; THERAPY; FAMILY;
D O I
10.1016/j.aca.2014.01.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed a new immunological biosensor for ultrasensitive quantification of human epidermal growth factor receptor-3(HER-3). In order to construct the biosensor, the gold electrode surface was layered with, hexanedithiol, gold nanoparticles, and cysteamine, respectively. Anti-HER-3 antibody was covalently attached to cysteamine by glutaraldehyde and used as a bioreceptor in a biosensor system for the first time by this study. Surface characterization was obtained by means of electrochemical impedance spectroscopy and voltammetry. The proposed biosensor showed a good analytical performance for the detection of HER-3 ranging from 0.2 to 1.4 pg mL(-1). Kramers-Kronig transform was performed on the experimental impedance data. Moreover, in an immunosensor system, the single frequency impedance technique was firstly used for characterization of interaction between HER-3 and anti-HER-3. Finally the presented biosensor was applied to artificial serum samples spiked with HER-3. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:31 / 38
页数:8
相关论文
共 50 条
  • [31] DNA Electrochemical Biosensor Based on Au Nanoparticles Self-Assembled Au Electrode
    Liu, Yan
    Dai, Zhao
    Xu, Shichao
    Zhang, Jimei
    Zheng, Guo
    Zhang, Qingyin
    Chen, Guangping
    SOFT MAGNETIC MATERIALS, 2011, 298 : 78 - +
  • [32] Self-assembled multilayer of gold nanoparticles for amplified electrochemical detection of cytochrome c
    Zhao, Jing
    Zhu, Xiaoli
    Li, Ting
    Li, Genxi
    ANALYST, 2008, 133 (09) : 1242 - 1245
  • [33] Electrochemical reduction of bonded oxygen in oxyhemoglobin at gold electrodes modified by self-assembled cysteamine monolayers
    Ruan, CM
    Chen, XH
    Fang, Y
    Deng, JQ
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1998, 45 (02): : 287 - 292
  • [34] Electrochemical behavior of epinephrine at L-cysteine self-assembled monolayers modified gold electrode
    Wang, SF
    Du, D
    Zou, QC
    TALANTA, 2002, 57 (04) : 687 - 692
  • [35] Probing cysteine self-assembled monolayers over gold nanoparticles - Towards selective electrochemical sensors
    Galal, Ahmed
    Atta, Nada F.
    El-Ads, Ekram H.
    TALANTA, 2012, 93 : 264 - 273
  • [36] Benzenedithiol self-assembled monolayers modified gold electrodes for electrochemical determination of tellurium in the presence of selenium
    Howard, Daniel
    Ke, Shan
    ELECTROCHIMICA ACTA, 2012, 80 : 342 - 345
  • [37] A reliable self-assembled peptide based electrochemical biosensor for detection of caspase 3 activity and apoptosis
    Khalilzadeh, Balal
    Shadjou, Nasrin
    Eskandani, Morteza
    Charoudeh, Hojatollah Nozad
    Omidi, Yadollah
    Rashidi, Mohammad-Reza
    RSC ADVANCES, 2015, 5 (72) : 58316 - 58326
  • [38] Enhanced performance of an affinity biosensor interface based on mixed self-assembled monolayers of thiols on gold
    Frederix, F
    Bonroy, K
    Laureyn, W
    Reekmans, G
    Campitelli, A
    Dehaen, W
    Maes, G
    LANGMUIR, 2003, 19 (10) : 4351 - 4357
  • [39] Enhanced performance of an affinity biosensor interface based on mixed self-assembled monolayers of thiols on gold
    Frederix, F. (frederix@imec.be), 1600, American Chemical Society (19):
  • [40] Enlargement of gold nanoparticles on the surface of a self-assembled monolayer modified electrode: A mode in biosensor design
    Zhou, Nandi
    Wang, Jing
    Chen, Ting
    Yu, Zhiguo
    Li, Genxi
    ANALYTICAL CHEMISTRY, 2006, 78 (14) : 5227 - 5230