Combined use of pulsed and color M-mode Doppler echocardiography for the estimation of pulmonary capillary wedge pressure: An empirical approach based on an analytical relation

被引:52
|
作者
Gonzalez-Vilchez, F
Ares, M
Ayuela, J
Alonso, L
机构
[1] Hosp Gen Yague, Secc Cardiol, Serv Internal Med, Burgos 09005, Spain
[2] Hosp Gen Yague, Intens Care Unit, Burgos 09005, Spain
[3] Hosp Laredo, Cardiol Sect, Serv Internal Med, Cantabria, Spain
关键词
D O I
10.1016/S0735-1097(99)00230-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES We sought a noninvasive estimation of pulmonary capillary wedge pressure (Pw) by means of the information obtained from transmitral pulsed Doppler and color M-mode Doppler flow propagation velocity (FPV). BACKGROUND Pulsed Doppler parameters have limited accuracy for the estimation of Pw because they are determined by left atrial pressure and other parameters such as ventricular relaxation. Recently, a good correlation has been found between the rate of ventricular relaxation (tau, tau) and FPV measured by color M-mode Doppler echocardiography. METHODS We studied 20 patients who underwent invasive hemodynamic monitoring. By multilinear regression analysis, the relationships between Pw and Doppler parameters, FPV, and a noninvasive estimate (P-est) based on the Weiss' equation (substituting tau for 1/FPV) were determined. A simplified index based on the results obtained was then tested in an additional group of 34 patients. RESULTS By multiple regression analysis only isovolumic relaxation time (IVRT) (p = 0.0096) and P-est (p = 0.0043) were related to Pw. A derived empirical index, 10(3)/([2. IVRT]+FPV), was strongly correlated with Pw in the entire group according to the regression equation Pw = 4.5 (10(3)/[{2 IVRT} + FPV]) - 9 (r = 0.89, p < 0.0001, [standard error of the estimate] SEE = 3.3 mm Hg). The sensitivity and specificity for the prediction of Pw > 15 mm Hg were 90% and 100%, respectively. CONCLUSIONS The combined use of FPV as a surrogate for tau and IVRT permits a close prediction of Pw. (C) 1999 by the American College of Cardiology.
引用
收藏
页码:515 / 523
页数:9
相关论文
共 48 条
  • [21] Ratio of left ventricular peak E wave velocity and flow propagation velocity assessed by color M-mode Doppler echocardiography: Estimating mean pulmonary capillary wedge pressure in acute myocardial infarction
    Ueno, Y
    Nakamura, Y
    Kinoshita, M
    CIRCULATION, 2000, 102 (18) : 457 - 457
  • [22] Pulsed-Wave Tissue Doppler and Color Tissue Doppler Echocardiography: Calibration with M-Mode, Agreement, and Reproducibility in a Clinical Setting
    Olsen, Niels Thue
    Jons, Christian
    Fritz-Hansen, Thomas
    Mogelvang, Rasmus
    Sogaard, Peter
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (06): : 638 - 644
  • [23] Left ventricular inflow propagation velocity: Comparisons between pulsed wave and color M-mode Doppler echocardiography
    Voon, WC
    Huang, CH
    Lin, TH
    Chu, CS
    Chen, HH
    Sheu, SH
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (12) : 1461 - 1467
  • [24] In vivo validation of pressure-gradient color M-mode images obtained from Doppler echocardiography
    Yotti, R
    Bermejo, J
    Antoranz, C
    Silva, J
    Allue, C
    Moreno, M
    Fernandez, MAG
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 447A - 448A
  • [25] Estimation of the pulmonary capillary wedge pressure from transesophageal pulsed Doppler echocardiography of pulmonary venous flow: Influence of the respiratory cycle during mechanical ventilation
    Girard, F
    Couture, P
    Boudreault, D
    Normandin, L
    Denault, A
    Girard, D
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 1998, 12 (01) : 16 - 21
  • [26] NONINVASIVE ESTIMATION OF PULMONARY CAPILLARY WEDGE PRESSURE FROM PULMONARY VENOUS FLOW USING TRANSESOPHAGEAL DOPPLER-ECHOCARDIOGRAPHY
    SUWA, M
    OTAKE, Y
    ITO, T
    MORIGUCHI, A
    HIROTA, Y
    KAWAMURA, K
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1994, 8 (04): : 207 - 214
  • [27] DETECTION OF PULMONARY-INSUFFICIENCY BY PULSED DOPPLER ECHOCARDIOGRAPHY - VALIDATION, SENSITIVITY, SPECIFICITY AND CORRELATION WITH M-MODE ECHO
    STEVENSON, G
    KAWABORI, I
    GUNTHEROTH, W
    CIRCULATION, 1980, 62 (04) : 251 - 251
  • [28] Determination of pulmonary capillary wedge pressure using pulsed wave Doppler echocardiography: Clinical application of range ambiguity phenomenon
    Su, HM
    Lin, TH
    Voon, WC
    Lai, WT
    Sheu, SH
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2005, 18 (10) : 1023 - 1029
  • [29] Association of left ventricular filling parameters assessed by pulsed wave Doppler and color M-mode Doppler echocardiography with left ventricular pathology, pulmonary congestion, and left ventricular end-diastolic pressure
    Schwammenthal, E
    Popescu, BA
    Popescu, AC
    Di Segni, E
    Guetta, V
    Rath, S
    Eldar, M
    Feinberg, MS
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (04): : 488 - 491
  • [30] NON-INVASIVE ESTIMATION OF PEAK PULMONARY-ARTERY PRESSURE FROM M-MODE ECHOCARDIOGRAPHY
    STEVENSON, G
    KAWABORI, I
    GUNTHEROTH, W
    AMERICAN JOURNAL OF CARDIOLOGY, 1982, 49 (04): : 963 - 963