Influence of dialysate on gastric emptying time in peritoneal dialysis patients

被引:10
|
作者
Van Vlem, BA [1 ]
Schoonjans, RS
Struijk, DG
Verbanck, JJ
Vanholder, RC
Van Biesen, WV
Lefebvre, RA
De Vos, MP
Lameire, NH
机构
[1] State Univ Ghent Hosp, Dept Nephrol, Div Renal, B-9000 Ghent, Belgium
[2] State Univ Ghent Hosp, Div Gastroenterol, Dept Internal Med, B-9000 Ghent, Belgium
[3] Univ Amsterdam, Acad Med Ctr, Div Renal, NL-1105 AZ Amsterdam, Netherlands
[4] Heilig Hart Ziekenhuis, Div Renal, Roeselare, Belgium
[5] State Univ Ghent, Heymans Inst Pharmacol, B-9000 Ghent, Belgium
来源
PERITONEAL DIALYSIS INTERNATIONAL | 2002年 / 22卷 / 01期
关键词
gastric emptying; peritoneal dialysate; glucose; icodextrin; glycerol; amino acids; dyspepsia;
D O I
暂无
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
. Objective: Peritoneal dialysis (PD) patients frequently suffer from dyspeptic complaints such as nausea, vomiting, abdominal distension, early satiety, and anorexia. Gastroparesis might be, at least partially, a source of dyspeptic complaints in PD patients. The aim of the present study was to determine the influence of the presence and composition of dialysate on gastric emptying in PD patients. . Design: Prospective study. . Setting: Renal Division, Department of Internal Medicine, Ghent University Hospital, Belgium. . Patients: Sixty-one PD patients using different dialysate solutions, and 27 healthy volunteers. . Main Outcome Measure: Gastric emptying of solids was assessed by the C-13-octanoic acid breath test. . Results: Gastric emptying was impaired in PD patients, regardless of the composition of dialysate and even if tested with an empty peritoneal cavity. Gastric emptying was significantly slower when glucose-containing dialysate was compared to an empty peritoneal cavity, or when glucose-containing dialysate was compared to icodextrin dialysate. No difference in gastric emptying could be demonstrated between glucose-containing dialysate and dialysate containing a mixture of glycerol and amino acids as osmotic agent. . Conclusions: These findings suggest that the delay in gastric emptying demonstrated in the presence of peritoneal dialysate is not the consequence of a mere volume or pressure effect, but of the absorption of substrate substances with caloric and/or metabolic activity, such as glucose or glycerol and amino acids.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 50 条
  • [21] Bilious peritoneal dialysate in a peritoneal dialysis patient
    Fung, Winston Wing Shing
    Chow, Kai Ming
    Szeto, Cheuk Chun
    [J]. KIDNEY INTERNATIONAL, 2021, 100 (02) : 485 - 485
  • [22] Pharmacokinetics of catcitriol and maxacalcitot administered into peritoneal dialysate bags in peritoneal dialysis patients
    Hamada, C
    Hayashi, K
    Shou, I
    Inaba, M
    Ro, Y
    Io, H
    Maeda, K
    Fukui, M
    Tomino, Y
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2005, 25 (06): : 570 - 575
  • [23] GASTRIC-EMPTYING IN UREMIC PATIENTS UNDERGOING CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS (CAPD)
    PUSTORINO, S
    PITRONE, F
    MILETO, G
    LUZZA, G
    MIGLIORATO, D
    IANNI, G
    TURIANO, S
    TRIPEPI, MG
    FERRAU, O
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1986, 31 (10) : S343 - S343
  • [24] THE EFFECT OF PARICALCITOLON DIALYSATE PROTEIN LOSS IN PERITONEAL DIALYSIS PATIENTS
    Jeronimo, Teresa
    del Peso, Gloria
    Gayo, Lucia
    Guedes, Anabela M.
    Silva, Ana P.
    Neves, Pedro L.
    Selgas, Rafael
    Bajo, Maria A.
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2016, 31 : 1508 - 1508
  • [25] PERITONEAL-DIALYSIS AND DIALYSATE VOLUMES
    KESSLER, J
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1972, 286 (02): : 110 - &
  • [26] Vaginal Leakage of Peritoneal Dialysate in a Peritoneal Dialysis Patient
    Kidir, Veysel
    Altuntas, Atila
    Inal, Salih
    Degirmenci, Bumin
    Sezer, Mehmet Tugrul
    [J]. THERAPEUTIC APHERESIS AND DIALYSIS, 2014, 18 (02) : 211 - 212
  • [27] Effect of increased dialysate volume on peritoneal surface area among peritoneal dialysis patients
    Chagnac, A
    Herskovitz, P
    Ori, Y
    Weinstein, T
    Hirsh, J
    Katz, M
    Gafter, U
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 (10): : 2554 - 2559
  • [28] Peritoneal dialysate fill-volumes and hernia development in a cohort of peritoneal dialysis patients
    Bleyer, AJ
    Casey, MJ
    Russell, GB
    Kandt, M
    Burkart, JM
    [J]. ADVANCES IN PERITONEAL DIALYSIS/1998, VOL 14, 1998, 14 : 102 - 104
  • [29] CYTOKINE LEVELS IN PERITONEAL DIALYSATE OF PATIENTS ON CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS WITH PERITONITIS
    KO, YC
    MUTO, S
    KASAHARA, T
    MUKAIDA, N
    ITOH, Y
    KAWAI, T
    YAMAGISHI, Y
    KUSANO, E
    ASANO, Y
    MATSUSHIMA, K
    [J]. JOURNAL OF LEUKOCYTE BIOLOGY, 1993, : 53 - 53
  • [30] GASTRIC-EMPTYING IN PATIENTS WITH CHRONIC-RENAL-FAILURE ON CONTINUOUS AMBULATORY PERITONEAL-DIALYSIS
    BIRD, NJ
    STREATHER, CP
    ODOHERTY, MJ
    BARTON, IK
    GAUNT, JI
    NUNAN, TO
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 1994, 9 (03) : 287 - 290