An augmented reality system for MR image-guided needle biopsy: Initial results in a swine model

被引:93
|
作者
Wacker, FK [1 ]
Vogt, S
Khamene, A
Jesberger, JA
Nour, SG
Elgort, DR
Sauer, F
Duerk, JL
Lewin, JS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[2] Dept Radiol, Charite, D-12200 Berlin, Germany
[3] Siemens Corp Res, Dept Imaging & Visualizat, Princeton, NJ USA
[4] Johns Hopkins Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
关键词
D O I
10.1148/radiol.2382041441
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate an augmented reality (AR) system in cournbination with a 1.5-T closed-bore magnetic resonance (MR) imager as a navigation tool for needle biopsies. Materials and The experimental protocol had institutional animal care Methods: and use committee approval. Seventy biopsies were performed in phantoms by using 20 tube targets, each with a diameter of 6 min, and 50 virtual targets. The position of the needle tip in AR and MR space was compared in multiple imaging planes, and virtual and real needle tip localization errors were calculated. Ten AR-guided biopsies were performed in three pigs, and the duration of each procedure was determined. After successful puncture, the distance to the target was measured on MR images. The confidence limits for the achieved in-plane hit rate and for lateral deviation were calculated. A repeated measures analysis of variance was used to determine whether the placement error in a particular dimension (x, y, or z) differed Results: For the 50 virtual targets, a mean error of 1.1 mm +/- 0.5 (standard deviation) was calculated. A repeated measures analysis of variance indicated no statistically significant difference (P >.99) in the errors in any particular orientation. For the real targets, all punctures were inside the 6-mm-diameter tube in the transverse plane. The needle depth was within the target plane in 11 biopsy procedures; the mean distance to the center of the target was 2.55 mm. (95% confidence interval: 1.77 mm, 3.34 mm). Fox, nine biopsy procedures, the needle tip was outside the target plane, with a mean distance to the edge of the target plane of 1.5 mm, (range, 0.07-3.46 mm). In the animal experiments, the puncture was successful in all 10 cases, with a mean target-needle distance of 9.6 mm +/- 4.85. The average procedure time was 18 minutes per puncture. Conclusion: Biopsy procedures performed with a combination of a closed-bore MR system and an AR system are feasible and accurate. (c) RSNA, 2006
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [21] Image-guided core needle biopsy of anterior mediastinal masses
    Roebuck, Derek
    Sebire, Neil
    Michalski, Antony
    [J]. PEDIATRIC BLOOD & CANCER, 2007, 49 (04) : 409 - 409
  • [22] Role of image-guided percutaneous needle biopsy in cancer staging
    Gupta, Sanjay
    [J]. SEMINARS IN ROENTGENOLOGY, 2006, 41 (02) : 78 - 90
  • [23] Image-Guided Percutaneous Needle Biopsy in Cancer Diagnosis and Staging
    Gupta, Sanjay
    Madoff, David C.
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 10 (02) : 88 - 101
  • [24] Image-guided percutaneous cutting needle biopsy in difficult locations
    H. Arioz Habibi
    M. Cevener
    S. Yilmaz
    [J]. Japanese Journal of Radiology, 2022, 40 : 560 - 567
  • [25] Image-guided needle biopsy for diagnosis and molecular biology in lymphomas
    de Kerviler, E.
    Benet, C.
    Briere, J.
    de Bazelaire, C.
    [J]. BEST PRACTICE & RESEARCH CLINICAL HAEMATOLOGY, 2012, 25 (01) : 29 - 39
  • [26] Image-guided percutaneous cutting needle biopsy in difficult locations
    Habibi, H. Arioz
    Cevener, M.
    Yilmaz, S.
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2022, 40 (06) : 560 - 567
  • [27] Augmented Reality Guided Needle Biopsy of Soft Tissue: A Pilot Study
    Asgar-Deen, David
    Carriere, Jay
    Wiebe, Ericka
    Peiris, Lashan
    Duha, Aalo
    Tavakoli, Mahdi
    [J]. FRONTIERS IN ROBOTICS AND AI, 2020, 7
  • [28] An augmented reality system for ultrasound guided needle biopsies
    Sauer, F
    Khamene, A
    Bascle, B
    Vogt, S
    [J]. MEDICINE MEETS VIRTUAL REALITY 02/10: DIGITAL UPGRADES: APPLYING MOORES LAW TO HEALTH, 2002, 85 : 455 - 460
  • [29] Percutaneous Image-Guided Biopsy of the Musculoskeletal System
    Welch, Brian T.
    Welch, Timothy J.
    [J]. TECHNIQUES IN VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 14 (03) : 110 - 117
  • [30] MR image-guided surgical robotic system
    Hashizume, M.
    Yasunaga, T.
    Konishi, K.
    Ieiri, S.
    Tanoue, K.
    Kishi, K.
    Nakamoto, H.
    Ikeda, D.
    [J]. INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2006, 1 : 203 - 205