An augmented reality system for MR image-guided needle biopsy: Initial results in a swine model

被引:93
|
作者
Wacker, FK [1 ]
Vogt, S
Khamene, A
Jesberger, JA
Nour, SG
Elgort, DR
Sauer, F
Duerk, JL
Lewin, JS
机构
[1] Case Western Reserve Univ, Univ Hosp Cleveland, Dept Radiol, Cleveland, OH 44106 USA
[2] Dept Radiol, Charite, D-12200 Berlin, Germany
[3] Siemens Corp Res, Dept Imaging & Visualizat, Princeton, NJ USA
[4] Johns Hopkins Sch Med, Russell H Morgan Dept Radiol & Radiol Sci, Baltimore, MD USA
关键词
D O I
10.1148/radiol.2382041441
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate an augmented reality (AR) system in cournbination with a 1.5-T closed-bore magnetic resonance (MR) imager as a navigation tool for needle biopsies. Materials and The experimental protocol had institutional animal care Methods: and use committee approval. Seventy biopsies were performed in phantoms by using 20 tube targets, each with a diameter of 6 min, and 50 virtual targets. The position of the needle tip in AR and MR space was compared in multiple imaging planes, and virtual and real needle tip localization errors were calculated. Ten AR-guided biopsies were performed in three pigs, and the duration of each procedure was determined. After successful puncture, the distance to the target was measured on MR images. The confidence limits for the achieved in-plane hit rate and for lateral deviation were calculated. A repeated measures analysis of variance was used to determine whether the placement error in a particular dimension (x, y, or z) differed Results: For the 50 virtual targets, a mean error of 1.1 mm +/- 0.5 (standard deviation) was calculated. A repeated measures analysis of variance indicated no statistically significant difference (P >.99) in the errors in any particular orientation. For the real targets, all punctures were inside the 6-mm-diameter tube in the transverse plane. The needle depth was within the target plane in 11 biopsy procedures; the mean distance to the center of the target was 2.55 mm. (95% confidence interval: 1.77 mm, 3.34 mm). Fox, nine biopsy procedures, the needle tip was outside the target plane, with a mean distance to the edge of the target plane of 1.5 mm, (range, 0.07-3.46 mm). In the animal experiments, the puncture was successful in all 10 cases, with a mean target-needle distance of 9.6 mm +/- 4.85. The average procedure time was 18 minutes per puncture. Conclusion: Biopsy procedures performed with a combination of a closed-bore MR system and an AR system are feasible and accurate. (c) RSNA, 2006
引用
收藏
页码:497 / 504
页数:8
相关论文
共 50 条
  • [1] An augmented reality system for image-guided surgery
    Marmulla, R
    Hoppe, H
    Mühling, J
    Eggers, G
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (06) : 594 - 596
  • [2] MR image-guided needle biopsies with a combination of augmented reality and MRI: A pilot study in phantoms and animals
    Wacker, FK
    Vogt, S
    Khamene, A
    Sauer, F
    Wendt, M
    Duerk, JL
    Lewin, JS
    Wolf, KJ
    [J]. CARS 2005: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2005, 1281 : 424 - 428
  • [3] A novel augmented reality system of image projection for image-guided neurosurgery
    Mehran Mahvash
    Leila Besharati Tabrizi
    [J]. Acta Neurochirurgica, 2013, 155 : 943 - 947
  • [4] A novel augmented reality system of image projection for image-guided neurosurgery
    Mahvash, Mehran
    Tabrizi, Leila Besharati
    [J]. ACTA NEUROCHIRURGICA, 2013, 155 (05) : 943 - 947
  • [5] The clinical utility of multimodal MR image-guided needle biopsy in cerebral gliomas
    Yao, Chengjun
    Lv, Shunzeng
    Chen, Hong
    Tang, Weijun
    Guo, Jun
    Zhuang, Dongxiao
    Chrisochoides, Nikos
    Wu, Jinsong
    Mao, Ying
    Zhou, Liangfu
    [J]. INTERNATIONAL JOURNAL OF NEUROSCIENCE, 2016, 126 (01) : 53 - 61
  • [6] Image-based augmented reality model for image-guided surgical simulation
    Zhang, Junyi
    Luo, Shuqian
    [J]. MEDICAL IMAGING AND INFORMATICS, 2008, 4987 : 330 - 339
  • [7] Image-guided percutaneous transthoracic needle biopsy
    Lopez Costa, Carlos
    Gonzalez Moreno, Yoannys
    Frometa Guerra, Adonis
    Miller Dixon, Eric
    [J]. MEDWAVE, 2011, 11 (01):
  • [8] Input System Interface for Image-guided Surgery based on Augmented Reality
    Martins, Silvino
    Vairinhos, Mario
    Eliseu, Sergio
    Borgerson, Janet
    [J]. PROCEEDINGS OF THE 2016 1ST INTERNATIONAL CONFERENCE ON TECHNOLOGY AND INNOVATION IN SPORTS, HEALTH AND WELLBEING (TISHW 2016), 2016,
  • [9] Use of augmented reality for image-guided spine procedures
    Gibby, Jacob
    Cvetko, Steve
    Javan, Ramin
    Parr, Ryan
    Gibby, Wendell
    [J]. EUROPEAN SPINE JOURNAL, 2020, 29 (08) : 1823 - 1832
  • [10] Augmented Reality and Image-Guided Robotic Liver Surgery
    Giannone, Fabio
    Felli, Emanuele
    Cherkaoui, Zineb
    Mascagni, Pietro
    Pessaux, Patrick
    [J]. CANCERS, 2021, 13 (24)