Monte Carlo calculation of the efficiency response of a low-background well-type HPGe detector

被引:34
|
作者
Laborie, JM [1 ]
Le Petit, G [1 ]
Abt, D [1 ]
Girard, M [1 ]
机构
[1] CEA, DAM, Dept Analyse & Surveillance Environm, F-91680 Bruyeres Le Chatel, France
关键词
well-type HPGe detectors; gamma-ray spectrometry; efficiency calibration; Monte Carlo simulation; true coincidence-summing;
D O I
10.1016/S0168-9002(01)00942-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Well-type HPGe detectors are well suited for the analysis of small amounts of environmental samples, as they can combine both low background and high detection efficiency. A low-background well-type detector is installed in the Modane underground Laboratory. In the well geometry, coincidence-summing effects are high and make construction of the full energy peak efficiency curve difficult with the usual calibration standard, especially in the: high energy range. Using the GEANT code, taking into account a detailed description of the detector and the source, efficiency curves have been modelled for several filling heights of the vial. With a special routine, taking into account the decay schemes of the radionuclides corrections have been computed for coincidence-summing effects that occur when measuring samples containing U-238, Th-232 or Cs-134. The results are found to be in good agreement with experimental data. It is shown that triple coincidences effect on counting losses accounts for 7-15% of pair coincidences effect in the case of the 604 and 796 keV lines of Cs-134. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:618 / 630
页数:13
相关论文
共 50 条
  • [21] Monte Carlo simulation of the full energy peak efficiency of an HPGe detector
    Khan, Waseem
    Zhang, Qingmin
    He, Chaohui
    Saleh, Muhammad
    APPLIED RADIATION AND ISOTOPES, 2018, 131 : 67 - 70
  • [22] Study of a Well-Type Ionization Chamber by Monte Carlo Simulation
    Santos, M.
    Takeda, F.
    Pianoschi, T.
    Nicolucci, P.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] Estimation of background spectrum in a shielded HPGe detector using Monte Carlo simulations
    Medhat, M. E.
    Wang, Yifang
    APPLIED RADIATION AND ISOTOPES, 2014, 84 : 13 - 18
  • [24] Analytical formulae for well-type NaI (Tl) and HPGe detectors efficiency computation
    Abbas, MI
    APPLIED RADIATION AND ISOTOPES, 2001, 55 (02) : 245 - 252
  • [25] Characterisation of a well-type NaI(Tl) detector by means of a Monte Carlo simulation for radionuclide metrology application
    Heranudin
    Smith, M. L.
    van Wyngaardt, W. M.
    Guatelli, S.
    Li, E.
    Rosenfeld, A.
    APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [26] Validation of an efficiency calibration procedure for a coaxial n-type and a well-type HPGe detector used for the measurement of environmental radioactivity
    Morera-Gomez, Yasser
    Cartas-Aguila, Hector A.
    Alonso-Hernandez, Carlos M.
    Nunez-Duartes, Carlos
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 818 : 51 - 56
  • [27] On the use of mercury as a means of locating background sources in ultra low-background HPGe-detector systems
    Hult, M.
    Gasparro, J.
    Lindahl, P.
    Marissens, G.
    Fessler, A.
    Johnston, Peter N.
    APPLIED RADIATION AND ISOTOPES, 2008, 66 (6-7) : 829 - 834
  • [28] BACKGROUND SPECTRUM CHARACTERISTICS OF THE HPGE DETECTOR LONG-TERM MEASUREMENT IN THE BELGRADE LOW-BACKGROUND LABORATORY
    Banjanac, Radomir
    Udovicic, Vladimir
    Jokovic, Dejan
    Maletic, Dimitrije
    Veselinovic, Nikola
    Savic, Mihailo
    Dragic, Aleksandar
    Anicin, Ivan
    RAD 2015: THE THIRD INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH, 2015, : 151 - 153
  • [29] Accurate calculation of well-type detector geometrical efficiency using sources with different shapes and geometries
    Badawi, M. S.
    JOURNAL OF INSTRUMENTATION, 2015, 10
  • [30] Efficiency transfer in the calibration of a coaxial p-type HpGe detector using the Monte Carlo method
    Vargas, MJ
    Díaz, NC
    Sánchez, DP
    APPLIED RADIATION AND ISOTOPES, 2003, 58 (06) : 707 - 712