Tracing Phosphate Ions Generated during Loop-Mediated Isothermal Amplification for Electrochemical Detection of Nosema bombycis Genomic DNA PTP1

被引:61
|
作者
Xie, Shunbi [1 ]
Yuan, Yali [1 ]
Chai, Yaqin [1 ]
Yuan, Ruo [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, State Key Lab Silkworm Genome Biol, Chongqing 400715, Peoples R China
基金
中国博士后科学基金;
关键词
QUANTITATIVE DETECTION; NUCLEIC-ACIDS; LAMP; POINT; CARE; MOLYBDOPHOSPHATE; NANOPARTICLES; IMMUNOSENSOR; REDUCTION; DIAGNOSIS;
D O I
10.1021/acs.analchem.5b01858
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Traditionally, amplified DNA detection in a loop-mediated isothermal amplification (LAMP) was carried out in a complicated gel electrophoresis or with expensive fluorescence-based methods. Here, instead of direct detection that relies on amplified DNA, the indirect detection based on tracing phosphate ions (Pi) generated during LAMP by using an electrochemical method has been proposed for sensitive nucleic acid detection. Pyrophosphate (PPi) as the byproduct of nucleic acid polymerization reaction in LAMP was hydrolyzed into Pi by the preaddition of thermostable inorganic pyrophosphatase (PPase). Thus, the total amount of Pi in the LAMP-amplified sample was proportional to the amount of starting DNA templates. The obtained Pi could then react with acidic molybdate to form the molybdophosphate precipitates on the electrode surface, which serve as redox mediators to give a readily measurable electrochemical signal. The practicality of this strategy has been further demonstrated by employing it for sensitive and accurate quantification of Nosema bombycis genomic DNA PTP1. The electrochemical method allowed the quantitative analysis for target genomic DNA with a detection limit of 17 fg/mu L. Thus, we suppose that the novel method proposed in this work with superior sensitivity and specificity, as well as the simple feature, can be easily established for quantitative analysis of many other kinds of nucleic acids in the assistance of LAMP.
引用
收藏
页码:10268 / 10274
页数:7
相关论文
共 50 条
  • [31] Rapid and specific detection of Tilletia indica using loop-mediated isothermal DNA amplification
    Gao, Y.
    Tan, M. K.
    Zhu, Y. G.
    AUSTRALASIAN PLANT PATHOLOGY, 2016, 45 (04) : 361 - 367
  • [32] Detection of Group 1 Trypanosoma brucei gambiense by Loop-Mediated Isothermal Amplification
    Njiru, Z. K.
    Traub, R.
    Ouma, J. O.
    Enyaru, J. C.
    Matovu, E.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2011, 49 (04) : 1530 - 1536
  • [33] Loop-mediated isothermal amplification (LAMP) assays for rapid detection and differentiation of Nosema apis and N. ceranae in honeybees
    Ptaszynska, Aneta A.
    Borsuk, Grzegorz
    Wozniakowski, Grzegorz
    Gnat, Sebastian
    Malek, Wanda
    FEMS MICROBIOLOGY LETTERS, 2014, 357 (01) : 40 - 48
  • [34] Development of a loop-mediated isothermal amplification (LAMP) and a direct LAMP for the specific detection of Nosema ceranae, a parasite of honey bees
    Lucas Lannutti
    Anabela Mira
    Marina Basualdo
    Graciela Rodriguez
    Silvio Erler
    Victoria Silva
    Sebastian Gisder
    Elke Genersch
    Mónica Florin-Christensen
    Leonhard Schnittger
    Parasitology Research, 2020, 119 : 3947 - 3956
  • [35] Direct Detection of Equine Herpesvirus Type 1 DNA in Nasal Swabs by Loop-Mediated Isothermal Amplification (LAMP)
    Nemoto, Manabu
    Ohta, Minoru
    Tsujimura, Koji
    Bannai, Hiroshi
    Yamanaka, Takashi
    Kondo, Takashi
    Matsumura, Tomio
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2011, 73 (09): : 1225 - 1227
  • [36] Mitochondrial DNA Targets Increase Sensitivity of Malaria Detection Using Loop-Mediated Isothermal Amplification
    Polley, Spencer D.
    Mori, Yasuyoshi
    Watson, Julie
    Perkins, Mark D.
    Gonzalez, Iveth J.
    Notomi, Tsugunori
    Chiodini, Peter L.
    Sutherland, Colin J.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2010, 48 (08) : 2866 - 2871
  • [37] Gold Nanoparticles Based Colorimetric Detection of Target DNA After Loop-mediated Isothermal Amplification
    Zhou Chao
    Mu Ying
    Yang Meng-chao
    Wu Qing-qing
    Xu Wei
    Zhang Ying
    Jin Wei
    Song Qi
    Wu Zhong-yu
    Jin Qin-han
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2013, 29 (03) : 424 - 428
  • [38] Adapting Enzyme-Free DNA Circuits to the Detection of Loop-Mediated Isothermal Amplification Reactions
    Li, Bingling
    Chen, Xi
    Ellington, Andrew D.
    ANALYTICAL CHEMISTRY, 2012, 84 (19) : 8371 - 8377
  • [39] Use of loop-mediated isothermal amplification of DNA for the rapid detection of Mycobacterium tuberculosis in clinical specimens
    Neonakis, I. K.
    Spandidos, D. A.
    Petinaki, E.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2011, 30 (08) : 937 - 942
  • [40] The development of a loop-mediated isothermal amplification assay for rapid and sensitive detection of abalone herpesvirus DNA
    Chen, M. H.
    Kuo, S. T.
    Renault, T.
    Chang, P. H.
    JOURNAL OF VIROLOGICAL METHODS, 2014, 196 : 199 - 203