Clinical examination of proton pencil beam scanning on a moving anthropomorphic lung phantom

被引:13
|
作者
Wang, Peng [1 ]
Tang, Shikui [2 ]
Taylor, Paige A. [3 ]
Cummings, David E. [2 ]
Janson, Martin [4 ]
Traneus, Erik [4 ]
Sturgeon, Jared D. [2 ]
Lee, Andrew K. [2 ]
Chang, Chang [2 ]
机构
[1] Univ Maryland, Sch Med, Dept Radiat Oncol, 850 W Baltimore St, Baltimore, MD 21201 USA
[2] Texas Ctr Proton Therapy, Irving, TX USA
[3] Univ Texas MD Anderson Canc Ctr, Div Radiat Oncol, Dept Radiat Phys, Houston, TX 77030 USA
[4] RaySearch Labs, Stockholm, Sweden
关键词
Proton pencil beam lung treatment; Moving target interplay effect; Monte Carlo algorithm; EXPERIMENTAL-VERIFICATION; MOTION MITIGATION; BRAGG PEAK; THERAPY; RADIOTHERAPY; RANGE; QUANTIFICATION; UNCERTAINTIES; OPTIMIZATION;
D O I
10.1016/j.meddos.2018.04.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The objective of this study was to examine the use of proton pencil beam scanning for the treatment of moving lung tumors. A single-field uniform dose proton pencil beam scanning (PBS) plan was generated for the standard thorax phantom designed by the Imaging and Radiation Oncology Core (IROC) Houston QA Center. Robust optimization, including range and setup uncertainties as well as volumetric repainting, was used for the plan. Patient-specific quality assurance (QA) measurements were performed using both a water tank and a custom heterogeneous QA phantom. A custom moving phantom was used to find the optimal number of volumetric repainting. Both analytical and Monte Carlo (MC) algorithms were used for dose calculation and their accuracies were compared with actual measurements. A single ionization chamber, a 2-dimensional ionization chamber array, thermoluminescent dosimeters (TLDs), and films were used for dose measurements. The optimal number of volumetric repainting was found to be 4 times in our system. The mean dose overestimations on a moving target by analytical and MC algorithms based on a time-averaged computed tomography (CT) image of the phantom were found to be 4.8% and 2.4%, respectively. The mean gamma indexes for analytical and MC algorithms were 91% and 96%, respectively. The MC dose algorithm calculation was found to have a better agreement with measurements compared with the analytical algorithm. When treating moving lung tumors using proton PBS, the techniques of robust optimization, volumetric repainting, and MC dose calculation were found effective. Extra care needs to be taken when an analytical dose calculation algorithm is used. (C) 2018 American Association of Medical Dosimetrists. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:122 / 129
页数:8
相关论文
共 50 条
  • [1] Clinical Validation of Proton Pencil Beam Scanning on an Anthropomorphic Lung Phantom
    Wang, P.
    Tang, S.
    Cummings, D.
    Lee, A. K.
    Chang, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E736 - E736
  • [2] An anthropomorphic breathing phantom of the thorax for testing new motion mitigation techniques for pencil beam scanning proton therapy
    Perrin, R. L.
    Zakova, M.
    Peroni, M.
    Bernatowicz, K.
    Bikis, C.
    Knopf, A. K.
    Safai, S.
    Fernandez-Carmona, P.
    Tscharner, N.
    Weber, D. C.
    Parkel, T. C.
    Lomax, A. J.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (06): : 2486 - 2504
  • [3] A Comparison between Pencil Beam and Monte Carlo Algorithms Against Film Measurements in an Anthropomorphic Phantom for Proton Spot Scanning
    Saini, J.
    Maes, D.
    Bowen, S. R.
    Egan, A. J.
    Bloch, C.
    Wong, T. P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E717 - E718
  • [4] A breathing anthropomorphic phantom for experimental studies of moving tumors in scanning proton therapy
    Zakova, M.
    Schaetti, A.
    Knopf, A-C
    Safai, S.
    Meer, D.
    Zhang, Y.
    Lomax, T.
    Parkel, T.
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2013, 189 (12) : 1078 - 1078
  • [5] Quality assurance evaluation of spot scanning beam proton therapy with an anthropomorphic prostate phantom
    Iqbal, K.
    Gillin, M.
    Summers, P. A.
    Dhanesar, S.
    Gifford, K. A.
    Buzdar, S. A.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1031):
  • [6] Clinical Implementation of Pencil Beam Scanning (PBS) Proton Therapy
    Dong, Lei
    Dong, L.
    Zhu, X.
    Pankuch, M.
    Dong, L.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 3031 - 3032
  • [7] Quantification of the Interplay Effect in Proton Pencil Beam Scanning Treatment of Lung
    Kang, M.
    Huang, S.
    Solberg, T.
    Mayer, R.
    Thomas, A.
    Teo, B.
    McDonough, J.
    Simone, C., II
    Lin, L.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3887 - 3887
  • [8] Pencil Beam Scanning Proton Whole Lung Irradiation for Pediatric Patients
    Flampouri, S.
    Janopaul-Naylor, J.
    Slopsema, R.
    Esiashvili, N.
    Eaton, B. R.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2021, 111 (03): : E522 - E523
  • [9] Clinical Outcome of Pencil Beam Scanning Proton Therapy for Children With Rhabdomyosarcoma
    Leiser, D.
    Malyapa, R. S.
    Albertini, F.
    Kliebsch, U.
    Mikroutsikos, L.
    Morach, P.
    Bojaxhiu, B.
    Bolsi, A.
    Walser, M.
    Timmermann, B.
    Lomax, A. J.
    Schneider, R.
    Weber, D. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E547 - E548
  • [10] Adaptation of a Clinical Proton Pencil Beam Scanning System for FLASH Experiments
    Erickson, D. P. J.
    Saini, J.
    Cao, N.
    Ford, E. C.
    Emery, R.
    Kranz, M.
    Goff, P. H.
    Meyer, J.
    Wong, T.
    Bloch, C.
    Stewart, R. D.
    Sandison, G. A.
    Morimoto, A.
    DeLonais-Dick, A.
    Shaver, B.
    Rengan, R.
    Zeng, J.
    Schwarz, M.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E664 - E664