The Diagnostic Accuracy of Critical Care Pain Observation Tool (CPOT) in ICU Patients: A Systematic Review and Meta-Analysis

被引:18
|
作者
Zhai, Yue [1 ]
Cai, Shining [2 ]
Zhang, Yuxia [1 ,2 ]
机构
[1] Fudan Univ, Sch Nursing, Shanghai, Peoples R China
[2] Fudan Univ, Zhongshan Hosp, Dept Nursing, 180 Fenglin Rd, Shanghai 200032, Peoples R China
关键词
Critical pain observation tool; CPOT; behavioral pain scale; pain assessment; diagnostic studies; systematic review; VISUAL ANALOG SCALE; ILL ADULT PATIENTS; NOCICEPTIVE STIMULATION; PSYCHOMETRIC PROPERTIES; RATING-SCALE; VALIDATION; VERSION; INTENSITY; MANAGEMENT; MODERATE;
D O I
10.1016/j.jpainsymman.2020.06.006
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background. The critical care pain observation tool (CPOT) has been widely used to assess pain in ICU patients, and its validity and reliability have been tested in various contexts. Objective. To determine the diagnostic accuracy of the CPOT in critically ill patients, a systematic review of diagnostic studies was performed. Methods. A database search (PubMed, Medline, CINAHL, ProQuest, EMBASE, Cochrane Library, CNKI, Wanfang, COVIP, CBM) was conducted, as was the manual identification of eligible papers from citations. Eligible studies were published between 2006 and February 2020. Quality appraisal of the studies was carried out with the QUADAS-2 checklist, and data extraction was performed in alignment with STARD 2015. Open Meta Analyst was used for the statistical analysis. Results. In total, 25 articles involving 1920 subjects with 3493 experimental results were included. Most of the studies were of fair quality. A high degree of heterogeneity (1 2 = 57.2%, P < 0.001) was discovered. The Youden index values were 1.56 and 1.55 when the CPOT threshold was set at two and three, respectively. The diagnostic performance of the CPOT was affected by the reference standard. The CPOT had a higher diagnostic odds ratio of 11.52 (95% CI: 7.42-17.87) during nociceptive procedures compared with 9.14 (95% CI: 5.38-15.53) at rest or during non-nociceptive procedures. Conclusion. CPOT has moderate diagnostic parameters with a threshold of two or three, suggesting that it is a fair but not excellent tool. More research on the validity of the CPOT in specific subgroups is needed to broaden its applicability in critical care. (C) 2020 American Academy of Hospice and Palliative Medicine. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:847 / +
页数:23
相关论文
共 50 条
  • [31] Diagnostic accuracy of depression questionnaires in adult patients with diabetes: A systematic review and meta-analysis
    de Joode, Johanna W.
    van Dijk, Susan E. M.
    Walburg, Florine S.
    Bosmans, Judith E.
    van Marwijk, Harm W. J.
    de Boer, Michiel R.
    van Tulder, Maurits W.
    Adriaanse, Marcel C.
    PLOS ONE, 2019, 14 (06):
  • [32] Accuracy of Diagnostic Ultrasound in Patients With Suspected Subacromial Disorders: A Systematic Review and Meta-Analysis
    Ottenheijm, Ramon P.
    Jansen, Mariette J.
    Staal, J. Bart
    van den Bruel, Ann
    Weijers, Rene E.
    de Bie, Rob A.
    Dinant, Geert-Jan
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2010, 91 (10): : 1616 - 1625
  • [33] Comment on "Systematic Review and Meta-Analysis of Diagnostic Accuracy of miRNAs in Patients with Pancreatic Cancer"
    Jayaraj, Rama
    Kumarasamy, Chellan
    Madhav, Madurantakam Royam
    Pandey, Venkatesh
    Sabarimurugan, Shanthi
    Ramesh, N.
    Gothandam, K. M.
    Baxi, Siddhartha
    DISEASE MARKERS, 2018, 2018
  • [34] Implementation of the Critical Care Pain Observation Tool increases the frequency of pain assessment for noncommunicative ICU patients
    Phillips, Margaret Louise
    Kuruvilla, Vijo
    Bailey, Michael
    AUSTRALIAN CRITICAL CARE, 2019, 32 (05) : 367 - 372
  • [35] Accuracy of diagnostic tests for acute diverticulitis that are feasible in primary care: a systematic review and meta-analysis
    Vijfschagt, Natasja D.
    de Boer, Michiel R.
    Berger, Marjolein Y.
    Burger, Huibert
    Holtman, Gea A.
    FAMILY PRACTICE, 2024, 41 (01) : 1 - 8
  • [36] Diagnostic accuracy of point-of-care ultrasonography for intussusception in children: A systematic review and meta-analysis
    Lin-Martore, Margaret
    Firnberg, Maytal T.
    Kohn, Michael A.
    Kornblith, Aaron E.
    Gottlieb, Michael
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 58 : 255 - 264
  • [37] Diagnostic Accuracy of Point of Care Tests for Diagnosing Celiac Disease A Systematic Review and Meta-Analysis
    Singh, Prashant
    Arora, Ananya
    Strand, Tor A.
    Leffler, Daniel A.
    Maki, Markku
    Kelly, Ciaran P.
    Ahuja, Vineet
    Makharia, Govind K.
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2019, 53 (07) : 535 - 542
  • [38] DIAGNOSTIC ACCURACY OF POINT OF CARE TESTS FOR DIAGNOSING CELIAC DISEASE: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Singh, Prashant
    Arora, Ananya
    Strand, Tor A.
    Leffler, Daniel A.
    Maki, Markku
    Kelly, Ciaran P.
    Ahuja, Vineet
    Makharia, Govind K.
    GASTROENTEROLOGY, 2018, 154 (06) : S674 - S674
  • [39] Assessing Pain Behaviors in Healthy Subjects Using the Critical-Care Pain Observation Tool (CPOT): A Pilot Study
    Tousignant-Laflamme, Yannick
    Bourgault, Patricia
    Gelinas, Celine
    Marchand, Serge
    JOURNAL OF PAIN, 2010, 11 (10): : 983 - 987
  • [40] The diagnostic accuracy of the natriuretic peptides in heart failure: systematic review and diagnostic meta-analysis in the acute care setting
    Roberts, Emmert
    Ludman, Andrew J.
    Dworzynski, Katharina
    Al-Mohammad, Abdallah
    Cowie, Martin R.
    McMurray, John J. V.
    Mant, Jonathan
    BMJ-BRITISH MEDICAL JOURNAL, 2015, 350