Prototype 29 m long loop-tube-type thermoacoustic prime mover

被引:3
|
作者
Sakamoto, Shin-ichi [1 ]
Inui, Kenshiro [1 ]
Orino, Yuichiro [1 ]
Ueno, So [1 ]
机构
[1] Univ Shiga Prefecture, Dept Elect Syst Engn, Hikone, Shiga 5228533, Japan
关键词
COOLING SYSTEM; ENGINE; FREQUENCY; DESIGN;
D O I
10.35848/1347-4065/ab7e3d
中图分类号
O59 [应用物理学];
学科分类号
摘要
We report the performance of a prototype 29 m long loop-tube-type thermoacoustic prime mover. The phase adjuster (PA) that succeeded in low-temperature oscillation was examined for the aforementioned prototype. The onset temperature when PA length and PA position were changed was calculated using stability analysis. The onset temperature was found to be 153 degrees C. Using the calculation results, a prototype that succeeded in oscillating at an onset temperature of 155 degrees C was developed. These results indicate that the thermoacoustic system was successfully enlarged. This will promote practical application of a large system that converts waste heat to effective energy. (C) 2020 The Japan Society of Applied Physics
引用
收藏
页数:4
相关论文
共 27 条
  • [21] Low temperature difference thermoacoustic prime mover with asymmetric multi-stage loop configuration
    Jin, T.
    Yang, R.
    Wang, Y.
    Feng, Y.
    Tang, K.
    SCIENTIFIC REPORTS, 2017, 7
  • [22] Experimental and simulation studies on the performance of standing wave thermoacoustic prime mover for pulse tube refrigerator
    Kamble, Bharatbhushan V.
    Kuzhiveli, Biju T.
    Kasthurirengan, S.
    Behera, Upendra
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (08): : 2410 - 2419
  • [23] Effect of expanded part length on quality value in straight-tube-type thermoacoustic system with a diameter-expanded prime mover
    Egawa, Kohei
    Sakamoto, Shin-ichi
    Orino, Yuichiro
    Yamaga, Yuya
    Inui, Kenshiro
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2018, 57 (07)
  • [24] One factor of resonant wavelength shift from one-wavelength to two-wavelength resonance in loop-tube-type thermoacoustic cooling system
    Sakamoto, Shin-ichi
    Shibata, Kenji
    Kitadani, Yuji
    Inui, Yoshitaka
    Watanabe, Yoshiaki
    INTERNATIONAL CONGRESS ON ULTRASONICS (GDANSK 2011), 2012, 1433 : 628 - 631
  • [26] CONSTRUCTION AND PERFORMANCE OF A 2.7-M LONG STRAW DRIFT TUBE PROTOTYPE CHAMBER FOR THE SSC
    OH, SH
    GOSHAW, AT
    ROBERTSON, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 309 (03): : 368 - 376
  • [27] Controlling of loop-tube type thermoacoustic system using heat phase adjuster examination of the control mechanism using a physical model of the heat phase adjuster
    Shiraki, Kazuki
    Sakamoto, Shin-ichi
    Kurata, Yuya
    Kawashima, Yuto
    Onishi, Riku
    Watanabe, Yoshiaki
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2020, 59 (59)