Contrast Dose, Temporal Footprint, and Spatial Resolution Tradeoffs in Dynamic Contrast-Enhanced MRA Performed in a Porcine Model of a Carotid Aneurysm

被引:4
|
作者
Ai, Tao [1 ]
Goerner, Frank [2 ]
Patel, Nirav [2 ]
Trelles, Miguel [2 ]
Wu, Gang [1 ]
Li, Xiaoming [1 ]
Runge, Val M. [2 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Radiol, Wuhan 430030, Peoples R China
[2] Univ Texas Med Branch, Dept Radiol, Galveston, TX 77555 USA
关键词
brain; aneurysm; time-resolved; contrast-enhanced MRA; MAGNETIC-RESONANCE ANGIOGRAPHY; 3; T; ARTERIES;
D O I
10.1097/RCT.0b013e318276fc92
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the tradeoffs between temporal and spatial resolution and contrast dosing in dynamic contrast-enhanced magnetic resonance angiography (CE-MRA). Methods: Bilateral carotid artery aneurysms were created in a swine model. Dynamic CE-MRA using 1 mol/L gadobutrol was performed at 3 T, with high temporal (high-temp), middle temporal (mid-temp), and low temporal (low-temp) resolutions. High temporal CE-MRA was performed twice using 1 mL and 2 mL gadobutrol (2 mL/s). Middle temporal and low-temp sequences were performed once with 2 mL gadobutrol (2 mL/s). The signal-to-noise ratio (SNR) was quantitatively assessed. Blinded reads were used to qualitatively evaluate contrast dose and image quality. Results: The mean SNRs of high-temp, mid-temp, and low-temp resolutions were 56.7, 47.5, and 48.1. There was no significant difference between the 3 sequences with 2 mL gadobutrol. The mean SNR of the high-temp resolution with 2 mL was significantly higher than that with 1 mL (56.7 vs 39.9). In qualitative analysis, the 3 temporal sequences with 2 mL gadobutrol showed no significant differences regarding overall image quality and diagnostic value. High temporal resolution with 2 mL consistently showed the superiority of image quality than that with 1 mL. Conclusions: High temporal dynamic CE-MRA with 2mL (0.04 mmol/kg body weight) gadobutrol can produce consistently superior image quality over that with 1 mL (0.02 mmol/kg body weight). For a given contrast dose, the tradeoffs between temporal and spatial resolution will not result in significant differences in image quality in TWIST (time-resolved angiography with interleaved stochastic trajectories).
引用
收藏
页码:105 / 110
页数:6
相关论文
共 50 条
  • [21] MRA of intracranial aneurysm models: A comparison of contrast-enhanced three-dimensional MRA with time-of-flight MRA
    Isoda, H
    Takehara, Y
    Isogai, S
    Masunaga, H
    Takeda, H
    Nozaki, A
    Sakahara, H
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (02) : 308 - 315
  • [22] Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA
    Krishnam, M. S.
    Tomasian, A.
    Lohan, D. G.
    Tran, L.
    Finn, J. P.
    Ruehm, S. G.
    CLINICAL RADIOLOGY, 2008, 63 (07) : 744 - 755
  • [23] Contrast-enhanced MRA of the carotid arteries at 0.5 Tesla:: comparison with selective digital angiography
    Barbier, C
    Lefèvre, F
    Bui, P
    Denny, P
    Aiouaz, C
    Becker, S
    JOURNAL DE RADIOLOGIE, 2001, 82 (03): : 245 - 249
  • [24] Pulmonary vascular disease in infants and children: Evaluation with dynamic contrast-enhanced MRA
    Balci, NC
    Yalcin, Y
    Polat, B
    Duran, C
    RADIOLOGY, 2002, 225 : 529 - 529
  • [25] Dose-Dependent Artifact in the Far Wall of the Carotid Artery at Dynamic Contrast-enhanced US
    Thapar, Ankur
    Shalhoub, Joseph
    Averkiou, Michalakis
    Mannaris, Christophoros
    Davies, Alun H.
    Leen, Edward L. S.
    RADIOLOGY, 2012, 262 (02) : 672 - 679
  • [26] High Temporal Resolution Dynamic Contrast-Enhanced MRI at 7 Tesla: A Feasibility Study with Mouse Liver Model
    Hartono, S.
    Thng, C. H.
    Ng, Q. S.
    Yong, C. X.
    Yang, C. -T.
    Shi, W.
    Chuang, K. H.
    Koh, T. S.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 2788 - 2791
  • [27] Automated quantification of carotid artery stenosis on contrast-enhanced MRA data using a deformable vascular tube model
    Suinesiaputra, Avan
    de Koning, Patrick J. H.
    Zudilova-Seinstra, Elena
    Reiber, Johan H. C.
    van der Geest, Rob J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (06): : 1513 - 1524
  • [28] Automated quantification of carotid artery stenosis on contrast-enhanced MRA data using a deformable vascular tube model
    Avan Suinesiaputra
    Patrick J. H. de Koning
    Elena Zudilova-Seinstra
    Johan H. C. Reiber
    Rob J. van der Geest
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1513 - 1524
  • [29] Effect of Temporal Resolution on Diagnostic Performance of Dynamic Contrast-Enhanced Magnetic Resonance Imaging of the Prostate
    Othman, Ahmed E.
    Falkner, Florian
    Weiss, Jakob
    Kruck, Stephan
    Grimm, Robert
    Martirosian, Petros
    Nikolaou, Konstantin
    Notohamiprodjo, Mike
    INVESTIGATIVE RADIOLOGY, 2016, 51 (05) : 290 - 296
  • [30] An improved coverage and spatial resolution-using dual injection dynamic contrast-enhanced (ICE-DICE) MRI: A novel dynamic contrast-enhanced technique for cerebral tumors
    Li, Ka-Loh
    Buonaccorsi, Giovanni
    Thompson, Gerard
    Cain, John R.
    Watkins, Amy
    Russell, David
    Qureshi, Salman
    Evans, D. Gareth
    Lloyd, Simon K.
    Zhu, Xiaoping
    Jackson, Alan
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (02) : 452 - 462