MICROWAVE RADIOMETRY FOR CONTINUOUS NON-CONTACT TEMPERATURE MEASUREMENTS DURING MICROWAVE HEATING

被引:0
|
作者
Stephan, Karl D. [1 ]
Pearce, John A. [2 ]
机构
[1] Texas State Univ San Marcos, Dept Engn & Technol, San Marcos, TX 78666 USA
[2] Univ Texas Austin, Dept Elect & Comp Engn, Austin, TX 78712 USA
关键词
Radiometry; Temperature measurement;
D O I
暂无
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Temperature measurement during microwave heating in industrial and commercial processes can improve quality, throughput, and energy conservation. Conventional ways of measuring temperature inside a microwave oven cavity are costly, inconvenient, or unsuitable for high-volume industrial applications. In this paper, we describe the theory of microwave radiometry as applied to the measurement of temperature during microwave heating. By extending the theory of radiative transfer to the case of thermal microwave radiation inside a cavity, we show that the same characteristics which make a microwave cavity suitable for heating materials also assist in obtaining meaningful temperature data with microwave radiometry. We present experimental data from the heating of liquid and solid materials which confirm the essential features of the theory, and show agreement between this method and more conventional methods of +/- 4 C.
引用
收藏
页码:49 / 61
页数:13
相关论文
共 50 条
  • [21] Non-contact method for measurement of the microwave conductivity of graphene
    Hao, L.
    Gallop, J.
    Goniszewski, S.
    Shaforost, O.
    Klein, N.
    Yakimova, R.
    APPLIED PHYSICS LETTERS, 2013, 103 (12)
  • [22] Ensuring uniformity of measurements in microwave radiometry
    Yurchuk, E. F.
    Arsaev, I. E.
    MEASUREMENT TECHNIQUES, 2009, 52 (01) : 81 - 88
  • [23] Microwave processing of thermosets: non-contact cure monitoring and fibre optic temperature sensors
    Degamber, B
    Fernando, GF
    PLASTICS RUBBER AND COMPOSITES, 2003, 32 (8-9) : 327 - 333
  • [24] Ensuring the accuracy of non-contact temperature measurements
    Rols, Joris
    Electronics World, 2022, 127 (2013): : 22 - 23
  • [25] Effect of experimental parameters on temperature distribution during continuous and pulsed microwave heating
    Gunasekaran, Sundaram
    Yang, Huai-Wen
    JOURNAL OF FOOD ENGINEERING, 2007, 78 (04) : 1452 - 1456
  • [26] PRECISION TEMPERATURE REFERENCE FOR MICROWAVE RADIOMETRY
    HARDY, WN
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1973, MT21 (03) : 149 - 150
  • [27] Temperature Measurement by Microwave Radiometry.
    Cresson, P. -Y.
    Ricard, C.
    Dubois, L.
    Vaucher, S.
    Lasri, T.
    Pribetich, J.
    2008 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-5, 2008, : 1344 - +
  • [28] Feasibility of Blood Oxygen Saturation Levels using Non-contact Microwave Measurements at 60 GHz
    Quang Nguyen
    Fathy, Cherie A.
    Kilic, Ozlem
    Fathy, Aly E.
    2015 USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM) PROCEEDINGS, 2015, : 317 - 317
  • [29] Core temperature measurement by microwave radiometry
    Moran, DS
    Eliyahu, U
    Heled, Y
    Rabinovitz, S
    Hoffman, J
    Margaliot, M
    JOURNAL OF THERMAL BIOLOGY, 2004, 29 (7-8) : 539 - 542
  • [30] Non-contact active microwave sensor for glucose concentration measurement
    Suwanna, K.
    Harnsoongnoen, S.
    SIAM PHYSICS CONGRESS 2019 (SPC2019): PHYSICS BEYOND DISRUPTION SOCIETY, 2019, 1380