Reliability and validity of the Grip-Ball dynamometer for grip-strength measurement

被引:0
|
作者
Chkeir, Aly [1 ]
Jaber, Rana [1 ]
Hewson, David J. [1 ]
Duchene, Jacques [1 ]
机构
[1] Univ Technol Troyes, Troyes, France
关键词
OLDER WOMEN; FRAILTY; DISABILITY; COMMUNITY; MARKER; ADULTS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Grip-strength measurement is a key element in the evaluation of numerous conditions including frailty. An innovative grip-strength evaluation tool, the Grip-Ball has been developed for remote assessment of grip-strength. The Grip-Ball is an airtight ball that can be inflated to different pressures, thus varying the stiffness of the ball and the grip-strength dynamics. Three different initial pressures of 100, 125, and 150 kPa were evaluated in respect to reliability and validity, when compared to the Jamar. Reliability was very high, with ICC values of 0.95, 0.98, and 0.99 for 100, 125, and 150 kPa, respectively. The new device was highly correlated with the force measured using the Jamar for all initial pressures (r= 0.88, 0.93, and 0.93 for 100, 125, and 150 kPa, respectively). The possibility of varying the initial pressure would enable the Grip-Ball to be used for standard grip-strength testing and rehabilitation, while still maintaining high reliability and validity.
引用
收藏
页码:1996 / 1999
页数:4
相关论文
共 50 条
  • [31] MEASUREMENT OF GRIP STRENGTH - REPLY
    ROBERTSON, JC
    CLINICAL BIOMECHANICS, 1992, 7 (03) : 188 - 189
  • [32] Grip-strength, fatigue, and motor perseveration in anxious men without depression
    Everhart, DE
    Harrison, DW
    Shenal, BV
    Williamson, J
    Wuensch, KL
    NEUROPSYCHIATRY NEUROPSYCHOLOGY AND BEHAVIORAL NEUROLOGY, 2002, 15 (02): : 133 - 142
  • [33] Validity, reliability and test-retest study of Grip strength measurement in two positions with two dynamometers: Jamar® Plus and K-Force® Grip
    Uysal, Cildan
    Tonak, H. A.
    Kitis, A.
    HAND SURGERY & REHABILITATION, 2022, 41 (03): : 305 - 310
  • [34] Visual Feedback and Weight Reduction of a Grip Strength Dynamometer Do Not Increase Reliability in Healthy Children
    Molenaar, H. M.
    de Kraker, Marjolein
    Zuidam, J. Michiel
    Hovius, Steven E. R.
    Stam, Henk J.
    Selles, Ruud W.
    JOURNAL OF HAND THERAPY, 2010, 23 (03) : 272 - 279
  • [35] GRIP STRENGTH AND HAND POSITION OF THE DYNAMOMETER IN 204 FINNISH ADULTS
    HARKONEN, R
    PIIRTOMAA, M
    ALARANTA, H
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1993, 18B (01): : 129 - 132
  • [36] COMPARISON OF STOELTING HAND GRIP DYNAMOMETER AND LINEAR VOLTAGE DIFFERENTIAL TRANSFORMER FOR MEASURING MAXIMAL GRIP STRENGTH
    HEYWARD, V
    MCKEOWN, B
    GEESEMAN, R
    RESEARCH QUARTERLY, 1975, 46 (02): : 262 - 266
  • [37] EFFECT OF VARIATIONS IN HAND GRIP ON RECORDED DYNAMOMETER BACK STRENGTH
    HINOJOSA, R
    BERGER, RA
    RESEARCH QUARTERLY, 1965, 36 (03): : 366 - 367
  • [38] TIME COURSE OF FATIGUE IN GRIP-STRENGTH OF HEALTHY ADULTS WITH VARIABLE COOLING OF FOREARM
    UEDA, G
    BEPPU, H
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 1975, 19 (01) : 83 - 83
  • [39] Normal digital contribution to grip strength assessed by a computerized digital dynamometer
    Talsania, JS
    Kozin, SH
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (02): : 162 - 166
  • [40] Intra- and inter-instrument reliability of Grip-Strength Measurements: GripTrack (TM) and Jamar (R) hand dynamometers
    Svens, Birgit
    Lee, Hoe
    HAND THERAPY, 2005, 10 (02) : 47 - 55