Absorption measurements using low coherence interferometry

被引:0
|
作者
Storen, T [1 ]
Östling, D [1 ]
Svaasand, LO [1 ]
Lokberg, OJ [1 ]
Lindmo, T [1 ]
机构
[1] NTNU, Dept Phys, N-7034 Trondheim, Norway
关键词
low coherence interferometry; white-light; reflectometry; absorption; oximetry;
D O I
10.1117/12.339178
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The basic use of Low Coherence Interferometry is measuring the intensity of light reflected from defined depths in a partially transparent object. The light back-scattered from a certain depth in the object carries information about the medium that it has passed through. Absorption and scattering attenuate the intensity of the light, and will thus reduce the interference signal from a given depth. One single interference measurement will not discriminate between attenuation due to absorption and scattering. However, by measuring the interference signal at several different wavelengths, discrimination between the two parameters is possible, if they vary differently with wavelength. Especially when measurements are performed in a wavelength region where the scattering coefficient is constant, measurements at two different wavelengths will give the difference in absorption at the two wavelengths. We present preliminary measurements on scattering and absorbing solutions showing a qualitative difference in absorption measured at 810 and 830 nm. As an absorbing solution we used a commercially available dye with an absorption maximum at 800 nm while intralipid was used to introduce scattering. The aim of our work is to measure the oxygenation saturation of blood through absorption measurements at different wavelengths using Low Coherence Interferometry.
引用
收藏
页码:130 / 138
页数:9
相关论文
共 50 条
  • [1] Nuclear morphology measurements using Fourier domain low coherence interferometry
    Graf, RN
    Wax, A
    OPTICS EXPRESS, 2005, 13 (12): : 4693 - 4698
  • [2] Nuclear morphology measurements using Fourier domain low coherence interferometry
    Graf, RN
    Wax, A
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 460 - 467
  • [3] Measurements of velocity distribution along depth using low coherence interferometry
    Imai, Y
    Tanaka, K
    Higo, H
    OPTICAL ENGINEERING, 2000, 39 (04) : 947 - 951
  • [4] PMD MEASUREMENTS BASED ON LOW-COHERENCE INTERFEROMETRY USING A MICHELSON INTERFEROMETER
    Amaral, Luis M. N.
    Pereira, D. A.
    Frazao, O.
    Marques, M. B.
    Lima, M. J. N.
    Teixeira, A. L. J.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2010, 52 (10) : 2310 - 2312
  • [5] Rapid angle-resolved low coherence interferometry measurements
    Pyhtila, JW
    Wax, A
    Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX, 2005, 5690 : 468 - 474
  • [6] Phase Tandem Low-Coherence Interferometry for Surface Vibration Measurements
    Volkov, Petr
    Bobrov, Alexander
    Goryunov, Alexander
    Kovrigin, Mark
    Lukyanov, Andrey
    Semikov, Daniil
    Vyazankin, Oleg
    SENSORS, 2025, 25 (03)
  • [7] Quantification of skin wrinkles using low coherence interferometry
    Oh, JT
    Kim, BM
    Son, SR
    Lee, SW
    Kim, DY
    Kim, YS
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 463 - 466
  • [8] Fiber optic sensing using low coherence interferometry
    Sorin, WV
    SECOND PACIFIC NORTHWEST FIBER OPTIC SENSOR WORKSHOP, 1996, 2872 : 40 - 47
  • [9] ABSOLUTE OPTICAL RANGING USING LOW COHERENCE INTERFEROMETRY
    DANIELSON, BL
    BOISROBERT, CY
    APPLIED OPTICS, 1991, 30 (21): : 2975 - 2979
  • [10] Measurements of absorption and dispersion properties with a 2-D tomographic image by use of spectral domain low coherence interferometry
    Fujioka, R
    Suekuni, M
    Suzuki, K
    Teramura, Y
    Kannari, F
    CLEO(R)/PACIFIC RIM 2001, VOL II, TECHNICAL DIGEST, 2001, : 272 - 273