Three-dimensional cellular-level imaging using full-field optical coherence tomography

被引:108
|
作者
Dubois, A [1 ]
Moneron, G [1 ]
Grieve, K [1 ]
Boccara, AC [1 ]
机构
[1] CNRS, UPR A0005, Lab Opt Phys, Ecole Super Phys & Chim Ind, F-75231 Paris 5, France
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 07期
关键词
D O I
10.1088/0031-9155/49/7/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An ultrahigh-resolution full-field optical coherence tomography (OCT) system has been developed for cellular-level imaging of biological media. The system is based on a Linnik interference microscope illuminated with a tungsten halogen lamp, associated with a high-resolution CCD camera. En face tomographic images are produced in real time, with the best spatial resolution ever achieved in OCT (0.7 mum x 0.9 mum, axial x transverse). A shot-noise limited detection sensitivity of 80 dB can be reached with an acquisition time per image of 1 s. Images of animal ophthalmic biopsies and vegetal tissues are shown.
引用
收藏
页码:1227 / 1234
页数:8
相关论文
共 50 条
  • [31] Full-field optical coherence tomography with thermal light
    Laude, B
    De Martino, A
    Drévillon, B
    Benattar, L
    Schwartz, L
    APPLIED OPTICS, 2002, 41 (31) : 6637 - 6645
  • [32] Dark-field full-field optical coherence tomography
    Auksorius, Egidijus
    Boccara, A. Claude
    OPTICS LETTERS, 2015, 40 (14) : 3272 - 3275
  • [33] Spectroscopic Full-field Optical Coherence Tomography in Dermatology
    Soundararajan, Rajendran
    Hsu, Ting-Wei
    Calderon-Delgado, Manuel
    Donati, Silvano
    Qin, Yanding
    Huang, Sheng-Lung
    2019 IEEE INTERNATIONAL CONFERENCE ON BIOPHOTONICS (BIOPHOTONICS), 2019,
  • [34] Appearance of the Retina With Full-Field Optical Coherence Tomography
    Grieve, Kate
    Thouvenin, Olivier
    Sengupta, Abhishek
    Borderie, Vincent M.
    Paques, Michel
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (09) : OCT96 - OCT104
  • [35] Development of full-field optical coherence tomography system
    Yang Ya-Liang
    Ding Zhi-Hua
    Wang Kai
    Wu Ling
    Wu Lan
    ACTA PHYSICA SINICA, 2009, 58 (03) : 1773 - 1778
  • [36] Full-field optical coherence tomography using tunable-path-difference source for three-dimensional multi-layered imaging with enhanced signal-to-noise ratio
    Kim, Jaeheung
    Park, Sang Min
    Kim, Gyeong Hun
    Park, Minyoung
    Kim, Jeesu
    Kim, Chang-Seok
    OPTICS AND LASERS IN ENGINEERING, 2021, 147
  • [37] Three-Dimensional Imaging of Bladder Cancer Using Optical Coherence Tomography and Fluorescence Laminar Optical Tomography
    Yan, Feng
    Madka, Venkateshwar
    Wang, Chen
    Valerio, Trisha, I
    Watson, Maegan M.
    Wilson, Jayla A.
    Rao, Chinthalapally, V
    Tang, Qinggong
    MULTIMODAL BIOMEDICAL IMAGING XVI, 2021, 11634
  • [38] Three-dimensional endomicroscopy using optical coherence tomography
    Desmond C. Adler
    Yu Chen
    Robert Huber
    Joseph Schmitt
    James Connolly
    James G. Fujimoto
    Nature Photonics, 2007, 1 : 709 - 716
  • [39] Three-dimensional endomicroscopy using optical coherence tomography
    Adler, Desmond C.
    Chen, Yu
    Huber, Robert
    Schmitt, Joseph
    Connolly, James
    Fujimoto, James G.
    NATURE PHOTONICS, 2007, 1 (12) : 709 - 716
  • [40] Line-field confocal optical coherence tomography for three-dimensional skin imaging
    Jonas Ogien
    Anthony Daures
    Maxime Cazalas
    Jean-Luc Perrot
    Arnaud Dubois
    Frontiers of Optoelectronics, 2020, 13 : 381 - 392