BIPM comparison BIPM.RI(II)-K1.Am-241 of the activity measurements of the radionuclide 241Am

被引:1
|
作者
Ratel, G. [1 ]
Michotte, C. [1 ]
机构
[1] Bur Int Poids & Mesures, Pavillon Breteuil, F-92312 Sevres, France
关键词
D O I
10.1088/0026-1394/40/1A/06001
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Since 1977, six national metrology institutes (NMIs) have submitted ten samples of known activity of Am-241 to the International Reference System (SIR) for activity comparison at the Bureau International des Poids et Mesures. The activities ranged from about 3 MBq to 17 MBq. The degrees of equivalence between each equivalent activity measured in the SIR and the key comparison reference value (KCRV) have been calculated and the results are given in the form of a matrix for five NMIs. A graphical presentation is also given.
引用
收藏
页数:2
相关论文
共 50 条
  • [31] BIPM comparison BIPM.RI(II)-K1.Ru-103 of activity measurements of the radionuclide 103Ru
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2003, 40
  • [32] BIPM comparison BIPM.RI(II)-K1.Th-228 of activity measurements of the radionuclide 228Th
    Michotte, C.
    Ratel, G.
    Courte, S.
    Lucas, L.
    Kossert, K.
    Naehle, O.
    Ott, O.
    METROLOGIA, 2016, 53
  • [33] Activity measurements of the radionuclide 67Ga for the CIEMAT in the BIPM comparison BIPM.RI(II)K1.Ga-67
    Ratel, G.
    Michotte, C.
    Arcos, J. -M Los
    METROLOGIA, 2003, 40
  • [34] BIPM comparison BIPM.RI(II)-K1.Tc-99m of activity measurements of the radionuclide 99Tcm
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2004, 41
  • [35] Update of the BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18F to include the NPL
    Ratel, G.
    Michotte, C.
    Woods, M. J.
    METROLOGIA, 2003, 40
  • [36] Update of the BIPM comparison BIPM.RI(II)-K1.F-18 of activity measurements of the radionuclide 18F to include the CIEMAT
    Ratel, G.
    Michotte, C.
    Garcia-Torano, E.
    Los Arcos, J-M
    METROLOGIA, 2004, 41
  • [37] Activity measurements of the radionuclide 60Co for the CSIR-NML and the CNEA in the BIPM comparison BIPM.RI(II)-K1.Co-60
    Ratel, G.
    Michotte, C.
    Simpson, B. R. S.
    Lglicki, A.
    METROLOGIA, 2003, 40
  • [38] BIPM comparison BIPM.RI(II)-K1.Sc-47 of activity measurements of the radionuclide 47Sc and links for the 1983 EUROMET.RI(II)-K2.Sc-47 comparison
    Ratel, G.
    Michotte, C.
    Reher, D.
    METROLOGIA, 2004, 41
  • [39] BIPM comparison BIPM. RI(II)-K1.Sr-85 of activity measurements of the radionuclide 85Sr
    Ratel, G.
    Michotte, C.
    METROLOGIA, 2004, 41
  • [40] Activity measurements of the radionuclide 186Re for the PTB, Germany in the comparison BIPM.RI(II)-K1.Re-186
    Ratel, G.
    Michotte, C.
    Kryeziu, D.
    Kossert, K.
    METROLOGIA, 2008, 45