Features of the discharge ignition in the trigger unit of the cold-cathode thyratron

被引:1
|
作者
Landl, N. V. [1 ]
Korolev, Y. D. [1 ]
Geyman, V. G. [1 ]
Frants, O. B. [1 ]
Argunov, G. A. [1 ]
Bolotov, A. V. [1 ]
机构
[1] Inst High Current Elect SB RAS, Akad Ave 2-3, Tomsk 634055, Russia
基金
俄罗斯科学基金会;
关键词
OFF PSEUDOSPARK SWITCHES; VOLTAGE;
D O I
10.1088/1742-6596/1115/2/022031
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The sealed-off cold-cathode thyratron TPI1-10k/50 type with a newly developed trigger unit based on auxiliary glow discharge is investigated. As distinct from the commercially produced sealed-off thyratrons, in the thyratron under investigation the high-emissivity tablet is not used. Features of ignition of the trigger discharge are considered. It has been revealed that the delay time to breakdown in the trigger unit and a jitter in the delay time decrease with an increase in working gas pressure. The delay time can be significantly decreased due to availability of the so-called parasitic current in the electrode system of trigger unit. A capability of the thyratron operation with a stability in delay time no more than 4 ns is demonstrated.