Development and Experimental Verification of a Nonlinear Hyperelastic Model for Microneedle-skin Interactions

被引:0
|
作者
Chen, S. H. [1 ]
Li, N. N. [1 ]
Chen, J. [1 ]
机构
[1] Peking Univ, Natl Key Lab Micro Nano Fabricat Technol, Inst Microelect, Beijing 100871, Peoples R China
关键词
microneedles; finite element model; needle insertion force; experimental verification; drug delivery; TITANIUM MICRONEEDLES; MECHANICAL-BEHAVIOR; NEEDLE INSERTION; PREDICTION; SIMULATION; DELIVERY; FORCE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the years, microneedles with varieties of materials and shapes have been fabricated, however, simulation of the penetration of microneedle through the skin are seldom reported. This paper reports on modeling and verification of microneedle-skin interactions. For the first time, a nonlinear hyperelastic model on the micro scale for large deformation is developed to determine several phenomena during the inserting. The accuracy is experimentally verified by measuring the relationship between force and displacements during the insertion of mouse skin. To prove the breakage on the skin, the permeability is tested for diclofenac. The cumulative permeation with pierced skins is 10,000 times larger than untreated counterpart. The simulation results indicated that the maximum insertion force produced when microneedles array was inserted perpendicularly and insertion force increased strongly with the tip width. Based on this model, the design of microneedle can be optimized.
引用
收藏
页码:61 / 65
页数:5
相关论文
共 50 条
  • [21] STAPHYLOCOCCAL SCALDED-SKIN SYNDROME - DEVELOPMENT OF AN EXPERIMENTAL MODEL
    MELISH, ME
    GLASGOW, LA
    NEW ENGLAND JOURNAL OF MEDICINE, 1970, 282 (20): : 1114 - +
  • [22] Impact of nonlinear phase noise to DPSK signals: Experimental verification of a simplified theoretical model
    Huang, JA
    Ho, KP
    Chen, HK
    Liaw, SK
    Wang, HC
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (10) : 2236 - 2238
  • [23] Nonlinear Seismic Response Analysis Model and Experimental Verification for Pile Foundation of Bridge Structure
    Chen, Xingchong
    Wang, Changfeng
    Liu, Zunwen
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING II, PTS 1-4, 2013, 405-408 : 1993 - +
  • [24] Establishment and experimental verification of a theoretical model for axial nonlinear stiffness of bolt connected members
    Lu, Shikun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2025, : 1901 - 1913
  • [25] Nonlinear Model Establishment and Experimental Verification of a Pneumatic Rotary Actuator Position Servo System
    Zhang, Yeming
    Li, Ke
    Wang, Geng
    Liu, Jingcheng
    Cai, Maolin
    ENERGIES, 2019, 12 (06)
  • [26] Development and experimental verification of a prognosis model for disulfidptosis-associated genes in HNSCC
    Li, Yushen
    Tao, Lu
    Xin, Jiajun
    Dai, Yifei
    Chen, Xiantao
    Zou, Jiatong
    Wang, Rui
    Wang, Bowei
    Liu, Zhihui
    MEDICINE, 2024, 103 (12) : E37308
  • [27] Development and experimental verification of momentum, heat and mass transfer model in spray drying
    Zbicinski, I., 1600, Elsevier Science S.A., Lausanne, Switzerland (58):
  • [28] Model Development and Experimental Verification for Permeability Coefficient of Soil-Rock Mixture
    Zhou, Zhong
    Yang, Hao
    Wang, Xiangcan
    Liu, Baochen
    INTERNATIONAL JOURNAL OF GEOMECHANICS, 2017, 17 (04)
  • [29] Development and experimental verification of a genome-scale metabolic model for Corynebacterium glutamicum
    Shinfuku, Yohei
    Sorpitiporn, Natee
    Sono, Masahiro
    Furusawa, Chikara
    Hirasawa, Takashi
    Shimizu, Hiroshi
    MICROBIAL CELL FACTORIES, 2009, 8
  • [30] Development and experimental verification of a prognosis model for cuproptosis-related subtypes in HCC
    Wang, Yixiu
    Zhang, Yongfa
    Wang, Longrong
    Zhang, Ning
    Xu, Weiqi
    Zhou, Jiamin
    Zhao, Yiming
    Zhu, Weiping
    Zhang, Ti
    Wang, Lu
    HEPATOLOGY INTERNATIONAL, 2022, 16 (06) : 1435 - 1447