Effect of biaxial versus coaxial microincision cataract surgery on optical quality of the cornea

被引:8
|
作者
Eliwa, Tamer Fahmy [1 ]
Elsamkary, Mahmoud A. [1 ]
Hamza, Ismail [1 ]
机构
[1] Ain Shams Univ, Dept Ophthalmol, Cairo, Egypt
关键词
Cataract surgery; corneal aberrations; corneal astigmatism; high order aberrations; microincision cataract surgery; HIGH-ORDER ABERRATIONS; RETINAL IMAGE QUALITY; INTRAOCULAR LENSES; SMALL-INCISION; PHACOEMULSIFICATION; ASTIGMATISM;
D O I
10.4103/0301-4738.162598
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Visual function is determined by a combination of the cornea, which has a larger effect and internal aberrations generated by the intraocular lens and those induced by the surgery. These corneal refractive changes are related to the location and size of the corneal incision. The smaller the incision, the lower the aberrations and the better the optical quality. Aims: To compare the effect of uneventful coaxial versus biaxial microincision cataract surgery (MICS) on the corneal aberrations. Settings and Design: Retrospective interventional nonrandomized comparative case study comprised 40 eyes of 36 patients with primary senile cataract. Subjects and Methods: They were divided into two groups: Group I (20 eyes) had operated by biaxial MICS and Group II (20 eyes) had operated by coaxial MICS. Each group were assessed by corneal topography and wavefront analysis over 6 mm pupil size preoperatively and 1-month postoperatively. Statistical Analysis Used: Statistical analysis was performed using SPSS for Windows (version 17.0.1, SPSS, Inc.). The paired (-test was used to compare the mean values of corneal aberrations preoperatively and 1-month postoperatively in each group. Results: There was a significant increase in trefoil and quatrefoil in biaxial MICS (P = 0.063, 0.032 respectively) while other aberrations insignificantly changed. The coaxial MICS showed a significant increase in root mean square (RMS) of total high order aberrations (HOAs) (P = 0.02) and coma (0.028), but not the others. In comparison to each other, there was the insignificant difference as regards astigmatism, RMS of individual and total HOAs. Conclusions: Coaxial and biaxial MICS are neutral on corneal astigmatism and aberrations.
引用
收藏
页码:487 / 490
页数:4
相关论文
共 50 条
  • [21] Contrast sensitivity after implantation of a spherical versus an aspherical intraocular lens in biaxial microincision cataract surgery
    Kurz, Sabine
    Krummenauer, Frank
    Thieme, Hagen
    Dick, H. Burkhard
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03): : 393 - 400
  • [22] Uncorrected Visual Acuity One Hour Following Uncomplicated Cataract Surgery: Bimanual Microincision Cataract Surgery Versus Standard Coaxial Phacoemulsification
    Saeed, A.
    O'Connor, J.
    Cunnife, G.
    Mulhern, M.
    Beatty, S.
    [J]. IRISH JOURNAL OF MEDICAL SCIENCE, 2015, 184 : 461 - 461
  • [23] Effects of spherical aberration on objective optical quality after microincision cataract surgery
    Nochez, Y.
    Majzoub, S.
    Pisella, P. -J.
    [J]. JOURNAL FRANCAIS D OPHTALMOLOGIE, 2010, 33 (01): : 16 - 22
  • [24] Cross-action capsulorhexis forceps for coaxial microincision cataract surgery
    Ratnarajan, Gokulan
    Calladine, Daniel
    Watson, Sarah-Lucie
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (08): : 1559 - 1560
  • [25] Uncorrected visual acuity in the immediate postoperative period following uncomplicated cataract surgery: Bimanual microincision cataract surgery versus standard coaxial phacoemulsification
    Saeed A.
    O'Connor J.
    Cunnife G.
    Stack J.
    Mullhern M.G.
    Beatty S.
    [J]. International Ophthalmology, 2009, 29 (5) : 393 - 400
  • [26] Comparison of tips in coaxial microincision cataract surgery with the bevel-down technique
    Kim, Eun Kyoung
    Jo, Kyong Jin
    Joo, Choun-Ki
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (11): : 2028 - 2033
  • [27] Comparison of macular thickness and inflammatory cytokine levels after microincision versus small incision coaxial cataract surgery
    Hwang, Ho Sik
    Ahn, Ye Jin
    Lee, Hee Jin
    Kim, Man Soo
    Kim, Eun Chul
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (03) : E189 - E194
  • [28] Standard coaxial phaco vs microincision cataract surgery: a corneal endothelium study
    Franchini, Alessandro
    Frosini, Saverio
    Boddi, Vieri
    [J]. INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2008, 1 (04) : 344 - 350
  • [29] Clinical results after microincision biaxial cataract surgery and implantation of an Incise intraocular lens
    Wojciech Lubiński
    Marta Kirkiewicz
    Karolina Podborączyńska-Jodko
    [J]. International Ophthalmology, 2018, 38 : 1977 - 1983
  • [30] Clinical results after microincision biaxial cataract surgery and implantation of an Incise intraocular lens
    Lubinski, Wojciech
    Kirkiewicz, Marta
    Podboraczynska-Jodko, Karolina
    [J]. INTERNATIONAL OPHTHALMOLOGY, 2018, 38 (05) : 1977 - 1983