A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate

被引:38
|
作者
Wu, MH
Cai, HY
Xu, X
Urban, JPG
Cui, ZF
Cui, Z [1 ]
机构
[1] Rutherford Appleton Lab, Cent Microstruct Facil, Didcot, Oxon, England
[2] Univ Oxford, Univ Lab Physiol, Oxford OX1 2JD, England
[3] Chinese Acad Sci, Inst Elect, Beijing, Peoples R China
[4] Univ Oxford, Dept Engn Sci, Oxford OX1 2JD, England
基金
英国生物技术与生命科学研究理事会;
关键词
microfluidic device; SU-8; PDMS; optical fibre; online monitoring; lactate;
D O I
10.1007/s10544-005-6074-y
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The device consists of a SU-8 waveguide, microfluidic channels and grooves for the insertion of optic fibres. It was fabricated by one-step photolithography of SU-8 polymer resist. Different channel widths (50-300 mu m) were tested in terms of detection sensitivity. A wide range of flow rates were applied to investigate the influence of flow rate on signal fluctuations. The separation between optical fibre sensor and microfluidic channel and the width of fluidic channel have been optimized to maximize the detection sensitivity. It was revealed that 250 mu m of channel width is the optimum light path length for a compromise between detection sensitivity and interference of ambient light. The independence of detection signals on flow rates was demonstrated within the range of flow rate (0.5-5 ml/hr) tested. Compared with conventional lactate detection, the device is proved to have high accuracy, :relatively low limit of detection (50 mg/L) and reasonably fast response time (100 sec). The fabrication of device is simple and low cost. The present work has provided some fundamental data for further system optimization to meet specific detection requirements.
引用
收藏
页码:323 / 329
页数:7
相关论文
共 49 条
  • [21] A novel device of passive and fixed alignment of optical fiber using SU-8 photoresist
    Liu, JQ
    Cai, BC
    Zhu, J
    Chen, D
    Li, YG
    Zhang, JL
    Ding, GP
    Zhao, XL
    Yang, CS
    MEMS/MOEMS TECHNOLOGIES AND APPLICATIONS, 2002, 4928 : 1 - 5
  • [22] Enclosed SU-8 and PDMS microchannels with integrated interconnects for chip-to-chip and world-to-chip connections
    Westwood, S. M.
    Jaffer, S.
    Gray, B. L.
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2008, 18 (06)
  • [23] Characterization of SU-8 optical multimode waveguides for integrated optics and sensing on microchip devices
    Piruska, A.
    Bhagat, A. A. S.
    Zhou, K.
    Peterson, E. T. K.
    Papautsky, I.
    Seliskar, C. J.
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112
  • [24] Integrated optical Mach-Zehnder on SU-8 polymer for designing thermal sensors
    Pelletier, N
    Bêche, B
    Camberlein, L
    Gaviot, E
    Giordani, N
    Zyss, J
    PROCEEDINGS OF THE IEEE SENSORS 2004, VOLS 1-3, 2004, : 868 - 871
  • [25] Photo-hardenable and patternable PDMS/SU-8 hybrid functional material: A smart substrate for flexible systems
    Seghir, Rian
    Arscott, Steve
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2015, 53 (18) : 1281 - 1291
  • [26] Fabrication of asperical lensed optical fibers with an electro-static pulling of SU-8 photoresist
    Wu, Chun-Ching
    Tseng, Yi-Dun
    Kuo, Su-Ming
    Lin, Che-Hsin
    OPTICS EXPRESS, 2011, 19 (23): : 22993 - 22998
  • [27] SU-8 Polymer Enclosed Microchannels with Interconnect and Nanohole Arrays as an Optical Detection Device for Biospecies
    Westwood, S. M.
    Gray, B. L.
    Grist, S.
    Huffman, K.
    Jaffer, S.
    Kavanagh, K. L.
    2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 5652 - +
  • [28] Fabrication of a hybrid PDMS/SU-8/quartz microfluidic chip for enhancing UV absorption whole-channel imaging detection sensitivity and application for isoelectric focusing of proteins
    Ou, Junjie
    Glawdel, Tomasz
    Ren, Carolyn L.
    Pawliszyn, Janusz
    LAB ON A CHIP, 2009, 9 (13) : 1926 - 1932
  • [29] Preliminary investigations into SU-8 as a material for integrated all-optical microwave filters.
    Curtis, PD
    Iezekiel, S
    Miles, RE
    Pescod, CR
    2000 HIGH FREQUENCY POSTGRADUATE STUDENT COLLOQUIUM, 2000, : 116 - 120
  • [30] A PDMS microfluidic system with poly(ethylene glycol)/SU-8 based apertures for planar whole cell-patch-clamp recordings
    Xu, Baojian
    Liu, Zongbin
    Lee, Yi-Kuen
    Mak, Arthur
    Yang, Mo
    SENSORS AND ACTUATORS A-PHYSICAL, 2011, 166 (02) : 219 - 225