Regurgitation Quantification Using 3D PISA in Volume Echocardiography

被引:0
|
作者
Grady, Leo [1 ]
Datta, Saurabh [2 ]
Kutter, Oliver [1 ]
Duong, Christophe
Wein, Wolfgang [3 ]
Little, Stephen H. [4 ]
Igo, Stephen R. [4 ]
Liu, Shizhen [5 ]
Vanna, Mani [5 ]
机构
[1] Siemens Corp Res, Princeton, NJ USA
[2] Siemens Healthcare, Ultrasound Business Unit, Mountain View, CA USA
[3] White Lion Technol AG, Munich, Germany
[4] Methodist DeBakey Heart Vasc Ctr, Houston, TX USA
[5] Ohio State Univ, Columbus, OH USA
关键词
SEGMENTATION;
D O I
暂无
中图分类号
TP301 [理论、方法];
学科分类号
081202 ;
摘要
We present the first system for measurement of proximal isovelocity surface area (PISA) on a 3D ultrasound acquisition using modified ultrasound hardware, volumetric image segmentation and a simple efficient workflow. Accurate measurement of the PISA in 3D flow through a valve is an emerging method for quantitatively assessing cardiac valve regurgitation and function. Current state of the art protocols for assessing regurgitant flow require laborious and time consuming user interaction with the data, where a precise execution is crucial for an accurate diagnosis. We propose a new improved 3D PISA workflow that is initialized interactively with two points, followed by fully automatic segmentation of the valve annulus and isovelocity surface area computation. Our system is first validated against several in vitro phantoms to verify the calculations of surface area, orifice area and regurgitant flow. Finally, we use our system to compare orifice area calculations obtained from in vivo patient imaging measurements to an independent measurement and then use our system to successfully classify patients into mild-moderate regurgitation and moderate-severe regurgitation categories.
引用
收藏
页码:512 / +
页数:2
相关论文
共 50 条
  • [41] Quantification of mitral regurgitation during interventional valve repair: Correlation between haemodynamic parameters and 3D color Doppler echocardiography
    Goebel, B.
    Rohm, I.
    Hamadanchi, A. L. I.
    Otto, S.
    Jung, C.
    Figulla, H. R.
    Schulze, P. C.
    Poerner, T. C.
    EUROPEAN HEART JOURNAL, 2016, 37 : 464 - 464
  • [42] Morphological evaluation of a regurgitant orifice by 3-D echocardiography: Applications in the quantification of valvular regurgitation
    Anayiotos, AS
    Smith, BK
    Kolda, M
    Fan, PH
    Nanda, NC
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1999, 25 (02): : 209 - 223
  • [43] Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI
    Stoebe S.
    Metze M.
    Jurisch D.
    Tayal B.
    Solty K.
    Laufs U.
    Pfeiffer D.
    Hagendorff A.
    Echo Research & Practice, 2018, 5 (2): : 51 - 62
  • [44] Towards an Operator Independent Blood Flow Volume Quantification Using 3D Ultrasound
    Li, Sibo
    Shi, William
    Pinter, Stephen Z.
    Rubin, Jonathan M.
    Kripfgans, Oliver D.
    Fowlkes, J. Brian
    Leichner, Ronald D.
    Jago, James R.
    Sethuraman, Shriram
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [45] AUTOMATED QUANTITATIVE MODELING OF THE AORTIC VALVE AND ROOT IN AORTIC REGURGITATION USING VOLUME 3-D TRANSESOPHAGEAL ECHOCARDIOGRAPHY
    Calleja, Anna
    Razvan, Ionasec
    Houle, Helene
    Liu, Shizhen
    Dickerson, Jennifer
    Thavendiranathan, Paaladinesh
    Sai-Sudhakar, Chittoor
    Crestanello, Juan
    Ryan, Thomas
    Vannan, Mani
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [46] QUANTIFICATION OF MITRAL REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    ZHANG, Y
    IHLEN, H
    MYHRE, E
    LEVORSTAD, K
    NITTERHAUGE, S
    CIRCULATION, 1985, 72 (04) : 306 - 306
  • [47] QUANTIFICATION OF MITRAL REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    ZHANG, Y
    IHLEN, H
    MYHRE, E
    LEVORSTAD, K
    NITTERHAUGE, S
    EUROPEAN HEART JOURNAL, 1987, 8 : 59 - 62
  • [48] 3D echocardiography
    Flachskampf, FA
    ZEITSCHRIFT FUR KARDIOLOGIE, 2000, 89 : 104 - 109
  • [49] QUANTIFICATION OF VALVULAR REGURGITATION BY DOPPLER ECHOCARDIOGRAPHY
    SIMPSON, IA
    SAHN, DJ
    CIRCULATION, 1991, 84 (03) : I188 - I192
  • [50] Quantification of mitral valve regurgitation by 2D and 3D echocardiography compared with cardiac magnetic resonance a systematic review and meta-analysis
    Victor Sköldborg
    Per Lav Madsen
    Morten Dalsgaard
    Jawdat Abdulla
    The International Journal of Cardiovascular Imaging, 2020, 36 : 279 - 289