HIGHLY EFFICIENT DECOMPOSITION OF HFC-134a BY COMBUSTION OXIDIZATION METHOD

被引:0
|
作者
Qin, Linbo [1 ]
Han, Jun [1 ]
Liu, Long [1 ]
Yang, Xiulin [1 ]
Kim, Heejoon [2 ]
Yu, Fei [3 ]
机构
[1] Wuhan Univ Sci & Technol, Hubei Key Lab Coal Convers & New Mat, Wuhan 430081, Peoples R China
[2] Niigata Univ, Dept Chem & Chem Engn, Niigata 950218, Japan
[3] Mississippi State Univ, Dept Agr & Biol Engn, Mississippi State, MS 39762 USA
来源
FRESENIUS ENVIRONMENTAL BULLETIN | 2013年 / 22卷 / 07期
关键词
HFC-134a; Combustion oxidization; decomposition; Excess air ratio; HFC-134a/LPG; Premixed flame; Premixed-diffusive flame;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this paper, a low-cost combustion system was developed to effectively destruct HFC-134a. Meanwhile, a series of experiments were carried out in the combustion system. The effects of operation parameters such as excess air ratio, type of flame (Premixed flame and Premixed-diffusive flame) and HFC-134a/LPG on the HFC-134a decomposition efficiency were also investigated. The experimental results indicated that a maximum HFC-134a decomposition efficiency of 99.98% was achieved when excess air ratio was above 0.9 and HFC-134/LPG was below 0.8 in the premixed diffusive flame. Meanwhile, the excess air ratio and HFC-134a/LPG ratio had a significant impact on the HFC-134a destruction efficiency. Moreover, the premixed flame was better than the premixed-diffusive flame for decomposing HFC-134a. Although HFC-134a decomposition efficiency was as high as 98.5%, there were still some byproducts such as C2H2F2, CHF3 and C2H3F in the flue gas, which was proven by gas chromatography mass spectrometry analyzer (GC-MS).
引用
下载
收藏
页码:1919 / 1923
页数:5
相关论文
共 50 条
  • [41] Coexistence curve of HFC-134a and thermal conductivity of HFC-245fa
    Yata, J
    Hori, M
    Niki, M
    Isono, Y
    Yanagitani, Y
    FLUID PHASE EQUILIBRIA, 2000, 174 (1-2) : 221 - 229
  • [42] HFC-134a制冷剂冰箱维修
    刘胜
    家庭电子, 2005, (02) : 24 - 24
  • [43] COMPARISON OF THE REFRIGERANTS HFC-134A AND CFC-12
    PETERSSON, B
    THORSELL, H
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1990, 13 (03): : 176 - 180
  • [44] LIQUID VISCOSITIES AND DENSITIES OF HFC-134A + GLYCOL MIXTURES
    KUMAGAI, A
    MOCHIDA, H
    TAKAHASHI, S
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1993, 14 (01) : 45 - 53
  • [45] Thermal Conductivity of HFC-32, HFC-125, and HFC-134a in the Solid Phase
    X. Gao
    Y. Nagasaka
    A. Nagashima
    International Journal of Thermophysics, 1998, 19 : 415 - 425
  • [47] HFC-134a预热器失效分析
    淡勇
    化工机械, 2010, 37 (01) : 103 - 106
  • [48] Measurements of the Thermal Conductivity of HFC-134a in the Supercritical Region
    Le Neindre, B.
    Garrabos, V.
    Gumerov, F.
    Sabirzianov, A.
    JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2009, 54 (09): : 2678 - 2688
  • [49] Thermal conductivity of HFC-32, HFC-125, and HFC-134a in the solid phase
    Gao, X
    Nagasaka, Y
    Nagashima, A
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 1998, 19 (02) : 415 - 425
  • [50] Thermodynamic properties and cooling cycles of HFC-134a, HFC-152a, and their mixtures
    Dobrokhotov, AV
    Ustjuzhanin, EE
    Reutov, BF
    Testov, AG
    Utenkova, NA
    HIGH TEMPERATURES-HIGH PRESSURES, 1999, 31 (04) : 375 - 380