Left ventricular assist device bioinformatics identify possible hubgenes and regulatory networks involved in the myocardium of patients with left ventricular assist device

被引:0
|
作者
Ajmal, Maryam [1 ]
Ajmal, Aisha [2 ]
Rizvi, Maryam [1 ]
Salim, Umar [2 ]
Huang, Lei [3 ,4 ,5 ,6 ]
机构
[1] Kings Coll London, Fac Life Sci & Med, Guys Kings & St Thomas GKT Sch Med Educ, London, England
[2] St Georges Univ London, St Georges Hosp, Med Sch, London, England
[3] Tianjin Third Cent Hosp, Dept Heart Ctr, Tianjin, Peoples R China
[4] Tianjin Third Cent Hosp, Tianjin Key Lab Extracorporeal Life Support Crit D, Tianjin, Peoples R China
[5] Artificial Cell Engn Technol Res Ctr, Tianjin, Peoples R China
[6] Tianjin Inst Hepatobiliary Dis, Tianjin, Peoples R China
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2022年 / 9卷
关键词
heart failure; metabonomics; differentially expressed genes; left ventricular assist device; bioinformatic; CELL-DERIVED FACTOR-1; HEART-FAILURE; PROSTAGLANDIN E-2; GROWTH-FACTOR; SUPPORT; MORTALITY; EXPRESSION; PATTERNS; RECOVERY; RECEPTOR;
D O I
10.3389/fcvm.2022.912760
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
ObjectiveThe aim of this study was to clarify the changes of myocardial gene expression profile after left ventricular assist device (LVAD) implantation and the related molecular biological significance. MethodsA thorough bioinformatic analysis to evaluate the changes in gene expression profile in patients pre-LVAD and post-LVAD was conducted. Four relevant gene expression datasets-GSE430, GSE974, GSE21610, and GSE52601 from Gene Expression Omnibus (GEO) database were downloaded. Analysis of GEO2R, Gene Ontology (GO), protein-protein interaction (PPI) were used to determine differentially expressed genes (DEGs) and their function, respectively. ResultsA total of 37 DEGs were identified, including 26 down-regulated and 11 up-regulated genes. The molecular function of DEGs were enriched in "cytokine activity," "neurotransmitter binding," "receptor ligand activity." The gene set enrichment analysis (GSEA) revealed an overall marked increase of neutrophil degranulation signaling, closely correlated with the G protein coupled receptor (GPCR)-ligand binding process after LVAD assistance. 16 hubgenes in these DEGs were further selected and the biological process involved is mainly related to positive regulation of leukocyte chemotaxis mediated by chemokines. ConclusionInflammatory signaling pathway is crucial for the pathophysiology after LVAD implantation. Chemokines mediate cardiac inflammatory response and tissue remodeling after LVAD implantation through GPCR-ligand binding.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Initial Experience of Conversion of Toyobo Paracorporeal Left Ventricular Assist Device to DuraHeart Left Ventricular Assist Device
    Yoshioka, Daisuke
    Sakaguchi, Taichi
    Saito, Shunsuke
    Miyagawa, Shigeru
    Nishi, Hiroyuki
    Yoshikawa, Yasushi
    Fukushima, Satsuki
    Ueno, Takayoshi
    Kuratani, Toru
    Sawa, Yoshiki
    CIRCULATION JOURNAL, 2012, 76 (02) : 372 - 376
  • [22] Impact of perioperative right ventricular assist device on ventricular arrhythmias in patients with continuous flow left ventricular assist device
    Dhawan, R.
    Selim, A.
    Jhand, A.
    Lundgren, S.
    Zolty, R.
    Khan, F.
    EUROPEAN HEART JOURNAL, 2020, 41 : 1096 - 1096
  • [23] Device Thrombosis in the HeartWare Left Ventricular Assist Device
    Siddique, Aleem
    Wrightson, Neil
    Macgowan, Guy A.
    Schueler, Stephan
    ANNALS OF THORACIC SURGERY, 2013, 95 (04): : 1508 - 1508
  • [24] Platelet function in patients with a left ventricular assist device
    Ashbrook, M.
    Schwatz, J.
    Heroux, A.
    Escalante, V
    Jeske, W.
    Walenga, J.
    Bakhos, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 344 - 344
  • [25] Ventricular Arrhythmias After Left Ventricular Assist Device
    Nakahara, Shashima
    Chien, Christopher
    Gelow, Jill
    Dalouk, Khidir
    Henrikson, Charles A.
    Mudd, James
    Stecker, Eric C.
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03): : 648 - 654
  • [26] Ventricular Standstill in a Patient With a Left Ventricular Assist Device
    Fukunaga, Naoto
    Nedadur, Rashmi
    Badiwala, Mitesh V.
    Billia, Filio
    McDonald, Michael A.
    Rao, Vivek
    ANNALS OF THORACIC SURGERY, 2019, 108 (03): : E153 - E155
  • [27] Left Ventricular Assist Device in Right Ventricular Failure
    Parwani, P.
    Gowd, B. M. P.
    Nahar, R.
    Statz, C.
    O'Sullivan, D.
    Chomick, N.
    Radojevic, J.
    Gluck, J.
    Hammond, J.
    Wencker, D.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (04): : S83 - S83
  • [28] Alarms and Their Outcomes in Left Ventricular Assist Device Patients
    Lim, Zi Z.
    Robson, Desiree
    Muthiah, Kavitha
    Jansz, Paul
    Macdonald, Peter S.
    Hayward, Christopher S.
    ASAIO JOURNAL, 2021, 67 (12) : 1284 - 1293
  • [29] Tricuspid regurgitation in left ventricular assist device patients
    Westaby, Stephen
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 41 (01) : 217 - 218
  • [30] Antiphospholipid Syndrome in Patients with Left Ventricular Assist Device
    Al-Naamani, A.
    Meyer, A. L.
    Jawad, K.
    Fischer, J.
    Siegemund, A.
    Siegemund, T.
    Oberbach, A.
    Hahn, J.
    Lehmann, S.
    Mohr, F. W.
    Garbade, J.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2017, 36 (04): : S251 - S251