Spoiled FLASH MRI with Slice Selective Excitation: Signal Equation with a Correction Term

被引:16
|
作者
Gras, Vincent [1 ]
Abbas, Zaheer [1 ]
Shah, Nadim J. [1 ,2 ]
机构
[1] Res Ctr Julich, Inst Neurosci & Med, Med Imaging Phys INM 4, D-52425 Julich, Germany
[2] Rhein Westfal TH Aachen, Dept Neurol, Fac Med, JARA, D-52074 Aachen, Germany
关键词
quantitative imaging; slice profile correction; T1; proton density; LEFT-VENTRICULAR FUNCTION; DISPLACEMENT-ENCODED MRI; MECHANICAL-PROPERTIES; MYOCARDIAL MECHANICS; STIMULATED ECHOES; MOTION; HEART; DENSE; STRAIN; CINE;
D O I
10.1002/cmr.a.21264
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Spoiled fast low-angle shot (FLASH) magnetic resonance imaging (MRI) provides a simple contrast, largely independent of the spin-spin relaxation time. Three-dimensional FLASH imaging (3D FLASH) has gained importance due to its simplicity and its ability to produce isotropic, high-resolution images. Nevertheless, 2D FLASH imaging can be more suited than 3D FLASH imaging in various specific applications requiring long repetition time, such as imaging of the proton density (PD), as it allows interleaved slice acquisition rather than consecutive slice acquisition. In practice, however, a slice-selective excitation produces a nonuniform excitation profile, which needs to be taken into account to allow reliable quantitative data analysis. In this work, the influence of the nonuniform excitation profile on the detected signal is modeled as a dimensionless multiplicative correction, function of the flip angle, and the ratio of the repetition time to the spin-lattice relaxation time (T-1). This model is validated experimentally by measuring the PD and T-1 MR parameters in a phantom experiment on a 3T clinical scanner. A good accuracy in the estimation of T-1 and in the reconstruction of the PD (weighted by the receiver sensitivity profile) is obtained, for example, a relative error of 3% in T-1 within the range [500, 2000] ms and a precision of 1% in PD. It is also shown how the proposed theory can be extended to magnetization-prepared 2D-spoiled FLASH as well as other variations of the 2D-spoiled FLASH sequence. (C) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:89 / 100
页数:12
相关论文
共 6 条
  • [1] Exact algebraization of the signal equation of spoiled gradient echo MRI
    Dathe, Henning
    Helms, Gunther
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4231 - 4245
  • [2] Sparsity-enforced slice-selective MRI RF excitation pulse design
    Zelinski, Adam C.
    Wald, Lawrence L.
    Setsompop, Kawin
    Goyal, Vivek K.
    Adalsteinsson, Elfar
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2008, 27 (09) : 1213 - 1229
  • [3] Myocardial T1 Mapping at 3.0 Tesla Using an Inversion Recovery Spoiled Gradient Echo Readout and Bloch Equation Simulation with Slice Profile Correction (BLESSPC) T1 Estimation Algorithm
    Shao, Jiaxin
    Rapacchi, Stanislas
    Kim-Lien Nguyen
    Hu, Peng
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 43 (02) : 414 - 425
  • [4] Quantitative 19F MRI of perfluoro-15-crown-5-ether using uniformity correction of the spin excitation and signal reception
    Vernikouskaya, Ina
    Pochert, Alexander
    Linden, Mika
    Rasche, Volker
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2019, 32 (01) : 25 - 36
  • [5] Quantitative 19F MRI of perfluoro-15-crown-5-ether using uniformity correction of the spin excitation and signal reception
    Ina Vernikouskaya
    Alexander Pochert
    Mika Lindén
    Volker Rasche
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2019, 32 : 25 - 36
  • [6] Reducing metallic artefacts in post-operative spinal imaging: slice encoding for metal artefact correction with dual-source parallel radiofrequency excitation MRI at 3.0 T
    Song, K. D.
    Yoon, Y. C.
    Park, J.
    BRITISH JOURNAL OF RADIOLOGY, 2013, 86 (1027):